Skip to content

Safety and Effectiveness of TaurusTrio™ Heart Valve System in Patients With Severe Aortic Regurgitation (AR)

A Prospective, Multicenter, Single-group Clinical Study to Evaluate the Safety and Efficacy of Peijia Medical Transcatheter Aortic Valve System in the Treatment of Severe Aortic Valve Regurgitation

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06101888
Enrollment
116
Registered
2023-10-26
Start date
2023-08-01
Completion date
2029-07-31
Last updated
2024-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Regurgitation

Brief summary

To evaluate the safety and effectiveness of the TaurusTrio™ Heart Valve System in a patient population with symptomatic severe AR requiring replacement/repair of their native aortic valve that are at high risk for open surgical aortic valve replacement/repair (SAVR).

Interventions

DEVICETaurusTrio™ Heart Valve System

The TaurusTrio™ Heart Valve System contains the following sub-components: a prosthetic transcatheter porcine pericardial aortic valve, 20Fr Introducer Sheath System, transfemoral Delivery Catheter, and Loading Tool.

Sponsors

Peijia Medical Technology (Suzhou) Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients who voluntarily participate and sign the informed consent and are able to comply with the entire trial process; * Age ≥ 18 years; * Adult subjects with severe AR (Grade ≥ 3) as assessed by echocardiography based on ASE (American Society of Echocardiography) using multiparametric approach with: * Jet width ≥ 65% of LVOT * Vena contracta width of \> 6 mm * Holodiastolic flow reversal in proximal abdominal/descending aorta * Jet deceleration rate/Pressure half time \<200ms * AND, For Grade 3: * Regurgitant volume ≥ 45-59 ml/beat * Regurgitant fraction ≥ 40-49% * EROA ≥ 0.2-0.29 cm2 * OR, For Grade 4: * Regurgitant volume ≥ 60 ml/beat * Regurgitant fraction≥50% * EROA ≥ 0.3 cm2 Note: In cases where not all criteria listed for severe AR are met, the Core Lab will determine severity. Supplemental CMR imaging may be used to substantiate the degree of AR reported by Core Lab on baseline echo when imaging is suboptimal, Doppler parameters are discordant or inconclusive regarding the severity of AR, or when a discrepancy is present between the echo findings and the clinical setting. * Patients who have symptoms obviously caused by Aortic Regurgitation, such as dyspnea, chest pain, NYHA Class II or higher; * Patients who are unsuitable for conventional surgery but needs TAVR(It is recommended to refer to the 2020 ACC/AHA Heart Valve Disease Management Guidelines when evaluating the risks of surgical valve surgery),evaluated by the cardiac team (including at least one interventional cardiologist and one cardiovascular surgeon) * Patient has suitable anatomy to accommodate the insertion and delivery of the JenaValve Trilogy™ Heart Valve System,evaluated by core laboratory;

