Skip to content

Comparison of Upper and Lower Limb Maximal Exercise Capacities and Muscle Oxygenation in Patients With ILD

Comparison of Upper and Lower Limb Maximal Exercise Capacities, Muscle Oxygenation and Energy Consumption During Tests in Patients With Interstitial Lung Disease

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06141603
Enrollment
30
Registered
2023-11-21
Start date
2023-11-25
Completion date
2024-12-30
Last updated
2023-12-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Interstitial Lung Disease

Keywords

interstitial lung disease, muscle oxygenation, cardiopulmonary exercise testing

Brief summary

Interstitial lung diseases (ILD) are a complex group of diseases that cause significant morbidity and mortality, develop diffuse lung parenchyma and alveolar inflammation, as well as interstitial fibrosis, which refers to more than 200 diseases. Due to restrictive type ventilation disorder and impaired pulmonary gas exchange, pulmonary function has deteriorated in these patients and progressive shortness of breath, fatigue, cough and exercise intolerance are usually observed, which also affects the quality of life.

Detailed description

As a result of the chronic inflammatory process of the disease, structural and mechanical pulmonary disorders develop, which are cited as the causes of deterioration in cardiopulmonary functions. In these patients, there is a decrease in static and dynamic lung volumes and carbon monoxide diffusion capacity. As a result of this mechanism, the level of physical activity decreases due to increased shortness of breath during activity. In ILD, there is a decrease in peripheral November muscle strength of both the upper extremities and lower extremities. November it was stated that the weakness of the skeletal muscles of the lower extremities was more pronounced than the skeletal muscles of the upper extremities due to disuse in these patients, and the muscle strength of the upper extremities did not decrease significantly. However, it has been reported that upper limb exercise capacity is worse than lower limb exercise capacity. Arterial hypoxemia is shown as the main reason for the decrease in exercise performance, and peak oxygen consumption (VO2peak) decreased in these patients. In healthy people, respiratory frequency, tidal volume (VT), minute ventilation and oxygen consumption increase during exercise. In interstitial lung patients, vital capacity decreases at rest, which leads to limitation of VT. Lung compliance decreases and respiratory workload increases. The respiratory workload, which increases even more during exercise, has a bad effect on ventricular function. This causes a lower oxygen pulse and pulse volume in patients during exercise than in healthy individuals. The primary aim of the study: To compare the maximal exercise capacities and muscle oxygenation during cardiopulmonary exercise tests of upper and lower extremities in patients with interstitial lung disease. The secondary aim of the study is to compare energy consumption and the perception of dyspnea and fatigue during tests in patients with interstitial lung disease. The primary outcome will be upper and lower maximal exercise capacities (cardiopulmonary exercise tests) and muscle oxygenation during cardiopulmonary exercise tests (Near-infrared spectroscopy) device). Secondary outcome will be energy consumption (multi sensor activity device), the perception of dyspnea (Modified Borg Scale (MBS)) and fatigue (MBS).

Interventions

None listed

Sponsors

Gazi University
Lead SponsorOTHER

Study design

Observational model
CASE_CROSSOVER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* patients between the ages of 18-75 with interstitial lung disease

Exclusion criteria

* acute infection during the study * have an orthopedic or neurological disease that will affect their exercise capacity * acute exacerbation or any infection * have contraindications to the exercise test * an acute respiratory infection * had Coronavirus-19 (COVID-19) disease in the last 3 months * have undergone different treatments other than standard medical treatment

Design outcomes

Primary

MeasureTime frameDescription
Peripheral Muscle Oxygenationthrough study completion, an average of 1 yearPeripheral muscle oxygen will be measured by near-infrared spectrometry. The device probes will be placed on the upper and lower extremities for both tests. The device allows to display of the percentage of oxygen, the concentration of oxyhemoglobin, and deoxyhemoglobin, the difference between oxyhemoglobin and deoxyhemoglobin, and the total hemoglobin. These parameters will be evaluated in our study.

Secondary

MeasureTime frameDescription
Energy Consumption During Teststhrough study completion, an average of 1 yearEnergy consumption will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient wear the multi sensor physical activity monitor over the triceps muscle of the non-dominant arm during CPETs. Energy consumption (joule / day) will be measured with the multi-sensor physical activity monitor. The measured parameter will be averaged and analyzed with the SenseWear® 7.0 Software program.
Physical Activity Level (Total energy expenditure)through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Total energy expenditure (joule / day) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Physical activity (Active energy expenditure (joule / day))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Active energy expenditure (joule / day) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Physical activity (Physical activity time (min / day))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Physical activity time (min / day)will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Physical activity (Average metabolic equivalent (MET / day))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Average metabolic equivalent (MET / day) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Maximal Exercise Capacitythrough study completion, an average of 1 yearMaximal Exercise capacity will be evaluated with Cardiopulmonary Exercise testing. The Cardiopulmonary Exercise Testing will be applied according to American Thoracic Society (ATS) and European Respiratory Society (ERS) criteria.
Physical activity (Time spent lying down (min / day) days))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Time spent lying down (min / day) days) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Physical activity (Sleep time (min / day))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Sleep time (min / day) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.
Peripheral Muscle Strengththrough study completion, an average of 1 yearIsometric peripheral muscle strength will be measured with a portable hand dynamometer (JTECH Commander, USA). Measurements will be repeated on the shoulder abductors and knee extensors three times on the right and left.
Dyspneathrough study completion, an average of 1 yearModified Borg Scale: The Modified Borg scale is a subjective scale that scores 0-10 for breathlessness and fatigue at rest and/or during activity. The lowest 0 points not at all the highest 10 points very severe means shortness of breath.
Fatiguethrough study completion, an average of 1 yearFatigue will be measured by the Turkish adaptation of the Fatigue Severity Scale. The Fatigue Severity Scale (FSS) is a scale that evaluates fatigue and consists of 9 questions. Scores can be taken from the scale in the range of 0 to 63 points. Each item is scored between 0 and 7 points. The total score is divided by 9 and if the average is less than 4, there is no fatigue, and if more than 4 points, it is considered that there is fatigue.
Physical activity (Number of steps (steps / day))through study completion, an average of 1 yearPhysical activity will be evaluated with the Multi sensor activity monitor (SenseWear®, Inc Pittsburgh, ABD). The patient will wear the multisensor physical activity monitor over the triceps muscle of the non-dominant arm for 4 continuous days. The patient will be informed about removing the device while taking a bath. Number of steps (steps / day) will be measured with the multi-sensor physical activity monitor. The parameters measured over two days will be averaged and analyzed with the SenseWear® 7.0 Software program.

Countries

Turkey (Türkiye)

Contacts

Primary ContactMeral BOŞNAK GÜÇLÜ, Prof. Dr.
meralbosnak@gazi.edu.tr03122162647
Backup ContactBeyza Nur ÖYMEZ, Pt.
beyzanuroymez@gmail.com

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026