Brain Diseases, Vertebral Artery Stenosis, Vertebral Artery Thrombosis
Conditions
Brief summary
Aprospective, multicentre, single-arm clinical trial in which approximately 36 subjects would be enrolled using the Bridge 4.5 mm and 5.0 mm stent in accordance with the inclusion and exclusion criteria in this protocol. The success rate of immediate post-procedure stent target lesion treatment was recorded for all subjects, and the incidence of in-stent restenosis (≥50% stenosis) was assessed by DSA imaging follow-up at 6 months (±30 days) post-procedure. The subjects were also followed up at 30 days (±7 days), 6 months (±30 days), and 12 months (±60 days) after stent implantation to assess safety events during the follow-up period. .
Interventions
Stent implantation
Sponsors
Study design
Eligibility
Inclusion criteria
* Aged 18 years or above (including 18 years old), 80 years old below (including 80 years old), male or women with pregnancy test (-); 2. Symptomatic vertebral artery stenosis patients who have failed in medical treatment (defined as patients who have suffered from stroke or TIA within 90 days, and are taking at least one antithrombotic drugs as well as interventions in other vascular risks, such as hypertension and hyperlipidemia decompression or lipid reducing); 3. DSA angiography showed target lesion stenosis degree ≥70% (Stenosis degrees are determined according to WASID method); 4. Diameter of normal blood vessels distal to the target lesion ≥3.5mm and the length of target lesion ≤23mm; 5. Modified Rankin score \<3; 6. Patients who are suitable for implantation of rapamycin target eluting vertebral artery stent and are voluntary to
Exclusion criteria
* Presence of tandem stenotic lesions (≥50% tandem stenosis) in the target lesion area; (2) TIA or non-disabling stroke due to factors other than vertebral artery stenosis (e.g. atrial fibrillation, etc.); (3) Previous surgical treatment or endovascular intervention in the target lesion area; (4) Comorbid severe systemic systemic diseases or other diseases with a potential risk of sudden death, or subjects with a life expectancy of \<1 year; (5) Subjects with contraindications to heparin, aspirin, clopidogrel, or other antiplatelet drugs and who cannot tolerate anticoagulant and antiplatelet drug therapy; (6) Previous cerebral infarction with residual responsible vascular-related severe neurological deficits (mRS ≥3 points); (7) Previous severe myocardial infarction within 2 weeks; (8) Accompanied by other intracranial lesions such as intracranial haemorrhage, aneurysm, arteriovenous malformation, intracranial tumour, etc (9) Non-atherosclerotic stenosis such as arterial entrapment, smoker's disease, active arteritis, and unknown causes; (10) Severe tortuosity or calcification of the target vessel that precludes implantation of a stent or lesion that cannot be dilated; (11) Severe renal impairment, or those who are allergic or resistant to contrast agents, rapamycin (Rapamycin) and its derivatives, cobalt-based alloys, PDLLA; (12) Pregnant or lactating women; (13) Patients participating in other drug or device studies that have not met endpoints
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Incidence of in-stent restenosis at 6 months postoperatively | 180±30 days |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Technical Success | post-implantation immediately | DSA suggesting residual stenosis ≤20% after implantation |
| Any death or stroke during the follow-up associated with treatment in the target vessel supply region | 1 year after stent implantation | Number of participants with death or stroke related to treatments for target vessel blood supply area |
| Any death or stroke | 1 year after stent implantation | Number of participants with death or stroke |
Countries
China