Skip to content

Intraoperative Optic Nerve Sheath Diameter Changes After Laparoscopic Surgery

Ultrasonographic Evaluation of Intraoperative Optic Nerve Sheath Diameter Changes in Patients Undergoing Laparoscopic Surgery

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06209034
Enrollment
55
Registered
2024-01-17
Start date
2023-12-30
Completion date
2024-09-15
Last updated
2026-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Pressure Increase, Optic Nerve Sheath Diameter

Keywords

Ultrasonography, Optic nerve sheath diameter, Laparoscopic surgery

Brief summary

Laparoscopic surgery is a widely used alternative to open surgery; Advantages include reduced bleeding and pain intensity, shorter hospital stay, and improved cosmetic results. Laparoscopic surgery involves the creation of a carbon dioxide (CO2) pneumoperitoneum to facilitate a clear surgical view, which can result in increased intracranial pressure (ICP). Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is a simple, non-invasive, yet reliable technique for ICP assessment.Ultrasonographic assessment of optic nerve sheath diameter (ONSD) has been proposed as a non-invasive measurement of intracranial pressure.

Detailed description

Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is a simple, non-invasive, yet reliable technique for ICP assessment. Previous studies have demonstrated that ultrasonographic measurement of ONSD correlates with the degree of ICP and can detect intracranial hypertension in a variety of clinical settings. It was planned to measure the optic nerve sheath throughout the surgery with the help of a linear ultrasound probe. Ultrasonographically, in each measurement, the optic nerve sheath diameter (ONSD) was detected 3 mm behind the entry point of the optic nerve into the globe in both eyes. ONSD will be measured bilaterally 3 mm behind the papilla. It will be evaluated by transverse measurement for each optic nerve.

Interventions

ONSD was measured bilaterally 3 mm posterior to the papilla. Transverse measurements were made for each optic nerve.

Sponsors

Kocaeli University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

Single(Participant)

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* 18-75 aged patients * American Society of Anesthesiologists Classification (ASA) I-II-III patients * Patients undergoing laparoscopic surgery

Exclusion criteria

* American Society of Anesthesiologists Classification (ASA) IV-V patients * Those with known ophthalmic disease * Those with a history of ophthalmic surgery * Those with any known neurological disorder * History of intracranial hypertension * Patients who will undergo open abdominal surgery

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of optic nerve sheath diameterDuring the operationUltrasound measurement of optic nerve sheath diameter during laparoscopic surgery

Countries

Turkey (Türkiye)

Contacts

STUDY_DIRECTORSevim Cesur

Kocaeli University

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 19, 2026