Skip to content

Pulse-Width Modulation

Pulse-width Modulation During Pedicle Screw Stimulation

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06120231
Enrollment
50
Registered
2023-11-07
Start date
2023-12-01
Completion date
2027-10-01
Last updated
2026-07-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Spinal Fusion, Spinal Stenosis

Brief summary

The overarching aim of this project is to modulate the pulse-width during stimulation of pedicle screws and record the response thresholds associated with each PWM setting. During this initial phase of the investigation, no further data will be collected.

Detailed description

In vivo electrical stimulation of pedicle screws is a well-documented modality for evaluating potential breach of the pedicle wall. However, previous research has focused primarily on the stimulation threshold intensity required to elicit a neurophysiological response. Other stimulation parameters, such as pulse-width, remain uninvestigated. The goal is to obtain data on the pulse-width vs. CMAP relationship.

Interventions

DIAGNOSTIC_TESTPulse width modulation

Will be stimulating the pedicle screws utilizing three different pulse-width settings, 0.4 milliseconds, 0.2 milliseconds, and 0.05 milliseconds.

Sponsors

Dartmouth-Hitchcock Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* A patient will be eligible for study participation once they have been booked for a surgery involving pedicle screw placement and intraoperative neuromonitoring.

Exclusion criteria

* The study excludes neonates, minors, pregnant women, prisoners and cognitively impaired patients.

Design outcomes

Primary

MeasureTime frameDescription
CMAP response under three different pulse-width settingsWithin operating room upon completion of pedicle screw placement. 1 dayUpon completion of the pedicle screw placements, each screw will be stimulated utilizing three different pulse-width settings, 0.4 milliseconds, 0.2 milliseconds, and 0.05 milliseconds. The stimulation intensity required to elicit a compound muscle action potential (CMAP) will be recorded for each pulse-width parameter. This is measured in microvolts (uV).

Countries

United States

Contacts

CONTACTLauren Sinks, MPH
Lauren.J.Sinks@hitchcock.org6036179909
PRINCIPAL_INVESTIGATORLinton Evans, Dr.

Dartmouth-Hitchcock Medical Center

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 10, 2026