Skip to content

Spectacle Films Utilising S.T.O.P.® Technology for Slowing Down Myopia Progression in Children

Spectacle Films Utilising S.T.O.P.® Technology for Slowing Down Myopia Progression in Children: A Prospective, Masked, Controlled, Randomised, Clinical Trial.

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06137560
Enrollment
210
Registered
2023-11-18
Start date
2023-12-22
Completion date
2028-03-01
Last updated
2026-06-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopia

Brief summary

There are two parts to this trial. First, to compare the rate of myopia progression of spectacle films using Spatio Temporal Optic Phase (S.T.O.P.®) technology that provide a dynamic optical cue against single vision spectacle lenses. Second, to compare the rate of myopia progression of spectacle films using S.T.O.P.® technology that provide a dynamic optical cue against spectacle films using S.T.O.P.® technology that provide a static optical cue. A dynamic optical cue is one that changes, and a static optical cue is one that does not change.

Detailed description

In the first part of the trial, myopic children (6-14 years of age) will be randomly allocated to wear one of three spectacle lens options (standard single vision spectacle lenses, standard single vision spectacle lenses + S.T.O.P.® Kit 1 spectacle films, or standard single vision spectacle lenses + S.T.O.P.® Kit 2 spectacle films). S.T.O.P.® spectacle films are applied to the front surface of standard single vision spectacle lenses. Both S.T.O.P.® Kits 1 and 2 are comprised of two different sets of spectacle films applied to two different pairs of single vision spectacle lenses which are worn on alternate weeks, and thus both S.T.O.P.® Kits 1 and 2 provide a dynamic optical cue. In the second part of this trial, participants will be randomly allocated wear of of two spectacle lens options (the best performer from S.T.O.P.® Kits 1 and 2 in terms of reducing the rate of myopic progression and single vision spectacle lenses + S.T.O.P.® film). As previously stated, both S.T.O.P.® Kits 1 and 2 provide a dynamic optical cue while S.T.O.P.® film provide a static optical cue. The overall trial duration, including follow-up period, is expected to be approximately 42 months. Each participant's duration is expected to be approximately 30 months. The visits are Baseline, Dispensing, 1 month, 4 months, 6 months, then visits every 6 months after. All procedures performed at these visits are standard, non invasive clinical tests.

Interventions

Standard single vision spectacle lens

DEVICESingle vision spectacle lens + S.T.O.P.® Kit 1

Standard single vision spectacle lens + S.T.O.P.® Kit 1

DEVICESingle vision spectacle lens + S.T.O.P.® Kit 2

Standard single vision spectacle lens + S.T.O.P.® Kit 2

DEVICESingle vision spectacle lens + S.T.O.P.® Film

Standard single vision spectacle lens + S.T.O.P.® Film

DEVICEStandard single vision spectacle lens + S.T.O.P.® Kit 1 or 2

Standard single vision spectacle lens + S.T.O.P.® Kit 1 or 2

Sponsors

nthalmic Pty Ltd
Lead SponsorNETWORK
Zhong Jing Wei Shi (Suzhou) Optical Technology Ltd.
CollaboratorUNKNOWN

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Subject, Caregiver)

Eligibility

Sex/Gender
ALL
Age
6 Years to 14 Years
Healthy volunteers
No

Inclusion criteria

* Be between 6-14 years inclusive at time of enrolment. * Have: * Read the Informed Assent. * Been explained the Informed Assent. * Indicated an understanding of the Informed Assent. * Signed the Informed Assent. * Have their parent / legal guardian: * Read the Informed Consent. * Been explained the Informed Consent. * Indicated an understanding of the Informed Consent. * Signed the Informed Consent. * Along with their parent / legal guardian, be capable of comprehending the nature of the study, and be willing and able to adhere to study requirements. * Along with their parent / legal guardian, agree to maintain the visit and prescribed wearing schedule. * Agree to wear allocated spectacles for a minimum of 5 days per week, at least 6 hours per day for the duration of the study and to inform the investigator if their schedule is interrupted. * Possess wearable and visually functioning spectacles. * Be in good general health, based on the parent's / legal guardian's knowledge. * Have best-corrected high contrast visual acuity based on manifest refraction of 0.10 logMAR (20/25, 6/7.6) or better in each eye. * Meet the following criteria determined by cycloplegic autorefraction at Baseline: * -5.00 D ≤ spherical equivalent ≤ -0.75 D and sphere component ≤ -0.50 DS. * -1.50 DC ≤ astigmatic component ≤ 0 DC. * \|Spherical equivalent anisometropia\| ≤ 1.00 D.

