Skip to content

A PROSPECTIVE, MULTICENTER, SINGLE-ARM TRIAL FOR THE NEW SIZES OF BRIDGE STENTS FOR VERTEBRAL ARTERY STENOSIS: Bridge-MAX

A PROSPECTIVE, MULTICENTER, SINGLE-ARM TRIAL FOR THE NEW SIZES OF BRIDGE STENTS FOR VERTEBRAL ARTERY STENOSIS: Bridge-MAX

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06186024
Enrollment
36
Registered
2023-12-29
Start date
2023-09-27
Completion date
2025-01-30
Last updated
2023-12-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Diseases, Vertebral Artery Stenosis, Vertebral Artery Thrombosis

Brief summary

Aprospective, multicentre, single-arm clinical trial in which approximately 36 subjects would be enrolled using the Bridge 4.5 mm and 5.0 mm stent in accordance with the inclusion and exclusion criteria in this protocol. The success rate of immediate post-procedure stent target lesion treatment was recorded for all subjects, and the incidence of in-stent restenosis (≥50% stenosis) was assessed by DSA imaging follow-up at 6 months (±30 days) post-procedure. The subjects were also followed up at 30 days (±7 days), 6 months (±30 days), and 12 months (±60 days) after stent implantation to assess safety events during the follow-up period. .

Interventions

DEVICEBridge

Stent implantation

Sponsors

MicroPort NeuroTech Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Aged 18 years or above (including 18 years old), 80 years old below (including 80 years old), male or women with pregnancy test (-); 2. Symptomatic vertebral artery stenosis patients who have failed in medical treatment (defined as patients who have suffered from stroke or TIA within 90 days, and are taking at least one antithrombotic drugs as well as interventions in other vascular risks, such as hypertension and hyperlipidemia decompression or lipid reducing); 3. DSA angiography showed target lesion stenosis degree ≥70% (Stenosis degrees are determined according to WASID method); 4. Diameter of normal blood vessels distal to the target lesion ≥3.5mm and the length of target lesion ≤23mm; 5. Modified Rankin score \<3; 6. Patients who are suitable for implantation of rapamycin target eluting vertebral artery stent and are voluntary to

Exclusion criteria

* Presence of tandem stenotic lesions (≥50% tandem stenosis) in the target lesion area; (2) TIA or non-disabling stroke due to factors other than vertebral artery stenosis (e.g. atrial fibrillation, etc.); (3) Previous surgical treatment or endovascular intervention in the target lesion area; (4) Comorbid severe systemic systemic diseases or other diseases with a potential risk of sudden death, or subjects with a life expectancy of \<1 year; (5) Subjects with contraindications to heparin, aspirin, clopidogrel, or other antiplatelet drugs and who cannot tolerate anticoagulant and antiplatelet drug therapy; (6) Previous cerebral infarction with residual responsible vascular-related severe neurological deficits (mRS ≥3 points); (7) Previous severe myocardial infarction within 2 weeks; (8) Accompanied by other intracranial lesions such as intracranial haemorrhage, aneurysm, arteriovenous malformation, intracranial tumour, etc (9) Non-atherosclerotic stenosis such as arterial entrapment, smoker's disease, active arteritis, and unknown causes; (10) Severe tortuosity or calcification of the target vessel that precludes implantation of a stent or lesion that cannot be dilated; (11) Severe renal impairment, or those who are allergic or resistant to contrast agents, rapamycin (Rapamycin) and its derivatives, cobalt-based alloys, PDLLA; (12) Pregnant or lactating women; (13) Patients participating in other drug or device studies that have not met endpoints

Design outcomes

Primary

MeasureTime frame
Incidence of in-stent restenosis at 6 months postoperatively180±30 days

Secondary

MeasureTime frameDescription
Technical Successpost-implantation immediatelyDSA suggesting residual stenosis ≤20% after implantation
Any death or stroke during the follow-up associated with treatment in the target vessel supply region1 year after stent implantationNumber of participants with death or stroke related to treatments for target vessel blood supply area
Any death or stroke1 year after stent implantationNumber of participants with death or stroke

Countries

China

Contacts

Primary ContactHuina Lu
HuiNa.Lu@microport.com15901703529

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026