Exclusion criteria

* Congenital uni- or bicuspid aortic valve morphology; * Previous prosthetic aortic valve (bioprosthesis or mechanical) implant; * Mitral regurgitation or Tricuspid regurgitation\> moderate; * Clinically significant coronary artery disease (CAD) requiring revascularization within 30 days prior to index procedure, or planned CAD revascularization procedure within 12 months after index procedure; * Echocardiographic evidence of left ventricular thrombus; * Endocarditis within 180 days prior to index procedure; * Hypertrophic cardiomyopathy with or without obstruction; * Severe pulmonary hypertension (systolic PA pressure \>80 mmHg); * Severe RV dysfunction as assessed clinically and by echo; * Severely reduced left ventricular ejection fraction (LVEF \<25%); * Aortic annular perimeter derived diameter of \<21.0 mm or \> 28.6 mm or perimeter \<66.0 mm or \>90 mm (assessed by Multi-Detector CT measurement); * Aortic annulus angulation \> 70° (assessed by Multi-Detector CT measurement); * Straight length of ascending aorta of \< 55 mm; * Significant disease of ascending aorta, including ascending aortic aneurysm ; (defined as maximal luminal diameter of 50 mm or greater) or atheroma (including if thick \[\>5 mm\], protruding or ulcerated) * Need for urgent or emergent TAVR procedure for any reason; * Cardiogenic shock or hemodynamic instability requiring inotropic support or ventricular assist device within 30 days prior to index procedure; * Myocardial infarction \< 30 days prior to index procedure; * Cerebrovascular event (TIA, stroke) \< 180 days prior to index procedure; * Patients with common carotid artery or internal carotid artery or vertebral artery stenosis (\>70%); * Patients with severe coagulopathy; * Severe renal insufficiency (GFR \< 30 ml/min) at Screening, OR renal disease requiring renal replacement therapy within 180 days prior to index procedure; * Blood dyscrasias as defined: leukopenia (WBC \< 3000/mm³), or thrombocytopenia (platelets \< 90,000/µl) or anemia (Men: Hgb \< 8.1 g/dl; Women: Hgb \< 7.4 g/dl); * Active peptic ulcer or upper gastrointestinal bleeding \< 90 days prior to index procedure; * Known allergies to to heparin, aspirin, ticlopidine, Clopidogrel, Nitroglycerin and other drugs,contrast agents, nitinol shape memory alloy, tantalum or porcine products; * Contraindication to intraoperative transesophageal echocardiography and/or Multi-Detector CT (MDCT) scan; * Estimated life-expectancy of \< 24 months; * Patient is enrolled in another investigational medical device or drug study which has not completed the required primary endpoint follow-up. (Note: Patients involved in a long-term surveillance phase of another study are eligible for enrollment in this study); * Other medical, social, or psychological conditions that in the opinion of an Investigator precludes the patient from providing appropriate informed consent; * Severe dementia (resulting in either inability to provide informed consent for the trial/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up assessments); * Unable to comply with follow-up requirements;

Design outcomes

Primary

MeasureTime frameDescription
All-cause mortality at 12 months12 monthsAll-cause mortality

Secondary

MeasureTime frameDescription
Improvement in quality of life (QoL) at 12 months over baseline, as measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ).12 monthsImprovement in quality of life (QoL)
Composite safety endpoint at 30 days30 days after procedureall-cause death;all stroke; life-threatening or major bleeding;acute kidney injury (AKI) stage 2, 3 or dialysis;major vascular complications;surgery/intervention related to the device (including coronary intervention);permanent pacemaker implantation;moderate or severe total aortic regurgitation

Other

MeasureTime frameDescription
Technical Success at exit from OR, hybrid room or cath lab post-index procedureImmediate after procedureAbsence of procedural mortality; and Successful access, delivery, and retrieval of transcatheter delivery system; and Deployment and correct positioning of a single intended THV; and Freedom from re-intervention related to the device or access procedure
Device Success at 1-month consisting of30 days after procedureAbsence of procedure mortality; and Correct position of a single prosthetic heart valve Intended performance of the prosthetic heart valve (i.e., no prosthesis mismatch and mean aortic valve gradient \<20 mmHg or peak velocity \<3 m/s; and no moderate or severe prosthetic valve regurgitation) Intended performance of the prosthetic heart valve (i.e., no prosthesis mismatch and mean aortic valve gradient \<20 mmHg or peak velocity \<3 m/s; and no moderate or severe prosthetic valve regurgitation)
Procedural Success at 1-month consisting of30 days after procedureDevice success at 30 days; and No device- or procedure-related serious adverse events (defined as below): i) No disabling or non-disabling stroke ii) No life-threatening bleeding (\>4 units PRBC) iii) No acute kidney injury - Stage 2 or 3 (including dialysis) iv) No major vascular complication v) No myocardial infarction or cardiac ischemia requiring PCI or CABG vi) No valve-related dysfunction requiring repeat procedure (BAV, TAVI, or SAVR)

Countries

China

Contacts

Primary Contactjing ren
renjing@peijiamedical.com18550112597

Outcome results

None listed