Acute Respiratory Failure, Interstitial Lung Disease
Conditions
Keywords
Noninvasive mechanical ventilation, Nasal high-flow oxygen therapy, Respiratory work, Hemodynamics, Diaphragm
Brief summary
The objectives of this study are to compare the physiological consequences of high-flow oxygen therapy and noninvasive mechanical ventilation on ventilation, respiratory work and hemodynamics during acute respiratory failure in diffuse interstitial pneumonia.
Interventions
Noninvasive mechanical ventilation is a respiratory technique which allows the administration of positive inspiratory and expiratory airway pressures in order to ventilate the lungs.
Nasal high-flow is a respiratory technique which allows the administration of warmed and humidified air, associated with oxygen.
Continuous positive airway pressure is a respiratory technique which allows to maintain a constant positive airway pressure during inspiration and expiration.
Sponsors
Study design
Eligibility
Inclusion criteria
* Age \> 18 yrs * Hospitalization in intensive care unit * Acute exacerbation of a previously/presently documented diffuse (fibrotic) interstitial lung disease * Dyspnea majoration since at least 1 month * Alveolar or ground-glass opacities on CT-scan that are superposed to interstitial lung disease and not explained by left heart failure or volume overload * Hypoxemia requiring oxygen flows \> 6 L/min
Exclusion criteria
* Contraindication to noninvasive ventilation or high-flow oxygen therapy * Immediate indication to endotracheal intubation or hemodynamic assistance * Body mass index \> 40 * Presence of a pacemaker or an implantable defibrillator * Presence of cutaneous lesions where Pulmovista® belt should be placed * Moribund patient * Pregnant or breastfeeding women or women of childbearing age without an effective method of contraception * Protected adult patient (tutorship or curatorship) * Patient deprived of liberty by court or administrative decision * No possibility to install nasogastric tube * Endotracheal or tracheostomy tube requirement during the study * Hemodynamic assistance requirement during the study
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Pulmonary compliance | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of global pulmonary compliance (Cglob) under noninvasive ventilation (NIV) and high-flow oxygen therapy (HFO) during acute respiratory failure in diffuse interstitial pneumonia. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Tidal volume | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Tidal volume under CPAP and face mask oxygen therapy (FM) during acute respiratory failure in diffuse interstitial pneumonia. |
| end-expiratory lung volume | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of end-expiratory lung volume under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| transpulmonary pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of transpulmonary pressure under FM and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| driving pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of driving pressure under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| Global inhomogeneity index | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Global inhomogeneity index under CPAP and FM during acute respiratory failure in diffuse interstitial pneumonia. |
| respiratory rate | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of respiratory rate under HFO and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| inspiratory time | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of inspiratory time under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| oesophagal pressure swings | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of oesophagal pressure variations between inspiration and expiration under CPAP and HFO during acute respiratory failure in diffuse interstitial pneumonia. |
| transdiaphragmatic pressure variations | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of transdiaphragmatic pressure variations between inspiration and expiration under NIV and HFO during acute respiratory failure in diffuse interstitial pneumonia. |
| transdiaphragmatic pressure time products | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of transdiaphragmatic pressure time products under HFO and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| oesophagal pressure time products | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of oesophagal pressure time products under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| ultrasound diaphragmatic strain. | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of ultrasound diaphragmatic strain under HFO and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| diaphragmatic thickening fraction | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of diaphragmatic thickening fraction under HFO and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| peak inspiratory flow | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of peak inspiratory flow under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| peak expiratory flow | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of peak expiratory flow under FM and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| Pulmonary compliance | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of global pulmonary compliance (Cglob) under NIV and continuous positive airway pressure (CPAP) during acute respiratory failure in diffuse interstitial pneumonia. |
| Diastolic arterial pressures | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Diastolic arterial pressures under CPAP and HFO during acute respiratory failure in diffuse interstitial pneumonia. |
| Mean arterial pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Mean arterial pressures under HFO and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| systolic pulmonary arterial pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of systolic pulmonary arterial pressure under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
| tricuspid annular plane systolic excursion | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of tricuspid annular plane systolic excursion under CPAP and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| right ventricular strain | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of right ventricular strain under HFO and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| left ventricular ejection fraction | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of left ventricular ejection fraction under CPAP and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| E/E' ratio | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of E/E' ratio under HFO and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| right auricular pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of right auricular pressure under CPAP and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| cardiac output | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of cardiac output under HFO and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| heart rate | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of heart rate under CPAP and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| Pulsed oxymetry | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of pulsed oxymetry under NIV and HFO during acute respiratory failure in diffuse interstitial pneumonia. |
| transcutaneous carbon dioxide pressure | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of transcutaneous carbon dioxide pressure under CPAP and HFO during acute respiratory failure in diffuse interstitial pneumonia. |
| Dyspnea | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Borg's scale (from 0 to 10, 10 is maximal dyspnea) under HFO and FM during acute respiratory failure in diffuse interstitial pneumonia. |
| Comparison of Comfort | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Visual comfort scale (from 0 to 10, 10 is maximal confort) under FM and NIV during acute respiratory failure in diffuse interstitial pneumonia. |
| Systolic arterial pressures | During the intervention, after an exposure of 30 minutes to the oxygen therapy device | Comparison of Systolic arterial pressures under NIV and CPAP during acute respiratory failure in diffuse interstitial pneumonia. |
Countries
France