Skip to content

To Evaluate the Safety and Effectiveness of Flow Modulation Device for Intracranial Aneurysms

A Prospective, Multicenter, Single Arm Clinical Trial to Evaluate the Safety and Effectiveness of Flow Modulation Device for Intracranial Aneurysms

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06158750
Enrollment
120
Registered
2023-12-06
Start date
2023-11-17
Completion date
2026-06-30
Last updated
2024-06-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm

Brief summary

The purpose of this study is to assess safety and effectiveness of the p64/p48 MW HPC Flow Modulation Device.

Detailed description

Title: A prospective, multicenter, single arm clinical trial to evaluate the safety and effectiveness of Flow Modulation Device for intracranial aneurysms. Device: p64/p48 MW HPC Flow Modulation Device. Study design: Prospective, multicenter, single arm Clinical Study. Purpose: To assess safety and effectiveness of p64/p48 MW HPC Flow Modulation Device . Study duration: 32 months. Sample Size: 120 patients. Number of sites: ≤10. Follow-up time: 12 months.

Interventions

DEVICEp64/p48 MW HPC Flow Modulation Device

Endovascular intervention with p64/p48 MW HPC Flow Modulation Device was performed in patients diagnosed with intracranial aneurysms

Sponsors

Phenox GmbH
CollaboratorINDUSTRY
Beijing Wallaby Medical Technologies Co.,Inc.
CollaboratorUNKNOWN
Shanghai Wallaby Medical Technologies Co.,Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Aged from 18 to 80 years, male or female; * Patients diagnosed as intracranial aneurysms by brain CTA/MRA/DSA; * Patients with unruptured saccular aneurysms or fusiform aneurysm who are clinically determined to use flow modulation device for endovascular treatment; * The diameter of the target aneurysm parent vessel was 1.75-5mm; * Patients target aneurysm is planned to be embolized using flow modulation devices only; * The mRS Score of the patients was 0-2 * Patients understand the purpose of the study, accept the follow-up period, and agree to comply with all requirements, agree to participate in the clinical trial and voluntarily sign the informed consent.

Exclusion criteria

* Patients who have contraindications to antiplatelet and/or anticoagulant therapy or do not start antiplatelet therapy in time before treatment; * Patients with anatomical structure is not suitable for endovascular treatment due to severe vascular tortuosity or stenosis shown by angiography; * Patients with acute ruptured aneurysm or with a history of intracranial hemorrhage or subarachnoid hemorrhage within 30 days before surgery; * Patients with target aneurysm treated with endovascular interventional therapy before enrollment; * Known to be allergic to Nitinol platinum alloy and angiographic agents; * Conditions that in the opinion of the investigators would prevent patients from completing the study, such as the expected survival period of active tumor less than 1-year, high-risk group of cerebral thrombosis, heart failure and atrial fibrillation; * The target aneurysms were blood vesicular aneurysms, pseudoaneurysms, or aneurysms associated with arteriovenous malformation, moyamoya disease, or multiple aneurysms that could not be treated by a single flow modulation device; * Serious infection is not controlled and is not suitable for operation; * Patients who underwent major surgery or interventional therapy (such as brain, cardiac, chest, abdominal or peripheral vascular) within 30 days before surgery; * Obvious abnormal coagulation function or bleeding tendency; * Combined with severe renal insufficiency, creatinine greater than or equal to 200umol/L; Patients with severe liver diseases (such as acute and chronic hepatitis, cirrhosis), or ALT more than 3 times the upper normal limit; * Pregnancy, lactation, or women of childbearing age who plan to be pregnant during the study period; * Participation in any other clinical trial within 30 days prior to signing informed consent; * Other conditions considered by the investigator to be inappropriate for enrollment.

Design outcomes

Primary

MeasureTime frameDescription
Rate of complete occlusion12 monthsRaymond grade was evaluated by the independent imaging evaluation Committee 12 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated. Aneurysm complete occlusion is defined as Raymond Grade I.

Secondary

MeasureTime frameDescription
Rate of successful occlusion6 months, 12 monthsRaymond grade was evaluated by the independent imaging evaluation Committee 6 months and 12 months after surgery according to the subjects' imaging results, and the rate of successful aneurysm occlusion was calculated. Aneurysm successful occlusion is defined as Raymond Grade I/II.
Rate of complete occlusion6 monthsRaymond grade was evaluated by the independent imaging evaluation Committee 6 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated. Aneurysm complete occlusion is defined as Raymond Grade I.
Rate of good clinical prognosis3 months, 6 months, 12 monthsGood clinical prognosis means mRS 0\ 2
Technical success rateWithin 24 hours after surgeryTechnical success is defined as the successful placement of a Flow Modulation Device. Successful implantation means that the Flow Modulation Device is placed at the target site and effectively covers the neck of the aneurysm, and the rest of the device is successfully released and withdrawn to the outside of the body.
Device performance evaluationWithin 24 hours after surgeryAfter each use of the device, the researchers evaluated the operational performance of the device in terms of conveying, flexibility, compliance and wall adhesion.
Death, stroke, and thrombotic eventsto 12 monthsRecord the number of death, stroke and thrombotic events throughout the clinical trial period.
Rate of in-stent-stenosisto 6 months, to 12 monthsIn-stent-stenosis defined as moderate or severe stenosis of the tumor artery, that is, stenosis \> 50%

Countries

China

Contacts

Primary ContactWenwen Jia
Wendy.Jia@wallabyphenox.com+86 18818201005

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026