Skip to content

Performance of Robotic Microsurgery Systems

Preclinical Performance of The Combined Application of Two Robotic Systems in Microsurgery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06146023
Enrollment
18
Registered
2023-11-24
Start date
2022-10-01
Completion date
2023-07-01
Last updated
2023-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anastomosis, Microsurgery, Robotic Surgery

Keywords

Learning curve, Robotics, Surgical ergonomics, Surgical training

Brief summary

The goal of this preclinical trial is to learn about the benefits and limitations of novel robotic devices for microsurgery, based on different levels of microsurgical experience. The main questions it aims to answer are: Is robot-assisted microsurgery faster, better and more ergonomic than conventional microsurgery in a preclinical standardized setting? Participants will perform microvascular anastomoses on 1.0-mm-diameter artificial silicone vessels using a conventional manual approach versus a novel robot-assisted approach. Researchers will compare the performance of novices, advanced participants and experts to evaluate the role of microsurgical experience when learning the new technique.

Detailed description

Recent advancements in the development of robotic devices increasingly draw the attention towards the concept of robotic microsurgery, as several systems tailored to open microsurgery are being introduced. This study describes the combined application of a novel microsurgical robot, the Symani, with a novel robotic microscope, the RoboticScope, for the performance of microvascular anastomoses in a two-center preclinical trial.

Interventions

PROCEDUREConventional anastomosis

Conventional microvascular anastomosis on 1.0-mm-diameter silicone vessels using conventional microsurgical instruments and conventional surgical microscope

DEVICERobotic anastomosis (Symani surgical system and RoboticScope)

Robot-assisted microvascular anastomosis on 1.0-mm-diameter silicone vessels using the Symani surgical system and RoboticScope

Sponsors

Yale University
CollaboratorOTHER
University Hospital Muenster
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Masking description

Outcome assessors are blinded for participant groups and number of anastomosis during evaluation of scores.

Intervention model description

Comparison of conventional manual microsurgery versus robot-assisted microsurgery

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* Novices: no prior experience in microsurgery * Residents: 2-4 years of experience in microsurgery * Experts: at least 5 years of experience in microsurgery

Exclusion criteria

* previous training with the robotic devices applied in this study * contraindications for usage of robotic devices (magnetic field)

Design outcomes

Primary

MeasureTime frameDescription
Surgical timeDuration of anastomosisTime to perform anastomosis in minutes and seconds.
Anastomosis qualityEvaluated right after completion of each anastomosisAnastomosis lapse index (ALI) to evaluate the quality of each stitch. Score indicates absolute number of errors per anastomosis. Low values indicate better results.
Microsurgical skillsDuration of anastomosisStructured assessment of microsurgery skills (SAMS) to evaluate microsurgical skill acquisition. Score includes 8 items evaluated from 1 (minimum) to 5 (maximum). High values indicate better results.

Secondary

MeasureTime frameDescription
Subjective SatisfactionEvaluated right after completion of each anastomosisSatisfaction with anastomosis und robotic performance (Questionnaire). Evaluation of anastomosis and robotic devices from 1 (minimum) to 10 (maximum). High values indicate better results.
Surgical ergonomicsEvaluated right after completion of each anastomosisRapid entire body assessment (REBA) to evaluate surgical ergonomics. Numeric score, low values indicate better results.

Countries

Germany, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026