Skip to content

Traditional Chinese Medicine Ultrasonic Atomization Treatment for Dry Eye Disease

Traditional Chinese Medicine Ultrasonic Atomization Treatment for Dry Eye Disease: A Randomized, Double-masked, Placebo-controlled Trial

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06089317
Enrollment
200
Registered
2023-10-18
Start date
2024-07-28
Completion date
2025-06-22
Last updated
2026-03-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dry Eye Syndromes

Keywords

Dry Eye Syndromes, Traditional Chinese Medicine, Ultrasonic Atomization, Randomized Controlled Trial

Brief summary

Dry eye disease (DED) is the most prevalent ocular surface disease worldwide. Standard treatments like artificial tears show limited effect. Regarding the ultrasonic atomization, the ultrasonic nebulizer produces consistent steam from the solution with a treatment effect delivered to the ocular surface. We aim to evaluate the effectiveness and safety of traditional Chinese medicine (TCM) ultrasonic atomization as an adjuvant treatment for DED. This is a randomized double-masked, active- and placebo-controlled trial. 200 subjects will be equally assigned to the herbal compound decoction(CD) group, dendrobium caulis (DC) group, houttuynia cordata (HC) group, placebo atomization(PA) group, and artificial tear (AT) group by stratified permuted block randomization. Subjects of CD, DC, HC, and PA groups will receive TCM ultrasonic atomization treatment (6 times/week). All patients will receive hypromellose 0.3% w/v lubricant eye drops for a 1-week wash-out and a 4-month follow-up period. Outcomes included non-invasive tear break-up times, corneal and conjunctival fluorescein staining, and other dry eye-related parameter examined by LipiView II Ocular Surface Interferometer, OCULUS® Keratograph 5M, and slit lamp biomicroscope evaluated by masked clinical assessors at baseline, week 1, 2, 3, 4 and month 2, 3, 4. The other subjective questionnaires like the Ocular Surface Disease Index (OSDI) questionnaire are also selected.

Interventions

DRUGTCM ultrasonic atomization treatment with herbal Compound Decoction (CD)

The subjects will receive TCM ultrasonic atomization treatment with the ultrasonic nebulizer (WH-2000, YueHua, China) 6 days a week, once daily, 10 minutes per session, for 4 weeks. The solution for atomization of the CD group is TCM compound decoction. The prescription of atomization solution in the CD group contains Honeysuckle flower (金銀花) 5g, Chrysanthemum flower (菊花) 5g, Pale betterflybush flower (密蒙花) 5g, Mild mint herb (薄荷) 5g, Barbary wolfberry fruit (枸杞子) 10g, and Ophiopogon japonicus (麥冬) 5g. Subjects will be treated with hypromellose 0.3% w/v eye drops four times per day too.

DRUGTCM ultrasonic atomization treatment with Dendrobii Caulis (DC)

The subjects will receive TCM ultrasonic atomization treatment with the ultrasonic nebulizer (WH-2000, YueHua, China) 6 days a week, once daily, 10 minutes per session, for 4 weeks. The solution for atomization of the DC group is Dendrobii Caulis extracts. The prescription of the DC group contains Dendrobium (石斛) 35g. Subjects will be treated with hypromellose 0.3% w/v eye drops four times per day too.

DRUGTCM ultrasonic atomization treatment with Houttuynia Cordata (HC)

The subjects will receive TCM ultrasonic atomization treatment with the ultrasonic nebulizer (WH-2000, YueHua, China) 6 days a week, once daily, 10 minutes per session, for 4 weeks. The solution for atomization of the HC group is Heartleaf Houttuynia Herb extracts. The prescription of the HC group contains Heartleaf Houttuynia Herb(魚腥草) 35g. Subjects will be treated with hypromellose 0.3% w/v eye drops four times per day too.

DRUGPlacebo TCM ultrasonic atomization treatment (PA)

The subjects will receive TCM ultrasonic atomization treatment with the ultrasonic nebulizer (WH-2000, YueHua, China) 6 days a week, once daily, 10 minutes per session, for 4 weeks. The solution for atomization of the PA group is low-concentration compound decoction (5%) same with the CD group. Subjects will be treated with hypromellose 0.3% w/v eye drops four times per day too.

The subjects will receive lubricant eye drop (Hypromellose 0.3% w/v Eye Drops) four times per day only.

Sponsors

Chinese University of Hong Kong
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Intervention model description

A total of 200 subjects with mild to moderate DED will be recruited. Only one eye of recruited subjects with the shorter NIBUT will be selected and analyzed as the study eye. The subjects will be randomly divided into TCM compound decoction (CD) group, dendrobium caulis (DC) group, houttuynia cordata (HC) group, placebo atomization (PA) group, and artificial tears (AT) group equally. An online-based clinical trial randomization tool with a permuted block and stratification randomization method is applied for the randomization, and block sizes are randomly chosen. Stratification variances is sex and age.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. At least one eye of subjects meets DED diagnostic criteria as the Tear Film and Ocular Surface Society (TFOS) Dry Eye Workshop (DEWS II); and 2. Ocular Surface Disease Index (OSDI)≥13 and \<33; and 3. The age range between years 18-80, no sex limitation; and 4. Symptoms of dry eye for at least 6 months; and 5. Can complete the questionnaires independently and understand Chinese or English.

