Skip to content

CeraFlex PFO Closure System PMCF Study

CeraFlex PFO Closure System Post-Market Clinical Follow-up Study: A Multi-center, Prospective, Observational, Post-market Study

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06120270
Enrollment
180
Registered
2023-11-07
Start date
2023-11-03
Completion date
2028-12-01
Last updated
2026-06-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patent Foramen Ovale

Keywords

Lifetech, Patent Foramen Ovale, PFO, CeraFlex, CeraFlex PFO, CeraFlex PFO Closure System

Brief summary

The purpose of this study is to compile real-world data on patient outcomes and evaluate the procedural success and performance of the CeraFlex™ PFO Closure System.

Detailed description

This is a multicenter, prospective, observational, single-arm, open-label, post-market Study. The study device is the Lifetech CeraFlex PFO closure system, which is composed of a) CeraFlex PFO Occluder, and b) SteerEase Introducer. The PFO Closure System is indicated for the non-surgical closure of Patent Foramen Ovale (PFO), and the study objective is to collect real-world data on patient outcomes and evaluate the procedural success and performance of the CeraFlex PFO Closure System. The estimated enrollment period is approximately 18 months, and each subject will followed 24 months post-procedure. The assessment schedule at discharge, 1-3 months follow-up, 6 months follow-up, 12 months follow-up, and 24 months follow-up. Electronic Date Capture (EDC) System will be used for this Study.

Interventions

DEVICECeraFlex PFO Closure System

The Lifetech CeraFlex™ PFO occluder device is a percutaneous, transcatheter closure device for the non-surgical closure of Patent Foramen Ovale (PFO).

Sponsors

Lifetech Scientific (Shenzhen) Co., Ltd.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

1. Patient with indication(s) for PFO Occluder Closure in the Instruction For Use (IFU): 1. Confirmed PFO by medical examinations; 2. Associated with recurrent migraine/headache or TIA or cryptogenic stroke. 2. Patient characteristics consistent with the corresponding IFU \& Device Size Selection: 1. Measure the distance from the defect to the aorta root; 2. Measure the distance from the defect to the superior vena cava (SVC) rim; select a device with the radius of the right disc that will not exceed the lesser of these two distances. 3. Patients who are willing to comply with all study procedures and be available for the duration of the study. 4. Patients or legally authorized representative(s) who are willing and capable of providing informed consent.

Exclusion criteria

1. Age \<18 years or Age \>85 years. 2. Patient with a history of ongoing Atrial Fibrillation (AF). 3. Patient with malignancy or other illness where life expectancy is less than 1 year. 4. Patient not covered by a social security scheme. 5. Patients who are participating in an investigational drug or device study currently. 6. Women of childbearing potential who are, or plan to become pregnant during the time of the study (method of assessment upon physician's discretion). 7. Anything that would place the individual at increased risk or preclude the individual's full compliance with or completion of the study. 8. Any contraindication mentioned in the corresponding IFU: 1. Patients known to have intracardiac thrombi, especially left atrial or left atrial appendage thrombi, demonstrated by echocardiography. Patients known to have a bleeding disorder, untreated ulcer, or any other contraindications to aspirin therapy unless another anti-platelet agent can be administered for 6 months. 2. Anatomy in which the CeraFlexTM PFO device of the required size would interfere with intra-cardiac structure or intra-vascular structure, such as a pulmonary vein, or aorta root. 3. Patients whose heart or vein size is too small to allow TEE probing or catheterization. 4. Patients who are in the condition, e.g. active infection, which would cause them to be poor candidates for cardiac catheterization. 5. Patients known to have sepsis within one month prior to implantation, or any systemic infection that cannot be successfully treated prior to device placement. 6. Patients whose heart does not have enough tissue to secure the device. 7. Patients with hypercoagulation disease. 8. Any patient for whom the radius of the device is greater than the distance from the patent foramen ovale to the aortic root or superior vena cava. * No contraindications specified in the SteerEase introducer IFU.

Design outcomes

Primary

MeasureTime frameDescription
Procedural success rateProcedure/at discharge or 7 days post-procedure, whichever comes firstProcedure success is defined as a composite of : 1. absence of peri-procedural stroke-related events (ischemic stroke, cryptogenic stroke, or TIA), device embolization, cardiac or vascular perforation, or death, at discharge or 7 days post-procedure, whichever comes first; 2. successful implantation of the device at the procedure.

Secondary

MeasureTime frameDescription
Residual shuntAt procedure, 6 months and 12 months post-implantationResidual shunt was classified on the basis of the estimated number of microbubbles detected in the left atrium within three cardiac cycles after appearance in the right atrium, as observed on cTTE/cTEE while the patient was at rest or during Valsalva procedure. The presence of 0 microbubbles was classified as no shunt, 1 to 5 microbubbles as small, 6 to 25 microbubbles as moderate, and more than 25 microbubbles as large.
Rate of stroke related eventsFrom attempted procedure up to 24 months post-implantationIschemic stroke, cryptogenic stroke, or TIA
Rate of Device DeficienciesFrom attempted procedure up to 24 months post-implantationIncluding device malfunctions, failures, and non-conformances
Incidence of Serious Adverse EventFrom attempted procedure up to 24 months post-implantationSAE
Incidence of deathFrom attempted procedure up to 24 months post-implantationDeath

Countries

Germany, South Korea

Contacts

CONTACTKadir Shemsi, CTM
Kadirr@lifetechmed.com+86-176-2130-9203
PRINCIPAL_INVESTIGATORMarcus Sandri, Dr

German Heart Center Leipzig

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 11, 2026