Does Diaphragm Electrical Activity Monitoring Predict Extubation Success in Children?

The Potential of Diaphragm Electrical Activity Monitoring to Predict Extubation Success in Children Requiring Mechanical Ventilation Support Due to Respiratory Failure

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06163183
Enrollment
25
Registered
2023-12-08
Start date
2014-08-01
Completion date
2015-07-30
Last updated
2023-12-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diaphragm Electrical Activity, Neurally Adjusted Ventilatory Assist, Pediatrics

Keywords

pediatrics, extubation success, Diaphragm electrical activity

Brief summary

This study aimed to record diaphragm electrical activity (Edi) during the preextubation (weaning) and postextubation periods and to analyze whether Edi monitoring could predict extubation success.

Detailed description

This prospective observational study included 25 pediatric patients who were intubated due to respiratory failure in the pediatric intensive care unit of the tertiary university-affiliated Marmara University Hospital between August 2014 and July 2015. To conduct the study, we obtained informed consent from the patient's parents and ethical approval from the Marmara University Faculty of Medicine Scientific Research Ethics Committee Board on 06.09.2014. Pediatric patients included which had indication for the insertion of a nasogastric tube (Edi catheter), independent of the study. So Edi catheter had been used instead of nasogastric tube. When the patients were ready for clinical weaning in accordance with the clinician, the Edi catheter was appropriately inserted into the patients. Then, a spontaneous breathing trial (SBT) was performed and diaphragm activity monitoring was recorded during this process. The patients who met the inclusion criteria switched in a spontaneous breath trial with pressure support ventilation (PSV) or NAVA (Neurally Adjusted Ventilatory Assist) on a Maquet (Solna, Sweden) Servo-i mechanical ventilator for both ventilation modes The patients' demographic and clinical characteristics, mortality scoring, vital parameters (HR, TA, SpO2, RR) and ventilatory parameters (Edi peak, Edi min, FiO2, expiratory Vt), as well as follow-up period were recorded. Arterial/capillary blood gases were taken within the last four hours before extubation and within the first, sixth, 12th, 18th and 24th hours after extubation. If arterial blood gas monitoring was initiated in the patient, arterial monitoring was continued. If capillary blood gas monitoring was initiated, capillary monitoring was continued. Edi data were recorded for at least 24 hours before and after extubation. Edi values were obtained retrospectively from the trend diagram, which provides 24-hour continuous records on the ventilator screen.

Interventions

DEVICEEdi catheter

Sponsors

Mersin University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
2 Months to 17 Years
Healthy volunteers
No

Inclusion criteria

* • Aged between one month and 18 years old * Intubated for more than 48 hours due to respiratory failure * Indication for the insertion of a nasogastric tube (Edi catheter), independent of the study * Ready for weaning: * Normal vital signs for age (fever, heart rate (HR), respiratory rate (RR), tension arterial (TA) * No catecholamines or sedation drugs * pH of 7.35 to 7.45 * Positive end expiratory pressure (PEEP) ≤6 mmHg * Fractionated oxygen (FiO2) ≤0.5 * Oxygen saturation (SpO2) ≥92% * Vt≥ 5 ml/kg

Exclusion criteria

* • Contraindication for the insertion of the nasogastric tube (Edi catheter) * Patients treated with muscle relaxants * Absence of consent given by the patient's family * Cases whose Edi levels could not be taken from ventilator's trend diagram due to missing values.

Design outcomes

Primary

MeasureTime frameDescription
Diaphragm electrical activity (Edi) monitoringup to 2 daysMacquet (servo-i) mechanical ventilator measures the electrical activity (Edi) of the diaphragm (microvolts). Edi signals are measured using special feeding tubes (Edi catheter) equipped with tiny sensors at the level of gastroesophageal junction. In the ventilator, Edi trend values can be monitored continuously as 24-hour records.
Mechanical ventilatory monitoringup to 2 daysventilatory parameters (Edi peak, Edi min, FiO2), were recorded during the follow up.

Secondary

MeasureTime frameDescription
Arterial/capillary blood gasesArterial/capillary blood gases were taken within the last four hours before extubation and within the first, sixth, 12th, 18th and 24th hours after extubation.If arterial blood gas monitoring was initiated in the patient, arterial monitoring was continued. If capillary blood gas monitoring was initiated, capillary monitoring was continued.
Vital signs ((fever, heart rate (HR), respiratory rate (RR), tension arterial))up to 2 daysVital signs recorded by pediatric intensive care nurses.
Expiratory tidal volumeFrom spontaneous breathing trial until the time for extubationPatients who had \>5ml/kg expiratory tidal volume considered to be ready for extubation