Skip to content

Impact of Cantilever Design on Clinical, Radiographic, and Volumetric Parameters: a Retrospective Study

Impact of Cantilever Design in the Posterior Areas of the Mandible on Clinical, Radiographic, and Volumetric Parameters: a Retrospective Study With 8-year Follow-up

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06104163
Enrollment
27
Registered
2023-10-27
Start date
2015-01-01
Completion date
2023-11-27
Last updated
2024-05-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Partial Edentulism

Brief summary

The present retrospective study aims to evaluate the impact of cantilever design in the posterior areas of the mandible on clinical, radiographic, and volumetric parameters with an 8-year follow-up.

Detailed description

Implant rehabilitation of posterior edentulous areas of the mandible is very complex because the presence of noble structures, such as the inferior alveolar nerve (NAI), often requires major reconstructive procedures to achieve adequate bone volume before implant placement. To overcome these potential problems and provide patients with sufficient function and esthetics, the use of single-unit crowns (SCs) supported by implants with cantilever extensions was introduced. The length and design of cantilever extensions are associated with possible detrimental effects on implant and prosthetic survival. In light of the above, the objective of the present study is to evaluate the impact of cantilever design in the posterior areas of the mandible on clinical, radiographic, and volumetric parameters with an 8-year follow-up.

Interventions

None listed

Sponsors

University of Catania
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Patients aged ≥18 years; * Patients with partial edentulism; * Patients with systemic health or controlled medical conditions; * Patients with healthy or treated periodontal conditions; * Patients enrolled in regular supportive periodontal therapy (SPT); * Patients without clinical signs of oral parafunctions (bruxism or clenching); * Presence of 1 osteointegrated dental implant in posterior region (premolar or molar) of mandible, after transmucosal placement and healing at 3-6 months; * Tissue level solid-screw implants with a sand-blasted and acid etched (SLA) surface with an endosseous diameter of 4.1 mm, a length of 8, 10 or 12 mm, a shoulder diameter of 4.8 mm and a supracrestal machined neck with a height of 1.8 mm (Straumann Dental Implant System, Institute Straumann AG); Use of prefabricated titanium abutments; * Monolithic zirconia SCs manufactured by digital flow; Screwed SCs with a mesial or distal cantilever extension; * Alternative crown design (ACD) with eccentric implant insertion, with crown-like-premolar and with distal or mesial cantilever with ovoid conformation. In the latter case, the lower abutment cross-section in the region between the crown-bridge connector mimics the shape of a root, creating an interradicular access route to facilitate oral hygiene maneuvers; * Absence of occlusal contacts or guidance on the cantilever extension at baseline; * Opposing dentition consisting of natural teeth or fixed or removable restorations; * Availability of periapical radiography at baseline (i.e., loading of SCs) and at the analyzed timings (after 1, 3, 5, and 8 years); * Availability of clinical measurements, such as pocket probing depth (PPD), plaque index (PI), bleeding index at probing (BOP), suppuration at probing (SUP), keratinized mucosa (KM), and mucosal recession (MR) taken at baseline (i.e., at loading of the SCs) and at 8 years after SCs loading, at four sites/implant with a Michigan graded periodontal probe (Deppeler SA); Availability of intraoral scans at baseline (i.e., at loading of the SCs) and at the analyzed time points (after 1, 3, 5, and 8 years after SCs loading) and executed using 3 Shape TRIOS 3, Germany GmbH.

Exclusion criteria

* Untreated or active periodontal diseases; * Type I implant placement; * SCs with cantilever extension replacing mandibular and maxillary incisors and canines; - - SCs with cantilever extension replacing posterior maxillary; * SCs with cantilever extension supported by implants with a diameter ≤3.5 mm; * SCs supported by hollow-screw and hollow-cylinder implants; * Technical complications, such as fractures of implants, abutments, and the prosthetic artifact; * Smoking habit (more than 15 cigarettes/day); * Drug or alcohol abuse; * Uncontrolled systemic diseases that could affect bone remodeling during implant osseointegration; or soft tissue healing (e.g., uncontrolled diabetes mellitus with HbA1c\>7, osteoporosis); * Use of medications that could affect bone remodeling during implant osseointegration or soft tissue healing (e.g., steroids, antiresorptive medication, radiotherapy); * Autoimmune and/or inflammatory diseases affecting the oral cavity; * Neurological or psychiatric handicap that could interfere with oral hygiene; * Pregnancy or lactation periods.

Design outcomes

Primary

MeasureTime frameDescription
Plaque Index (PI)8 yearsEvaluation of Plaque index (PI), expressed as the percentage of positive sites and measured at 4 implant sites (mesio-buccal, mesio-oral, disto-buccal and disto-oral) throught Michigan-grade periodontal probe.
Mucosal recession (MR)8 yearsMucosal recession (MR), of the peri-implant soft tissue, measured from the restoration margin to the mucosal margin and expressed in mm. Coronal from restoration margin is defined as (+) and apical from restoration margin defined as (-);
Bleeding and/or suppuration on probing (BOP/SUP)8 yearsEvaluation of Bleeding and/or suppuration on probing (BOP/SUP), within 30 seconds after probing and expressed as the percentage of positive sites and measured at 4 implantation sites (mesio-buccal, mesio-oral, disto-buccal and disto-oral).
Probing Depth of the Peri-implant Pocket (PPD)8 yearsIt is measured from the mucosal margin to the bottom of the probable peri-implant sulcus and expressed in mm.
Keratinized mucosa (KM)8 yearsEvaluation of Keratinized mucosa width (KM), measured from the restoration margin to the mucogingival junction and expressed in mm.

Secondary

MeasureTime frameDescription
Radiographic examination at baseline and after 8 years of follow-up8 yearsAll patients enrolled in the study underwent periapical radiography performed with the long parallel cone technique at baseline and 8 years after. The measure linear peri-implant marginal bone levels (BML) of single unit crowns (SCs) is the perpendicular distance, expressed in mm, from the mesial and distal edge of the implant shoulder to the first bone-to-implant contact (BIC).
Volumetric analysis at baseline and after 8 years of follow-up8 yearsIt was obtained by superimposing the intraoral scans of each patient, performed at baseline and eight years later through an optical scanner (3 Shape TRIOS 3 Germany GmbH), using 3D imaging software. The volumetric differences affecting the peri-implant soft tissues following prosthetic loading were expressed as a percentage and in mm3.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026