Bradycardia
Conditions
Brief summary
This is an open label, interventional, feasibility, prospective, multicenter, clinical trial of lead extraction. The Xtrac O.S. system is intended for transvenous removal of pacing or defibrillator leads, having an inner lumen, through a superior approach. A total of 15 patients, who are scheduled for CIED lead extraction, will be recruited in order to ensure a total of at least 10 patients finishing the study procedures and follow up.
Interventions
This is an open label, non-randomized, feasibility, prospective, interventional clinical trial of lead extraction. The Xtrac O.S. system is intended for transvenous removal of pacing or defibrillator leads, having an inner lumen, through a superior approach. The decision upon lead extraction will be based upon the applicable Heart Rhythm Society guidelines or European Heart Rhythm Association (EHRA). Each enrolled patient will undergo a pre procedural evaluation to enable planning of the extraction procedure. The evaluation includes an assessment of the CIED components to be removed, dwell time, anatomic course on radiography and patient characteristics that may require management prior to extraction. A multidisciplinary team evaluation involving cardiac surgery, electrophysiologist, and cardiac anesthesiology should allow for a rapid and successful response to major complications
Sponsors
Study design
Intervention model description
Open label, non-randomized, feasibility, prospective, interventional clinical trial of lead extraction. The Xtrac O.S. system is intended for transvenous removal of pacing or defibrillator leads, having an inner lumen, through a superior approach. A total of 10 patients, who are scheduled for lead extraction, will be recruited in order to ensure a total of at least 10 patients finishing the study procedures and follow up. The decision upon lead extraction will be based upon the applicable Heart Rhythm Society guidelines or European Heart Rhythm Association (EHRA). Each enrolled patient will undergo a pre procedural evaluation to enable planning of the extraction procedure. The evaluation includes an assessment of the CIED components to be removed, dwell time, anatomic course on radiography and patient characteristics that may require management prior to extraction.
Eligibility
Inclusion criteria
1. Men or Female patients, 18-85 years old. 2. Patients must understand the procedures and methods of this study and be willing to sign the informed consent form and to complete the trial in strict accordance with clinical trial protocol. 3. Scheduled for a CIED lead extraction upon current guidelines. 4. Lead implant duration more than 1 year and less than 5 years. 5. Patient must be SARS-CoV-2 negative and without Covid-19 signs and symptoms, prior to enrollment. 6. Patients are classified as ASA II/III. 7. Leads with external diameter of 7Fr-9Fr.
Exclusion criteria
1. Patient age \> 85 years old. 2. Hemodynamic instability. 3. Class IV NYHA heart failure. 4. Contrast allergy. 5. Patients felt to be high risk due to degree of acute illness or systemic comorbidities. 6. Patients who are placed on a heparin bridge, and are felt to be high risk for even brief discontinuation of anticoagulation 7. Pregnant or lactating. 8. Participating in another clinical study. Eligibility will be determined by the PI and investigators based on the exclusion/inclusion criteria, current medical status and evaluation of the procedure risks mitigation.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| To evaluate safety related to the lead extraction procedure, or the extraction tool | 0 to 30 days post-lead extraction | To collect and evaluate device- and procedure-related adverse events. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| To assess the ease of use, duration of the procedure and the physician satisfaction by questions by a Likert scale | During procedure | Using Likert scale (1 - Poor; 2 - Fair; 3 - Good; 4 - Excellent) |
| To evaluate the rate of complete procedural success of removal leads implanted for more than 1and up to 5 years | Acute setting (during the surgical procedure) | Complete procedural success is the removal of the targeted lead and all lead material from the vascular space, with the absence of permanently disabling complications or procedure-related death |
| To evaluate the rate of clinical procedural success | Acute setting (during the surgical procedure) | Clinical procedural success is the removal of all targeted leads and all lead material from the vascular space, or retention of a small portion of the lead (fragment that is 4 cm or smaller) that does not negatively impact the outcome goals of the procedure |
Countries