Exclusion criteria

1. Had or currently suffering from other concomitant ocular surface diseases, including chronic conjunctivitis, ocular rosacea, cicatricial pemphigoid, graft-versus-host disease, limbal stem cell deficiency, and severe ocular allergy; 2. Received any refractive surgery and corneal surgery before, including corneal transplant; or any eye surgery in the past 6 months; 3. Receiving DED-related medications, including topical steroid eyedrops, topical antibiotics, topical cyclosporin A, and topical diquafosol; 4. Received intense pulsed laser (IPL) or vectored thermal pulsation (VTP) therapy in the past 12 months; 5. Received topical antiglaucomatous treatment in the past 12 months 6. Plans to use contact lenses during treatment and follow-up periods or used contact lenses 2 weeks before the baseline measurement and recruitment; 7. Had or currently suffering from severe cardiopulmonary disease, liver and kidney dysfunction, and severe blood system diseases; 8. Suffering from glucose-6-phosphate dehydrogenase deficiency (G6PD); 9. Had or currently suffering from specific respiratory diseases, e.g. emphysema, bronchitis, asthma, chronic obstructive pulmonary disease, bronchial dilatation; 10. Has adverse reaction history to herbs used in this study before; 11. Whose TCM constitution is manifested as "yang-deficiency" or diagnosed by TCM practitioners that their TCM syndrome is not suitable for the atomization treatment; 12. Pregnancy, preparation for pregnancy, or lactation;

Design outcomes

Primary

MeasureTime frameDescription
Change in the Ocular Surface Disease Index (OSDI)baseline to 4th weekThe Ocular Surface Disease Index (OSDI) is a 12-item symptom frequency-based questionnaire. It is self-administered to assess DED-related symptoms and severity. The final OSDI score is calculated by dividing the product of the total sum of the score and 25 by the total number of answered questions, with a range from 0 to 100. The score reflects the severity of DED(normal: 0-12, mild: 13-22, moderate: 23-32, severe: \>33).
Change in Non-invasive Tear Break-up Times (NIBUT)baseline to 4th weekThe non-invasive tear break-up time (NIBUT) will be measured by the OCULUS Keratograph® 5M (Oculus, Wetzlar, Germany). Subjects will be instructed to keep their eyes on as much as possible during the examination. First and average NIBUT will be recorded by the machine accordingly. Shortening NIBUT(\< 10 seconds) suggests instability of the tear film.

