Skip to content

Safety and Effectiveness of the Alma System in Treating Primary Postpartum Hemorrhage

Safety and Effectiveness of the Alma System in Treating Primary Postpartum Hemorrhage

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06166771
Enrollment
10
Registered
2023-12-12
Start date
2024-09-09
Completion date
2025-06-30
Last updated
2024-10-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Postpartum Hemorrhage \(PPH\), Postpartum Hemorrhage \(Primary\), PPH

Keywords

alma, pph, post partum hemorrhage

Brief summary

Postpartum Hemorrhage (PPH) is an obstetric emergency that can occur up to 24 hours after vaginal birth or cesarean section. In most cases, the uncontrolled bleeding is due to a lack of sufficient contraction of the uterus (hypotonia) and appears immediately after birth. The purpose of this prospective, non-randomized, feasibility pilot study is to obtain information on the safety and effectiveness of an investigational new medical device - Alma System, that is intended to provide control and treatment of abnormal postpartum uterine bleeding or hemorrhage when conservative management is warranted.

Detailed description

A prospective, non-randomized, feasibility pilot study that is intended to obtain information on the safety and effectiveness of the Alma System. Study population: Women with vaginal deliveries in a hospital setting who failed first-line therapies for postpartum hemorrhage. The main questions are: 1. Rate of device related SAEs up to six weeks following device treatment. 2. Rate of any observable damage to cervix, uterus or vagina during or immediately after device procedure. 3. Rate of occurrence of uterine inversion of folding during or immediately after device procedure. Main tasks for participants: * sign the informed Consent form and enrolment * In case of PPH, treatment with Alma * Participate in 2 follow-up visits After the treatment- 1st upon discharge and 2nd after 6 weeks.

Interventions

Subjects diagnosed with postpartum hemorrhage will receive the Alma System. This system comprises a soft silicone cylindrical device placed within the uterus. Gentle suction is applied, prompting the uterus to contract and reduce in size. This contraction compresses the blood vessels, halting the bleeding.

Sponsors

ResQ Medical Ltd
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Adult Female, 18 years of age or older at time of consent. 2. Subject or her legally authorized representative is able to understand and provide consent to participate in the clinical investigation. 3. Subjects who present with an atonic uterus for at least 10 minutes after expulsion of placement with failure to obtain contraction and/or Subjects who have lost blood post-partum \> = 500 ml and according to the Investigator's judgment, require an intervention. 4. Failed first-line intervention of uterotonics and uterine massage/bimanual uterine massage to stop bleeding.

Exclusion criteria

1. Subjects who do not provide informed consent to participate in the clinical investigation. 2. Subjects who deliver at a uterus size \< 34 weeks. 3. Subjects who have lost greater than 1000 ml of blood. 4. Subjects who have abnormal PT, PTT and INR 5. Subjects who present with retained placenta, uterine lacerations, or for any other conditions outside of atonic post-partum hemorrhage. 6. PPH that the investigator determines to require more aggressive treatment, including any of the following: * Hysterectomy; * B-lynch suture; * Uterine artery embolization or ligation; * Hypogastric ligation. * Known uterine anomaly. * Ongoing intrauterine pregnancy. 7. Placental abnormality including any of the following: * Known placenta accreta; * Retained placenta with known risk factors for placenta accreta (e.g., history of prior uterine surgery, including prior c-section and placenta previa); * Retained placenta without easy manual removal. 8. Known uterine rupture. 9. Unresolved uterine inversion.

Design outcomes

Primary

MeasureTime frameDescription
Rate of Related SAEs6 weeksRate of device related SAEs up to six weeks following device treatment.
Rate of Damage to Cervix, Uterus or VaginaWhen removing the Alma System at the end of the procedureRate of any observable damage to cervix, uterus or vagina during or immediately after device procedure
Rate of Occurrence of Uterine Inversion or FoldingWhen removing the Alma System at the end of the procedureRate of occurrence of uterine inversion or folding during or immediately after device procedure

Secondary

MeasureTime frameDescription
User Feedback on Placement of AlmaWhen removing the Alma System at the end of the procedureRate of positive user feedback on device placement trans-vaginally
Time to Visible Reduction in Blood FlowWhen removing the Alma System at the end of the procedureTime from insertion and start of negative pressure to visible reduction in blood flow
User Feedback on Connection to VacuumWhen removing the Alma System at the end of the procedureRate of positive user feedback on connection to vacuum and maintenance of desired negative pressure
Rate of Uterine ContractionWhen removing the Alma System at the end of the procedureRate of uterine contraction to a level that reduces or stops blood flow

Countries

Kenya

Contacts

Primary ContactOmondi Ogutu, Prof. M.D.
oomogutu@gmail.com254-722-510215
Backup ContactAlfred Osoti, Prof. M.D.
alfredos@uonbi.ac.ke254-733-886664

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026