Skip to content

Localization of Vasculonervous Structures in Tibial Nerve Neuromodulation: a Cross-sectional Study

Localization of Vasculonervous Structures in Tibial Nerve Neuromodulation: a Cross-sectional Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06196112
Enrollment
105
Registered
2024-01-09
Start date
2024-01-15
Completion date
2024-07-15
Last updated
2024-08-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Volunteers, Tibial Nerve

Keywords

tibial arteries, ultrasonography, Pelvic Floor Disorders, Transcutaneous Electric Nerve Stimulation

Brief summary

Tibial nerve neuromodulation is an effective and widely used technique in various pelvic floor dysfunctions. There are two approaches described in scientific literature to perform this technique: transcutaneous and percutaneous. However, there is no consensus on the execution of these techniques, as the location of the tibial nerve in relation to other anatomical structures like the tibia has not been described. The findings of this research could serve as a basis for the implementation and development of protocols aimed at improving the technique of posterior tibial neuromodulation.

Detailed description

Design: A cross-sectional observational study at the Physiotherapy Unit of the Ramón y Cajal University Hospital. The main objective of this study is to determine the location and size of tibial vasculonervous structures (nerve, artery, and vein) in relation to the tibia and skin using ultrasound in healthy subjects Methods: Healthy subjects will participate, and sociodemographic data (age, sex, weight, height) will be collected. Subsequently, various measurements of the right tibial vasculonervous structures will be obtained through ultrasound A single examiner with over 5 years of experience in ultrasound will perform the measurements. Significance of the research: Knowledge of the position and size of the tibial vasculonervous bundle could be useful to justify and standardize transcutaneous and percutaneous approaches in tibial nerve neuromodulation. This would improve the safety of the technique, avoiding adverse events resulting from the intervention

Interventions

None listed

Sponsors

Fundacion para la Investigacion Biomedica del Hospital Universitario Ramon y Cajal
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Healthy subjects over 18 years of age

Exclusion criteria

* Previous fracture of the distal end of the right tibia * Previous vascular pathology of the distal end of the right tibia * Previous nervous condition of the distal end of the right tibia * Previous surgical intervention of the distal end of the right tibia * Ongoing oncological process of the distal end of the right tibia

Design outcomes

Primary

MeasureTime frameDescription
Tibial Distance (TD) to the tibial nerveDay 1Subjects will be placed in a right lateral decubitus position on a bed. Seven marks will be made with a dermal marker from the lower edge of the right tibial malleolus, following the medial edge of the tibial bone in the cranial direction. Measurements will be taken at 2, 4, 5, 6, 8, 10, and 12 cm with respect to the lower edge of the tibial malleolus. The most superficial aspect of the tibia will be considered for the measurements. The measurements will be performed using an ultrasound machine (ALPINIONⓒ, Seoul, South Korea, model ECUBE 8LEⓇ) with a linear probe L3-12T (frequency range 3-12 MHz), using the Rehabilitative Ultrasound Imaging (RUSI) method. The distance will be measured using a caliper by drawing a straight line from the most medial aspect of the tibia to the most anterior aspect of the nerve, taking into consideration the outer edge of the tibial nerve wall. This will be analyzed at each of the 7 marks previously described
Tibial Distance (TD) to the tibial arteryDay 1Subjects will be placed in a right lateral decubitus position on a bed. Seven marks will be made with a dermal marker from the lower edge of the right tibial malleolus, following the medial edge of the tibial bone in the cranial direction. Measurements will be taken at 2, 4, 5, 6, 8, 10, and 12 cm with respect to the lower edge of the tibial malleolus. The most superficial aspect of the tibia will be considered for the measurements. The measurements will be performed using an ultrasound machine (ALPINIONⓒ, Seoul, South Korea, model ECUBE 8LEⓇ) with a linear probe L3-12T (frequency range 3-12 MHz), using the Rehabilitative Ultrasound Imaging (RUSI) method. The distance will be measured using a caliper by drawing a straight line from the most medial aspect of the tibia to the most anterior aspect of the artery, taking into consideration the outer edge of the tibial artery wall. This will be analyzed at each of the 7 marks previously described
Tibial Distance (TD) to the tibial veinDay 1Subjects will be placed in a right lateral decubitus position on a bed. Seven marks will be made with a dermal marker from the lower edge of the right tibial malleolus, following the medial edge of the tibial bone in the cranial direction. Measurements will be taken at 2, 4, 5, 6, 8, 10, and 12 cm with respect to the lower edge of the tibial malleolus. The most superficial aspect of the tibia will be considered for the measurements. The measurements will be performed using an ultrasound machine (ALPINIONⓒ, Seoul, South Korea, model ECUBE 8LEⓇ) with a linear probe L3-12T (frequency range 3-12 MHz), using the Rehabilitative Ultrasound Imaging (RUSI) method. The distance will be measured using a caliper by drawing a straight line from the most medial aspect of the tibia to the most anterior aspect of the vein, taking into consideration the outer edge of the tibial vein wall. This will be analyzed at each of the 7 marks previously described

Secondary

MeasureTime frameDescription
Depth of the tibial nerveDay 1Using the ultrasound machine and considering a caliper perpendicular from the most superficial aspect of the skin to the most superficial aspect of the epineurium at each of the 7 previously described marks
Cross-sectional area of the tibial nerveDay 1The cross-sectional area of the nerve will be measured at each of the 7 marks described above using the ultrasound
Cross-sectional area of the tibial arteryDay 1The cross-sectional area of the artery will be measured at each of the 7 marks described above using the ultrasound
Horizontal Tibial Distance to the tibial nerveDay 1The horizontal distance will be collected by drawing a perpendicular line with the caliper from the most medial aspect of the tibia to the most anterior aspect of the nerve, taking into consideration the outer edge of the tibial nerve wall. The measurement will be taken at each of the 7 marks previously described. This measurement will allow for an extrapolation in the implementation of percutaneous techniques
Overlap between each structureDay 1The overlap between the tibial nerve, artery, and vein will be described at each of the 7 marks previously mentioned
Variability of the tibial vesselsDay 1The number of arteries and veins present will be recorded at each of the 7 marks previously described
Cross-sectional area of the tibial veinDay 1The cross-sectional area of the vein will be measured at each of the 7 marks described above using the ultrasound
Horizontal Tibial Distance to the tibial arteryDay 1The horizontal distance will be collected by drawing a perpendicular line with the caliper from the most medial aspect of the tibia to the most anterior aspect of the artery tibial, taking into consideration the outer edge of the tibial artery wall. The measurement will be taken at each of the 7 marks previously described. This measurement will allow for an extrapolation in the implementation of percutaneous techniques
Horizontal Tibial Distance to the tibial veinDay 1The horizontal distance will be collected by drawing a perpendicular line with the caliper from the most medial aspect of the tibia to the most anterior aspect of the vein, taking into consideration the outer edge of the tibial vein wall. The measurement will be taken at each of the 7 marks previously described. This measurement will allow for an extrapolation in the implementation of percutaneous techniques

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026