Secondary

MeasureTime frameDescription
Change in Ocular Surface Disease Index (OSDI)4 monthsThe Ocular Surface Disease Index (OSDI) is a 12-item symptom frequency-based questionnaire. It is self-administered to assess DED-related symptoms and severity. The final OSDI score is calculated by dividing the product of the total sum of the score and 25 by the total number of answered questions, with a range from 0 to 100. The score reflects the severity of DED: normal: 0-12, mild: 13-22, moderate: 23-32, severe: \>33).
Change in symptom Assessment iN Dry Eye (SANDE, modified)4 monthsSymptom Assessment iN Dry Eye (SANDE) questionnaire is a 2-item frequency- and severity-based visual analog scale. It is self-administered to evaluate the frequency and severity of dry eye symptoms. The final SANDE score is calculated by obtaining the square root of the product of the frequency of symptoms score and the severity of symptoms score, with a range from 0 (minimal degree of dry eye symptoms) to 100 (maximal degree of dry eye symptoms)
Change in 36-Item Short Form Health Survey (SF-36)4 monthsThe 36-Item Short Form Health Survey (SF-36) is a 36-item self-administered questionnaire, with 8 domains included: physical functioning (PF), role physical (RP), bodily pain (BP), general health (GH), vitality (VT), social functioning (SF), role emotional (RE), and mental health (MH). The physical health sub-scale and Mental health sub-scale will be graded respectively.
Change in the Work Productivity and Activity Impairment Questionnaire: General Health V2.0 (WPAI:GH)4 monthsThe Work Productivity and Activity Impairment Questionnaire: General Health V2.0 (WPAI: GH) is a 6-item questionnaire that measures impairments in work and activities.
Change in Non-Invasive Tear Break Up Times (NIBUT)4 monthsNon-Invasive tear break up time (NIBUT) will be measured by the OCULUS Keratograph® 5M (Oculus, Wetzlar, Germany) in both eyes. Participants were instructed to keep their eyes on as much as possible during the examination. First and average NIKBUTs will be recorded by the machine. Shortening NIBUT(\< 10 seconds) suggests instability of the tear film.
Changes in Tear Meniscus Height (TMH)4 monthsThe tear meniscus height (TMH) will be measured by the OCULUS Keratograph® 5M (Oculus, Wetzlar, Germany).
Changes in Bulbar Redness4 monthsBulbar conjunctival hyperaemia is automatically evaluated the Keratograph 5M (OCULUS, Wetzlar, Germany) according to the JENVIS grading scale from 0 to 4.
Changes in Lipid Layer Thickness4 monthsThe lipid layer thickness (LLT) of the tear film will be determined with the LipiView ® II Ocular Surface Interferometer (TearScience, Morrisville, NC). Minimum, Maximum, and Average thickness in nanometers (nm) will be measured.
Changes in Partial Blinking Rate4 monthsThe partial blinking rate will be reported as the percentage of incomplete blinks. The total and partial blinking times will be automatically recorded by the LipiView ® II Ocular Surface Interferometer (TearScience, Morrisville, NC).
Changes in Meiboscore4 monthsThe meiboscore grading will be based on the infrared meibography captured by the LipiView ® II Ocular Surface Interferometer (TearScience, Morrisville, NC). Both superior and inferior eyelids will be recorded. The result will be graded by a masked assessor. The grading scheme is a 3-point scale (grade 0, no meibomian gland atrophy; grade 1, less than 1/3 area of glands lost; grade 2, 1/3-2/3 area of glands lost; grade 3, more than 2/3 area of glands lost)
Change in Tear Film Breakup Time (TBUT)4 monthsThe tear film breakup time (TBUT) is the time of the initial breakup of the tear film after a full blink. 2% Sodium fluorescein will be instilled in both eyes of the subjects. A masked follow-up assessor will do the examination via the slit lamp with a blue cobalt light. The TBUT will be measured three times with a stopwatch and taken on average.
Change in Corneal and Conjunctival Fluorescein Staining4 monthsFluorescein sodium liquid will be instilled on the ocular surface. After 3 minutes, the corneal and conjunctival punctate epithelial erosions will be observed and graded via the slit lamp biomicroscope with a blue cobalt light. The Oxford Grading System is selected for grading. The severity will be divided into 6 grades (Grade 0, absent; Grade 1, minimal; Grade 2, mild; Grade 3, moderate; Grade 4, marked; Grade 5, severe)
Change in Expressibility of Meibomian Glands in the Meibomian Glands Yielding Liquid Secretion (MGYLS) (the inferior eyelid)4 monthsExpressibility of the inferior eyelid meibomian glands is assessed with the Meibomian Gland Evaluator (TearScience, North Carolina, USA) applied inferior to central aspects of the inferior eyelid margin. The result is graded by a masked assessor. The meibomian glands yielding liquid secretion (MGYLS) is the total number of glands that yield lipid secretions at the central aspects of the eyelid margin.
Change in Quality of Expressed Meibum4 monthsThe meibomian gland evaluator will be applied to the central aspects of the inferior eyelid margin. The result will be graded by a masked assessor. Each gland in each area will be assessed for expressibility and graded according to a 4-point scale: grade 0, no secretion; grade 1, inspissated/ toothpaste-like expression; grade 2, cloudy fluid secretion; and grade 3, clear fluid/normal secretion. The sum scores of 5 glands will be between 0 and 15.
Change in Lid Margin and Eyelash Abnormalities4 monthsLid margin and eyelash abnormalities will be accessed by a slit lamp, including telangiectasia, meibomian gland capping, Demodex lash cylindrical collarettes, staphylococcal lash crusting, and seborrheic lash crusting. All items will be graded based on a four-point scale: grade 0, absent; grade 1, mild; grade 2, moderate; grade 3, severe.
Change in Tear Film Osmolarity (TFO)4 monthsThe tear film osmolarity (TFO) is measured by the ScoutPro™ Osmolarity System (TearLab , San Diego, CA) via the disposable test card in both eyes. The normal osmolarity was considered as lower than 308 mOsm/L in both eyes. A difference more than 8 mOsm/L between two eyes reflects the stability of the tear film.
Changes in Schirmer I test4 monthsThe Schirmer I test (ST) will be performed by sterile standard filter paper strips without anesthesia. The filter paper strips will be gently put on the temporal side of both lower eyelids for 5 minutes. The wetting length by tears in each strip will be recorded in nanometers (mm) by a masked assessor. The strips will be collected in sterile centrifuge tubes respectively for further laboratory tests.
Changes in Matrix metallopeptidase 9 (MMP-9)4 monthsThe MMP-9 enzyme-linked immunosorbent assay (ELISA) development kit (Invitrogen, Carlsbad, CA)) will be applied for measurement of the concentration of MMP-9 in participants' tears.
Adverse events (AEs)4 monthsThe adverse events (AEs) will be the number of incidents based on a checklist of symptoms, signs, and diseases by patients' reporting, slit-lamp examination, or doctor's diagnosis.

Countries

Hong Kong

Contacts

PRINCIPAL_INVESTIGATORKelvin KL Chong, MBChB

Chinese University of Hong Kong

Outcome results

None listed