Skip to content

Reliability of Force Measurement Within the Carbon Fiber Orthosis Proximal Cuff

Reliability of Force Measurement Within the Carbon Fiber Orthosis Proximal Cuff

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06127264
Acronym
CuffForce
Enrollment
60
Registered
2023-11-13
Start date
2024-03-01
Completion date
2026-12-31
Last updated
2025-12-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ankle Foot Orthosis (AFO), Healthy, Peripheral Neuropathy

Keywords

Ankle Foot Orthosis, Carbon Fiber Orthosis, Plantar Force

Brief summary

The primary purpose of this research study is to determine if forces within carbon fiber custom dynamic orthoses (CDOs) can be reliability assessed using Loadpad and Loadsol force measuring sensors (Novel GMBH, St. Paul, MN). An improved understanding of the forces acting within orthoses may help to guide future orthosis related research studies, provision methods, and patient education. Study participants will consist of three groups; 1) healthy, able-bodied adult participants using generic sized CDOs, which consist of a proximal cuff that wraps around the leg just below the knee, a posterior carbon fiber strut that runs the length of the leg and bends to store and return energy, and a semi-rigid footplate that acts as a lever arm to bend the posterior strut, 2) individuals without peripheral neuropathy who use AFO(s) regularly, and 3) individuals with peripheral neuropathy who use AFO(s) regularly. . Group 1 participants will be asked to fasten the proximal cuff to a self-selected cuff tightness 'SSCT', as well as three different predefined force levels; 'Loose' where the proximal cuff is loosely fastened around the participants leg, 'Moderate' where the proximal cuff is fastened with moderate tightness, and 'Tight' where the proximal cuff is tightly fastened around the participants leg. Testing in the predetermined force levels (Loose, Moderate, Tight) will occur in a randomized order. Group 2 and Group 3 participants will be asked to fasten their AFO(s) to a self-selected 'SSCT' tightness. For all groups, forces acting on the leg, within the proximal cuff, will be measured using wireless Loadpad sensors and forces acting on the foot will be measured using wireless Loadsol insoles. Testing will include collection of force data as participants sit quietly, stand quietly, and walk and completion of questionnaires.

Detailed description

Ankle foot orthoses (AFOs) are medical devices often used to support the foot and ankle during daily activities. Carbon fiber custom dynamic orthoses (CDOs), one subset of AFOs, that consist of a proximal cuff that wraps around the leg just below the knee, a posterior carbon fiber strut that runs the length of the leg and bends to store and return energy during gait, a semi-rigid carbon fiber footplate that acts as a lever arm to bend the posterior strut, and in some cases a foam heel wedge placed between the footplate and the shoe. Different CDO design characteristics, such as posterior strut stiffness, device alignment, and heel cushion height and stiffness have been studied in the past. While different design characteristics have been studied previously, there is little information available concerning the proximal cuff and how it impacts patient outcomes. Different types of AFOs and CDOs have been used in an effort to offload the limb for years. Both CDOs and patellar tendon bearing (PTB) style AFOs have been shown to reduce forces acting on the plantar surface of the foot. While multiple studies have indicated the importance of fastening the proximal cuff, few have actually investigated the forces acting within the proximal cuff. A loose proximal cuff has been associated with pistoning of the limb, where the limb translates down within the proximal cuff during loading, potentially increasing forces acting on the foot and reducing the offloading effects of the orthosis. Only one study investigated the effects of altering forces within the proximal cuff by adding more padding to the proximal cuff, which was shown to improve limb offloading. A better understanding of the forces acting within the proximal cuff, and how these effect patient outcomes would help to guide future AFO related research studies, provision, and patient education. At this point in time there is little guidance available to inform patients how tightly they need to secure the proximal cuff when wearing an AFO, many clinicians recommend tightening it so that it's secure, but not uncomfortable. The ability to measure forces within the proximal cuff and an idea of the range of forces seen in a clinical setting will act as a first step to better understanding how forces acting within the proximal cuff impact patient outcomes.

