Skip to content

Carotid Artery Corrected Flow Time and Fluid Responsiveness in Geriatric Patients

Reliability of Carotid Artery Corrected Flow Time Predicting Fluid Responsiveness in Geriatric Patients.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06087250
Enrollment
40
Registered
2023-10-17
Start date
2023-08-01
Completion date
2023-10-24
Last updated
2024-04-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Common Carotid Artery, Fluid Responsiveness

Keywords

fluid responsiveness, carotid blood flow, carotid corrected flow time

Brief summary

Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.

Detailed description

Doppler ultrasound of the common carotid artery has begun to be used as a potential non-invasive tool for assessing hemodynamic status. Its non-invasive nature, ability to be applied independently of the patient's position, ease of application due to the superficial location of the carotid artery, and resistance to intrathoracic pressure changes are among its advantages. Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. Additionally, the velocity time integral (VTI) measuring blood flow through the carotid artery during systole, when multiplied by the cross-sectional area of the carotid artery, allows for the determination of flow within the carotid artery. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.

Interventions

None listed

Sponsors

Marmara University
Lead SponsorOTHER

Study design

Observational model
CASE_CROSSOVER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
65 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* geriatric patient (older than 65 years of age) having surgery under general anesthesia

Exclusion criteria

* Common carotid artery stenosis, common carotid artery disease

Design outcomes

Primary

MeasureTime frameDescription
carotid corrected flow time (cFT)1 hourthe ability ofc FT to predict fluid responsiveness

Secondary

MeasureTime frameDescription
cutt-of value of cFT1 hourthe cutt-of value of cFT to predict fluid responsiveness

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026