Exclusion criteria

* Participant is currently, or within 30 days prior to this study, has been an active participant in another study. * Current or prior use of ANY form of myopia control, including but not limited to: * Optical devices: * Bifocal or multifocal spectacles of any type. * Bifocal or multifocal contact lenses of any type. * Orthokeratology of any type. * Pharmacological agents: * Atropine with a concentration \> 0.01%. Participants who have previously used 0.01% atropine are eligible for this study provided they agree not to use 0.01% atropine for at least 30 days before baseline and at any time during the study. * Pirenzepine * Participant born earlier than 30 weeks or weighed \< 1500 g at birth. * A verbal report from the participant's parent / legal guardian is sufficient. * Habitual use of a systemic or topical medication that may alter normal ocular findings / is known to affect a participant's ocular health / physiology either in an adverse or beneficial manner at enrolment and / or during the clinical trial. * A known allergy to sodium fluorescein, benoxinate, proparacaine, tropicamide, or cyclopentolate. * Strabismus as determined by cover test at distance (≥ 3 m) or near (40 cm) while wearing distance correction under non-cycloplegic conditions. * Known ocular or systemic disease, such as but not limited to: * Diabetes. * Graves' disease. * Glaucoma. * Uveitis. * Scleritis. * Auto immune diseases such as ankylosing spondylitis, multiple sclerosis, Sjogrens syndrome, and systemic lupus erythematosus. * Any ocular, systemic, or neuro-developmental conditions that could influence refractive development, such as but not limited to: * Persistent pupillary membrane. * Vitreous haemorrhage. * Cataract. * Central corneal scarring. * Eyelid haemangiomas. * Marfan's syndrome. * Down's syndrome. * Ehler's-Danlos syndrome. * Stickler's syndrome. * Ocular albinism. * Retinopathy of prematurity. * Keratoconus or irregular cornea. * The investigator may, at their discretion, exclude anyone who they believe may not be able to fulfil the clinical trial requirements or it is believed to be in the participant's best interests.

Design outcomes

Primary

MeasureTime frameDescription
Axial lengthBaseline, First Dispense (up to 26 days from Baseline), then 1 month, 4 months, and 6 months after First DispenseDifference in change from Baseline in axial length between single vision (control) and S.T.O.P.® Kit 1 \& 2 (tests)

Secondary

MeasureTime frameDescription
Cycloplegic spherical equivalent autorefractionBaseline, First Dispense (up to 26 days from Baseline), then 1 month, 4 months, and 6 months after First DispenseDifference in change from Baseline in cycloplegic spherical equivalent autorefraction between single vision (control) and S.T.O.P.® Kit 1 \& 2 (tests)
Visual performance as measured by high contrast visual acuity at 6 m1 month, 4 months, and 6 months after First Dispense (up to 26 days from Baseline)Difference in visual performance between single vision (control) and S.T.O.P.® Kit 1 \& 2 (tests)
Visual performance as measured by a non validated questionnaire based on a 1-101 month, 4 months, and 6 months after First Dispense (up to 26 days from Baseline)Difference in visual performance between single vision (control) and S.T.O.P.® Kit 1 \& 2 (tests)

Countries

China, India

Contacts

PRINCIPAL_INVESTIGATORDaniel Tilia, Optom, PhD

nthalmic Pty Ltd

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 18, 2026