Skip to content

Clinical Pilot Study of the Percutaneous Ultrasound Jejunostomy Procedure

A Single Center, Pilot Study to Evaluate the Feasibility of the Percutaneous Ultrasound Jejunostomy (PUJ)

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06095804
Enrollment
10
Registered
2023-10-23
Start date
2023-12-01
Completion date
2025-07-01
Last updated
2023-10-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Enteral and Supplement Feeds Adverse Reaction, Jejunostomy; Complications, Safety Issues

Keywords

Jejunostomy, Enteral Feeding, Long-term Enteral Nutrition

Brief summary

The purpose of this study is to evaluate the feasibility and performance of the Percutaneous Ultrasound Jejunostomy (PUJ) procedure that utilizes a novel device (PUMA-J System) in conjunction with widely available ultrasound technology and endoscopic guidance. The procedure will be performed in up to 10 eligible subjects. Patients will be followed for 2 days following performance of PUJ to assess for potential complications.

Detailed description

Jejunostomy tubes (J-tubes) provide a path for nutrition delivery directly into the small intestinal lumen, bypassing the mouth, esophagus, and stomach for patients who have difficulty with proximal gut feeding. Many medical conditions may require J-tubes, including cancers, gastroparesis, and patients with high risk of aspiration. A recent innovation by CoapTech addresses technical and procedural limitations of current jejunostomy tube placement methods by leveraging ultrasound for visualization and magnets for control of the jejunal loop. The Percutaneous Ultrasound Magnet Aligned (PUMA) System enables clinicians to affix jejunal loops superficially via magnetic coaptation and visualize the planned stomal tract using ultrasound. The purpose of this pilot clinical study is to test the feasibility of the PUMA-Jejunostomy (PUMA-J) System in adults requiring a jejunostomy tube. This is a single-center, non-randomized, non-blinded feasibility study to evaluate the performance and safety of the PUJ procedure that utilizes a novel device (PUMA-J System).

Interventions

DEVICEPercutaneous Ultrasound Jejunostomy

Placement of a jejunostomy tube using the PUMA-J System

Sponsors

University of Maryland, Baltimore
CollaboratorOTHER
CoapTech
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Informed consent must be obtained before any study-specific assessment is performed * Male or female \> 21 years of age * Estimated tract length (skin to anterior abdominal wall) \<= 4.5cm on prior imaging * Indication for percutaneous jejunostomy tube placement determined to be present by the primary clinical care team (examples below): * High aspiration risk * Malnourished- chronically ill and/or neurologically impaired requiring jejunal feeding for \>30 Days. * Neoplasia (stomach and esophagus) * Gastric and duodenal obstruction * Gastrointestinal dysmotility (gastroparesis) * Altered anatomy (gastric-esophageal surgeries) * Other indication deemed to be appropriate by the study team * Patient determined to be an appropriate candidate for percutaneous jejunostomy by the study team * Women of childbearing potential must have negative serum or urine pregnancy test during the current hospitalization

Exclusion criteria

* Temperature ≥ 38 C * Systolic BP \< 90 or \> 180 mmHg * Heart Rate \< 50 or \> 120 * Presence of a contraindication to being in proximity to a magnet (e.g. pacemaker) * History of prior major abdominal surgery * Patients with HgB \< 7g/dL, or fluid resuscitated within 48hrs prior, or history of life-threatening gastrointestinal bleeding within 1 month * Pregnant or nursing (lactating) women * Involvement in other investigational trials within 30 days prior to screening * Absolute contraindications: * Sepsis * Severe ascites * Peritonitis * Coagulopathy (international normalized ratio (INR) greater than 1.5 or a platelet count of less than 50,000/uL) * Abdominal wall infection at the site of planned tube insertion * Interposed organs as determined by imaging * Abnormal upper gastrointestinal anatomy (e.g., partial or Total gastrectomy, Esophageal strictures) * Inflammatory, or infiltrative diseases of the small bowel and/or anterior abdominal wall. * Other standard general contraindications to endoscopy * Pacemakers or other electronically active implantable devices * Small bowel fistula * Any other medical condition(s) that may put the patient at risk or influence study results in the investigator's opinion, or that the investigator deems unsuitable for the study.

Design outcomes

Primary

MeasureTime frameDescription
Procedural SuccessProcedure timeframeRate of procedural success in completing jejunostomy tube placement using the PUMA-J System

Secondary

MeasureTime frameDescription
Procedural AbortsProcedure timeframeDescription of occurrences of procedure abort
Device Related Serious Adverse Events48 hours of procedure performanceRate of Device Related Adverse Events following Jejunostomy procedure
Adverse Events48 hours of procedure performanceRate of all Adverse Events following Jejunostomy procedure
Rate of inadvertent puncture of vital organsProcedure timeframeDescription of occurrences of inadvertent puncture of vital organs during performance of procedure
Requirement for salvage surgery due to complication of the procedure48 hours of procedure performanceDescription of occurrences of salvage surgery performed due to complication of procedure

Countries

United States

Contacts

Primary ContactClinical Trials
regulatory@coaptech.com443 574 6934

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026