Skip to content

F15 Recharge Free Axonics SNM System Clinical Study

Prospective, Non-randomized, Multicenter Clinical Evaluation of the Recharge Free Axonics SNM System (Model 4101)

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06186765
Enrollment
144
Registered
2024-01-02
Start date
2023-12-08
Completion date
2027-12-01
Last updated
2026-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fecal Incontinence (FI), Urinary Frequency (UF), Urinary Urge Incontinence (UUI)

Brief summary

Multicenter, prospective, non randomized, single arm evaluation of patients with overactive bladder (OAB) and/or fecal incontinence (FI) employing the Axonics recharge free SNM System.

Detailed description

A clinical evaluation to comply with new European Medical Device Regulations (EU MDR) guidelines. Multicenter, prospective, non-randomized, single arm study for OAB and/or FI to assess the safety and performance of the Food and Drug Administration (FDA) approved Axonics recharge free sacral neuromodulation (SNM) System, INS Model 4101. The product is currently marketed under the name F15.

Interventions

DEVICEAxonics SNM System (Model 4101)

Safety and performance/effectiveness assessment of the recharge free Axonics SNM System (Model 4101 in participants with overactive bladder (OAB) or fecal incontinence (FI).

Sponsors

Axonics, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. 18 years or older 2. Primary indication of overactive bladder (OAB) (urinary urgency incontinence (UUI)/ urinary frequency (UF)) or fecal incontinence (FI) who are not candidates for, or who have failed conservative treatment 3. Willing and capable to provide written informed consent and agrees to comply with specified evaluations at clinical investigational sites and attend all follow-up assessments for up to 1 year.

Exclusion criteria

1. Any significant medical condition that is likely to interfere with procedures, device operation, or likely to confound evaluation of endpoints (exclusion of neurological conditions such as multiple sclerosis) 2. Any psychiatric or personality disorder that is likely to interfere with procedures at the discretion of the participating physician; this may include poor understanding or compliance with requirements 3. Previously underwent an external sacral neuromodulation (SNM) trial and was deemed a non-responder or was previously implanted with a sacral neuromodulation device and did not get therapeutic benefit (a non-responder) 4. History of allergic response to titanium, zirconia, polyurethane, epoxy, or silicone 5. A female who is breastfeeding 6. A female with a positive urine pregnancy test

Design outcomes

Primary

MeasureTime frameDescription
Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)3 monthsInternational Consultation on Incontinence Questionnaire Overactive Bladder Quality of Life (ICIQ-OABqol): questions in each subscale are scored by a summed range of 0 to 100, with a higher score indicating better quality of life. Overall score ≥ 10 points from baseline to follow-up is indicative of a clinically meaningful improvement.
Performance/Effectiveness - Improvement in Fecal Incontinence Survey3 monthsCleveland Clinic Florida - Fecal Incontinence Score (CCF-FIS): includes 5 items (solid, liquid, gas, wears pad and lifestyle alteration) and 5 frequencies (never = 0, rarely = 1, sometimes = 2, usually = 3, always = 4). Scores range from 0 for full continence to 20 for complete incontinence. A higher score is indicative of the severity of fecal incontinence.
Adverse event reporting (Safety)3 monthsDevice-related, procedure-related and all serious adverse events

Secondary

MeasureTime frameDescription
Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)1 yearInternational Consultation on Incontinence Questionnaire Overactive Bladder Quality of Life (ICIQ-OABqol): questions in each subscale are scored by a summed range of 0 to 100, with a higher score indicating better quality of life. Overall score ≥ 10 points from baseline to follow-up is indicative of a clinically meaningful improvement.
Performance/Effectiveness - Improvement in Fecal Incontinence Survey1 yearCleveland Clinic Florida - Fecal Incontinence Score (CCF-FIS): includes 5 items (solid, liquid, gas, wears pad and lifestyle alteration) and 5 frequencies (never = 0, rarely = 1, sometimes = 2, usually = 3, always = 4). Scores range from 0 for full continence to 20 for complete incontinence. A higher score is indicative of the severity of fecal incontinence.
Performance/Effectiveness - Improvement in Quality of Life Survey (FI)3 months, 6 months, 1 yearFecal Incontinence Quality of Life (FIQoL): includes four different subscales: lifestyle, coping/behavior, depression/self-perception and embarrassment. Subscale scores range from 1 to 5, with 1 indicating lower functional status of qualify of life.
Adverse event reporting (Safety)1 yearDevice-related, procedure-related and all serious adverse events

Countries

Netherlands, United Kingdom, United States

Contacts

PRINCIPAL_INVESTIGATORProf. Bertil Blok, MD, PhD

Erasmus Medical Center

STUDY_DIRECTORGita Ghadimi, OD

Boston Scientific Corporation

Outcome results

None listed