Skip to content

The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement

The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06162195
Acronym
ACTIVE
Enrollment
200
Registered
2023-12-08
Start date
2026-07-21
Completion date
2036-12-31
Last updated
2026-08-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Inflammatory Arthritis, Osteoarthritis, Hip

Keywords

Hip, Resurfacing, Ceramic

Brief summary

The goal of this randomised controlled trial is to compare the success of two types of hip replacement in patients with hip arthritis. The main question it aims to answer is whether a new type of hip replacement (called a hip resurfacing) can be as successful as an existing hip replacement (called a total hip replacement). Patients will be given either the new hip resurfacing or the existing total hip replacement and researchers will compare their function, complication rate and physical activity.

Detailed description

The H1 Implant is a cementless, ceramic hip resurfacing arthroplasty (HRA) device. The intended purpose of the H1 Implant is to provide an artificial substitute for a disease-damaged hip joint to replace the articulating surfaces of the hip while preserving the underlying femoral head and natural femoral neck. This is standard for a resurfacing hip prosthesis. This study will randomise patients to receive either The H1 Implant or a primary cementless ceramic-on-poly or ceramic-on-ceramic total hip replacement (THR). Composite clinical success (CCS) scores, physical activity levels and patient reported outcome measures (PROMs) will be compared for the two groups. The primary objective of the study is to determine whether the H1 Implant is non-inferior to cementless THR in terms of CCS. The key secondary objective is to determine whether the H1 Implant is superior compared to cementless THR in terms of physical activity and PROMs. Other secondary objectives are to compare the H1 Implant and THR with respect to: safety, through collection of all device-related, operative site-related and systemic adverse events; and noise generation, through patient survey.

Interventions

DEVICEThe H1 Implant

Patients allocated to The H1 Implant arm will be implanted with the H1 Implant which is a cementless, ceramic hip resurfacing device.

DEVICECementless total hip replacement

Patients allocated to cementless total hip replacement arm will be implanted with a cementless ceramic-on-poly or ceramic-on-ceramic total hip replacement

Sponsors

Embody Orthopaedic Limited
Lead SponsorINDUSTRY
Imperial College London
CollaboratorOTHER
National Institute for Health Research, United Kingdom
CollaboratorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Masking description

The patients, clinical assessors and data analysts will be blinded to the intervention each patient has received for the 24 month post-operative period. The surgeon, operating theatre team, radiographic analysts and CRO cannot be blinded but will not be involved in the care of the patient after the intervention unless the patient requires revision surgery.

Intervention model description

Randomisation will be performed using variable block randomisation with block sizes of 4, 6 and 8, with a 1:1 allocation to the 2 groups, with stratification across sites. This will ensure approximately equal numbers across groups and approximately the same number per group at each site (to control for differences in the trial population because of environmental, social and demographic factors), while allowing different total numbers at each site. It will also ensure that at any given time, the numbers in each group will be approximately equal, allowing the interim analyses to take place. The randomisation will be managed by the contract research organisation (CRO) via an electronic data capture (EDC) system, which uses a validated randomisation algorithm. Once a patient has been consented, they will be assigned to a treatment group according to the pre-determined order inside the block. Stratification by site is recommended for multi-centre studies.

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patient requires unilateral primary hip arthroplasty due to primary osteoarthritis, osteoarthritis secondary to e.g. trauma, avascular necrosis or developmental hip dysplasia, or inflammatory arthritis. * Patient is willing to comply with study requirements. * Patient plans to be available through 10 years postoperative follow-up.

Exclusion criteria

* Patient has a BMI greater than 40 kg/m². * Patient has active infection or sepsis (treated or untreated). * Patient has insufficient bone stock at the hip (\>1/3 necrosis of the femoral head or large and multiple cysts) or in general as in severe osteopenia or osteoporosis (t-score \< -2.5 as measured with BMD). * Patient is not skeletally mature. * Patient meets the contraindication criteria of the control device. * Patient already has another lower limb arthroplasty or arthrodesis or will require a further lower limb arthroplasty or arthrodesis within the subsequent 2 years. * Patient lacks capacity to consent. * Patient is unable to understand the native language of the country where their procedure is taking place

Design outcomes

Primary

MeasureTime frameDescription
Composite clinical success (CCS)24 months post-operativelyThe primary outcome is "composite clinical success". This is a binary outcome measure. Patients are deemed to have achieved CCS if they meet all of the following criteria at the 24 month timepoint: * Modified Harris Hip Score ≥80. * No revision or pending revision. * Acetabular radiolucencies: not in all zones. * Femoral radiolucencies: not in all zones. * Absence of subsidence/migration of the acetabular or femoral component \>5mm with clinical findings. * Absence of specific adverse device effects (ADEs) that are pre-cursors to revision of the device, namely: * Bone breakage around the implanted component(s) (periprosthetic fracture). * Breakage of the device component. * Device movement/migration of clinical consequence as defined by associated clinical findings as: a limp; leg length discrepancy; and restricted range of motion. * Dislocation of the hip joint.

Secondary

MeasureTime frameDescription
Physical Activity6 months, 12 months and 24 months post-operativelyAverage daily minutes of activity and mean bouted daily moderate-vigorous physical activity (MVPA), minutes
Noise6 weeks, 6 months, 12 months and 24 months post-operativelyNoise questionnaire

Countries

United Kingdom

Contacts

CONTACTCamilla Halewood, PhD
camilla.halewood@embody-ortho.com+442035764981
CONTACTSusannah Clarke, PhD
susannah.clarke@embody-ortho.com+442035764981
PRINCIPAL_INVESTIGATORJustin Cobb, Prof

Imperial College London

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 14, 2026