Skip to content

An Exploratory Study of Focal Pulse Ablation System in the Treatment of Atrial Arrhythmia

An Exploratory Study of Focal Pulse Ablation System in the Treatment of Atrial Arrhythmia

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06157437
Enrollment
10
Registered
2023-12-05
Start date
2023-12-01
Completion date
2025-06-30
Last updated
2025-02-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation (AF), Typical Atrial Flutter

Brief summary

This is a prospective, single-group clinical study. The objective is to evaluate the safety and efficacy of focal pulse ablation system in the treatment of typical atrial flutter.

Interventions

DEVICEFocal Pulse field Ablation

Bidirectional block of the cavo-tricuspid isthmus (CTI) was performed with the novel focal pulse field ablation.

Sponsors

Hangzhou Dinova EP Technology Co., Ltd
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Subjects aged at least 18; * Subjects with at least one typical atrial flutter attack recorded by ECG or holter in the 180 days prior to enrollment, and the ECG of other hospitals could be accepted; * Subjects are able to understand the purpose of the study, voluntarily participate in the study and sign the informed consent, and are willing to complete the follow-up according to the requirements of the program.

Exclusion criteria

* Any prior cavo-tricuspid isthmus ablation; * Unstable angina; * Atrial flutter secondary to electrolyte disorder, thyroid disease or other reversible causes; * Myocardial infarction or coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) within the prior three months; * At baseline, New York College of Cardiology (NYHA) heart function grades III and IV; * Implantable devices such as ICDs, CRTS and pacemakers in the body; * Atrial or ventricular tumors, blood clots, thrombus, or known clotting disorders were recorded within the prior 90 days; * Severe structural heart disease, including tricuspid stenosis, tricuspid malformation, or other congenital heart disease that prevents ablation surgery; * Previously received tricuspid metal valve replacement; * Thromboembolic events (including transient ischemic attacks) within the past 6 months; * Mural thrombosis, tumor, or other abnormality that interferes with vascular puncture or catheter operation; * Severe lung disease, pulmonary hypertension or any lung disease involving abnormal blood gas or severe breathing difficulties; * Anticoagulation contraindications and a history of blood clotting or abnormal bleeding; * Acute systemic infection; * Serum creatinine greater than twice the upper limit of normal, or any history of renal dialysis; * Women who are pregnant or breastfeeding or who cannot use contraception during the study period; * Enrollment in another clinical trial evaluating other devices or drugs during the same period; * Life expectancy less than 12 months (e.g. advanced malignancy); * Abnormalities or diseases considered by the investigator to be excluded from inclusion in this study.

Design outcomes

Primary

MeasureTime frameDescription
Acute procedural successimmediately after the procedureAcute procedural success is defined as the creation of bidirectional conduction block across the cavo-tricuspid isthmus immediately and 30 minutes after ablation.

Secondary

MeasureTime frameDescription
Chronic success6 months after procedureChronic success is defined as the absence of recurrent atrial flutter at 6 months post-ablation according to electrocardiogram data, including electrocardiogram, 24-hour Holter.
Ablation efficiency including total procedure time, catheter dwell time, pulse discharge time and total X-ray exposure timeimmediately after the procedureTotal procedure time (defined as the total time from initial femoral venipuncture to final catheter removal), catheter dwell time (time between the pulsed field ablation catheter entering the left atrium and its withdrawal from the left atrium), pulse discharge time (The total time of delivering pulse energy through the pulsed field ablation catheter, single ablation time ablation times), total X-ray exposure time (the total time of X-ray imaging of the catheter)
Incidence of device-related major adverse events (MAE) within 7 days after ablationwithin 7 days after ablationDevice-related MAE includes death, myocardial infarction, pulmonary embolism, stroke /TIA, severe pericardial effusion, and complete atrioventricular block.
Incidence of device-related severe adverse events (SAE)3 months and 6 months after procedureDevice-related SAE refers to a device-related event that occurs during the clinical trial that results in mortality or serious deterioration in patient health, including a fatal illness or injury, a permanent defect in body structure or body function, or an event that requires medical or surgical intervention to avoid one or more permanent defects in body structure or body function.

Countries

China

Contacts

Primary ContactHaitao Yang
dinova_ep@dnaeps.com+8637158680341

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026