Skip to content

Evaluation of Performance of New IFIS Sleeve

Hydrodissection Sleeve to Aid Cataract Surgery

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06067360
Enrollment
20
Registered
2023-10-04
Start date
2024-02-29
Completion date
2024-11-30
Last updated
2023-10-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Brief summary

A silicone sleeve will be used on the hydrodissection needle to avoid that the iris can prolaps through the gap between needle and incision wound.

Detailed description

Cataract surgey is a common operation approximately 25 million pocedures per year worldwide. An essential step of the procedure is hydrodissection where fluid is forced into the eye through a cannula to free the cataract from its capsule. A serious and potential sight threatening complication of hydrodissection is iris prolapse, where the iris comes out of the wound. The overall incidence of iris prolapse during cataract surgery is 0.9% and higher in patients with intraoperative floppy iris syndrome (IFIS) at 11.9% , small pupils and small eyes. Patients on Tamsulosin medication with a Full Set of Project Data IRAS Version 6.3.3 5 DRAFT pupil less than 7.5mm have a 79% risk of prolapse Iris prolapse most often occurs during hydrodissection because the hydrodissection cannula is smaller (approx.1mm) than the wound (2.2-2.7mm) it is introduced through. Therefore the iris can be forced out / prolapse through this gap by the forced injection of fluid. Traditional methods such as phenylephrine injection into the eye have varying effects can be unlicensed and possibly increase the prolapse risk. Mechanical pupil stretching can permanently damage the iris with complications. Phacosleeve hydrodissection where the wound is sealed by a phacosleeve and the hydrodissecting irrigation cannula introduced through the sleeve or from side port /incison. The phacosleeve is not designed for this. This study is to use a purpose made tapered sleeve by Medicel in the same fashion as the current phacosleeve.

Interventions

DEVICEIFIS sleeve

IFIS sleeve will be inserted to prevent iris prolapse

Sponsors

Medicel AG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patient with planned cataract surgery

Exclusion criteria

* pregnant woman

Design outcomes

Primary

MeasureTime frameDescription
performance of IFIS sleeve to prevent iris prolapseThe evaluation of the device is during cataract surgery, which typically is less than 10 minutes. No additional treatments or evaluations after the surgery.performance of the IFIS sleeve to successfully prevent from iris prolapse: Iris prolaps is a distinct complication that can occurr during cataract surgery. For each treatment, the surgeon will protocol, whether a prolaps occurred during the surgical procedure. The primary outcome is the number of prolaps cases over all surgeries.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026