Skip to content

Gastro-intestinal Biopotential Recorder by Means of Surface ELEctrodes

Gastro-intestinal Biopotential Recorder by Means of Surface ELEctrodes

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06197334
Acronym
GRELE
Enrollment
60
Registered
2024-01-09
Start date
2025-02-18
Completion date
2027-09-01
Last updated
2026-06-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Crohn Disease, Functional Gastrointestinal Disorders, Healthy

Keywords

Medical device, Electrophysiology

Brief summary

The goal of this clinical trial is to compare the gastro-intestinal biopotentials recorded with a homemade device using surface electrodes placed on the abdomen in healthy volunteers, Crohn's disease patients without fibrosis, Crohn's disease patients with fibrosis and in functional gastrointestinal disorders (FGID) patients. The main question it aims to answer is: • Is there any differences in the gastro-intestinal biopotentials between the different populations under study? It aims to answer two secondary questions: * Are the gastro-intestinal biopotentials comparable to the Harvey-Bradshaw Index, MRI and biological data for patients with Crohn's disease? * Are the gastro-intestinal biopotentials comparable to Rome IV criteria for functional gastrointestinal disorders patients? Participants will undertake two recordings made with the device. The first one will last 1 hour and 30 minutes and will occurs while the participants are fasting. Then, the participants will eat a standardized meal. Finally, the second recording will take place after the meal ingestion and will last 1 hour and 30 minutes while the participants are in postprandial state.

Detailed description

Diseases and disorders of the digestive tract affect a large proportion of the world's population. These disorders or diseases degrade patients' quality of life and are costly for healthcare systems. Today, it is difficult to categorize, monitor and/or prognosticate their evolution due to their unknown etiologies, the long duration of the digestion processes and unsuitable (invasive, complex or costly) examinations. However, electrophysiology holds great promise for the study of these diseases. Indeed, the organs of the digestive tract are made up of longitudinal and circular muscles which contract rhythmically and synchronously to advance the food bolus during digestion, or to cleanse the digestive tract once digestion is complete. No study has yet demonstrated the feasibility and value of measuring these bio-potentials for Functional Gastro Intestinal Disorders and Inflammatory Bowel Diseases. That's why a homemade gastro-intestinal biopotentials recorder was developped. The recorder uses surface electrodes placed on the abdomen to record this biopotentials. The investigators hypothesize that surface gastro-intestinal biopotentials differ between a population of healthy volunteers, Crohn's disease patients and FGID patients.

Interventions

DEVICEGastro-intestinal biopotentials recording

Participants will undertake two recordings made with the device. The first one will last 1 hour and 30 minutes and will occurs while the participants are fasting. Then, they will eat a standardized meal. Finally, the second recording will take place after the meal ingestion and will last 1 hour and 30 minutes while the participants are in postprandial state.

Sponsors

Central Hospital, Nancy, France
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

for all participants: * Person age \> 18 years * Person has been fasting for at least 12 hours * Person who has received full information on the organization of the research and has not objected to the use of this data. * Person affiliated to or beneficiary of a social security plan * Person informed about study organization and having signed the informed consent Inclusion Criteria for healthy volunteers : * Person has no history of chronic gastro-intestinal disease * Person has no acute of gastro-intestinal disease Inclusion Criteria for Crohn's disease patients without fibrosis : * Person is already diagnosed with Crohn's disease * Person has underwent during the last 6 months : * An MRI showing no fibrosis * A blood test for C-reactive protein and fecal calprotectine * A questionnaire to asses the Harvey-Bradshaw Index Inclusion Criteria for Crohn's disease patients with fibrosis : * Person is already diagnosed with Crohn's disease * Person has underwent during the last 6 months : * An MRI showing fibrosis * A blood test for C-reactive protein and fecal calprotectine * A questionnaire to asses the Harvey-Bradshaw Index Inclusion Criteria for functional gastrointestinal disorders patients : * Person is already diagnosed with functional gastrointestinal disorders * Person has underwent an evaluation of the Rome IV criteria

Exclusion criteria

for all participants: * Person having a pacemaker * Person suffering from a sensory disorder making insensitive to pain on the skin * Person suffering from a mental or motor disorders creating uncontroled movements * Person being allergic to one or more component of the device * Person being allergic to : soy, dairy food, peanuts, wheat, nuts * Person having an history of gastro-intestinal surgery * Person suffering from injury or erythema on the abdominal skin * Person having a contagious potential (bacterial, fungal or viral) * Person being in menstruation period * Person suffering from urinary incontinence * Minor (not emancipated) * Person of legal age (subject to a legal protection measure) * Adult unable to give consent

Design outcomes

Primary

MeasureTime frameDescription
Gastro-intestinal biopotentials pattern as recorded by the homemade recorder12 monthsGastro-intestinal biopotentials pattern in patients versus healthy volunteers

Secondary

MeasureTime frameDescription
Correlation score between gastro-intestinal biopotentials pattern as recorded by the homemade recorder vs Harvey-Bradshaw Index assessed with a questionnaire12 monthsCorrelation score in Crohn's disease patients with and without fibrosis for the gastro-intestinal biopotentials pattern vs the Harvey-Bradshaw Index
Correlation score between gastro-intestinal biopotentials pattern as recorded by the homemade recorder vs the Nancy score assessed by a clinician rating MRI images12 monthsCorrelation score in Crohn's disease patients with and without fibrosis for the gastro-intestinal biopotentials pattern vs the Nancy score (MRI score)
Correlation score between gastro-intestinal biopotentials pattern as recorded by the homemade recorder vs blood fecal calprotectin levels (µg/g)12 monthsCorrelation score in Crohn's disease patients with and without fibrosis for the gastro-intestinal biopotentials pattern vs blood fecal calprotectin levels
Correlation score between gastro-intestinal biopotentials pattern as recorded by the homemade recorder vs C-reactive protein levels (µg/L)12 monthsCorrelation score in Crohn's disease patients with and without fibrosis for the gastro-intestinal biopotentials pattern vs C-reactive protein levels
Correlation score between gastro-intestinal biopotentials pattern as recorded by the homemade recorder vs Rome IV criteria12 monthsCorrelation score in functional gastrointestinal disorders patients for the gastro-intestinal biopotentials pattern vs the Rome IV criteria

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 25, 2026