Skip to content

Surface Hardness and Wear Characteristics of Prefabricated and CAD/CAM Milled Artificial Teeth

Surface Hardness and Wear Resistance of Prefabricated and CAD/CAM Milled Artificial Teeth: A Cross-over Clinical Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06179615
Enrollment
10
Registered
2023-12-22
Start date
2022-06-10
Completion date
2023-09-13
Last updated
2023-12-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Surface Hardness and Wear Resistance of Artificial Teeth

Brief summary

Purpose: This study aimed to assess the 3-dimentional wear )3D) (volumetric loss) and 2-dimentional wear (2D) (vertical loss) and surface hardness of ready-made (prefabricated) and CAD/CAM milled artificial denture teeth. material and methods: In a cross-over study design, ten completely edentulous patients were randomly chosen for this study and given two complete dentures. The first complete denture was constructed with pre-fabricated teeth. The second complete denture was constructed with CAD\\CAM milled teeth. The complete denture teeth were 3D scanned at the time of insertion (T0), after three months (T3), and after six months (T6) of denture insertion. Utilizing 3D surface superimposition techniques, the vertical (2D wear), and Volumatic (3D wear) material loss were measured. The hardness of the teeth were evaluated at the time of denture insertion (T0) then after 6 months (T6) of denture insertion by Vickers hardness test. Statistical analysis was done using SPSS software. Paired groups were compared by paired t test. Significant difference was considered if P ≤ 0.05.

Interventions

OTHERsurface hardness test for denture teeth

surface hardness test of denture teeth at insertion then after 6 months of use

OTHERwear resistance of denture teeth measurement

2D, Vertical wear, 3D Volumetric wear were measured for denture teeth

Sponsors

Mansoura University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
55 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* completely edentulous * angle class I maxillomandibular relations

Exclusion criteria

* Angle's class II, III maxillomandibular relation * systemic disease that affect the bone and soft tissue health

Design outcomes

Primary

MeasureTime frameDescription
wear resistance of denture artificial teeth6 months after denture use2D, 3D wear of denture teeth were measured using denture scanning and superimposition of the sanning at insertion to that after 3, 6 months using Exocad soft ware
surface hardness of the denture artificial teeth6 months after denture usethe measurement of surface hardness was done using Vickers's test. this measurements was done at insertion then after 6 months

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026