Interventions

The carbon fiber custom dynamic orthosis (CDO) will consist of a semi-rigid carbon fiber footplate, a carbon fiber posterior strut, and a proximal cuff that wraps around the leg below the knee that is fastened to different tightness's

Sponsors

University of Iowa
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
SINGLE (Subject)

Masking description

Participants will be blinded, to the greatest extent possible, to the different CDO proximal cuff tightness's.

Intervention model description

Participants in Group 1 will be asked to fasten the proximal cuff to a self-selected cuff tightness 'SSCT', as well as three different predefined force levels; Loose, Moderate, and Tight. Participants in Group 2 and Group 3 will only be asked to fasten their AFO(s) to a self-selected tightness. Testing will occur without a CDO (NoCDO) and with each cuff tightness (SSCT, Loose, Moderate, Tight). Forces acting on the leg will be measured using wireless Loadpad sensors and forces acting on the plantar surface of the foot will be measured using wireless Loadsol insoles. Testing will include collection of force data as participants sit quietly, stand quietly, and walk and completion of questionnaires. Testing in the predetermined force levels (Loose, Moderate, Tight) will occur in a randomized order.

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
Yes

Inclusion criteria

Group 1 - Able Bodied Participants Inclusion Criteria * Between the ages of 18 and 65 * Healthy without current complaint of lower extremity pain, spine pain, open wounds or active infections, or medical or neuromusculoskeletal disorders that have limited their participation in work or exercise in the last 6 months * Able to hop without pain * Able to perform a full squat without pain * Ability to read and write in English and provide written informed consent * Ability to fit in a generic sized CDO

Exclusion criteria

* Diagnosed with a moderate or severe brain injury * Lower extremity injury resulting in surgery or limiting function for greater than 6 weeks * Injuries that would limit performance in this study * Diagnosed with a physical or psychological condition that would preclude functional testing (e.g. cardiac condition, clotting disorder, pulmonary condition) * Visual or hearing impairments that limit walking ability or limit the ability to comply with instructions given during testing * Require use of an assistive device * Unhealed wounds (cuts/abrasions) that would prevent AFO use * BMI \> 40 * Pregnancy Group 2 - AFO Users without Peripheral Neuropathy Inclusion Criteria: * Between the ages of 18 and 90 * Use an AFO(s) for daily activities * The AFO(s) proximal cuff is compatible with loadpad sensors * Have used their AFO(s) for a minimum of 2 weeks * Ability to walk 50 feet without use of an assistive device (e.g. cane, crutch, etc.) * Ability to read and write in English and provide written informed consent

Design outcomes

Primary

MeasureTime frameDescription
Proximal Cuff ForceBaselineProximal cuff forces (N) will be measured as participants sit, stand, and walk without a CDO and in each CDO condition.
Peak Plantar ForceBaselinePlantar forces (N) will be measured across the total foot, the hindfoot, midfoot, and forefoot as participants sit, stand, and walk without a CDO and in each CDO condition.
Plantar Force ImpulseBaselinePlantar force impulse (Ns) across the total foot, the hindfoot, midfoot, and forefoot will be calculated using the integral of the force over the stance phase as participants sit, stand, and walk without a CDO and in each CDO condition.
Numerical Pain Rating ScaleBaselinePain will be assessed using a standard 11-point numerical pain rating scale, in which 0 = no pain and 10 = worst pain imaginable
Modified Socket Comfort Score (Comfort)BaselineComfort scores range from 0 = most uncomfortable to 10 = most comfortable

Secondary

MeasureTime frameDescription
Modified Socket Comfort Score (Smoothness)BaselineSmoothness scores range from 0 = least smooth to 10 = most smooth

Countries

United States

Contacts

Primary ContactJason M Wilken, PT, PhD
jason-wilken@uiowa.edu3193356857
Backup ContactKirsten M Anderson, PhD
kirsten-m-anderson@uiowa.edu3193530431

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026