Skip to content

Total Small Bowel Length Measurement Using Computed Tomography and Magnetic Resonance Imaging in Obese Patients

Set up and Validation of Total Small Bowel Length Measurement Using Computed Tomography and Magnetic Resonance Imaging With 3D Reconstruction and Artificial Intelligence Tool in Obese Patients Candidates to Metabolic Surgery

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06065917
Acronym
SBOM-AI
Enrollment
195
Registered
2023-10-04
Start date
2024-01-02
Completion date
2026-02-28
Last updated
2024-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bariatric Surgery Candidate, Obesity

Keywords

obesity, artificial intelligence, computed tomography, bariatric surgery, small bowel lenght, metabolic surgery, magnetic resonance

Brief summary

The aim of the study is to set up and validate a reliable and reproducible automated method using preoperative radiological imaging to measure the TSBL in patients undergoing laparoscopic bariatric/metabolic surgery.

Detailed description

The total length of the small intestine (TSBL) represents a crucial parameter for obtaining a safe and successful minimally invasive surgery in metabolic/bariatric bypass surgery. Nowadays, the standard of small intestine measurement is the intraoperative measurement. Laparoscopy represents the standard approach for baratric/metabolic, making the TSBL measurement time-consuming and risky in case of intestinal lesions. An accurate and effective non-invasive preoperative measurement of the TSBL will allow to evaluate the variability of the TSBL, which affects the surgical strategy. Cross-sectional imaging could play an important role in this setting thanks to the possibility of measuring in a non-invasive way the TSBL. Some studies performed with both Computed Tomography (CT) and Magnetic Resonance (MR) report promising results. However, they are limited by the small size of the sample, the lack of standardized technique and the lack of an automatic method based on Artificial Intelligence (AI). The evaluation of a reliable preoperative method to measure TSBL using cross-sectional imaging will potentially reduce intraoperative complications and insufficient long-term weight loss or nutritional deficiencies. In this scenario a possible solution could be the implementation of analysis method through the development of an AI algorithm capable of automatically segmenting the small intestine. The PRIMARY END POINT of this study is to set up and validate a reliable and reproductible automatic method to measure the TSBL in patients candidates for laparoscopic bariatric/metabolic surgery, based on preoperative radiological imaging The main phases of the project will be: 1. evaluate the feasibility of preoperative CT and MRI-base measurement of the TSBL in a large cohort of obese patients and compare radiological measurement with intraoperative laparoscopic measurement (method of elongation) as a reference standard (1). 2. Evaluate the more accurate cross-sectional imaging between CT and MRI to measure the length of the small intestine. 3. Build an AI tool that can automatically measure TSBL on transversal slice imaging. Three high-volume Italian centers will enroll 195 obese patients who are candidates for metabolic surgery for obesity. Part of them will be established training cohort (total = 105 patients), used to set up the AI-based method of TSBL measurement. The other 90 patients (30 for each center) will represent the validation cohort.

Interventions

DIAGNOSTIC_TESTMeasurement of the total small bowel length using CT scan and MRI with 3D reconstruction and AI tool

The intervention consists in performing CT and MR imaging with small bowel length measurement before bariatric/metabolic surgery in obese patients. Then, during surgery the patients will undergo laparoscopic stretched small bowel measurement as the reference gold standard method to measure the small bowel length. The imaging of the training cohort will be used to trained an AI to set up an automatic method of small bowel length measurement via the analysis of CT and MRI imaging.

Sponsors

University of Padova
CollaboratorOTHER
Federico II University
CollaboratorOTHER
University of Roma La Sapienza
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* BMI \> 35 kg/m2 and at least one obesity-related comorbidity * BMI \> 40 kg/m2 * failure of at least six months of dietary and/or medical treatment of obesity * indication for intervention validated after multidisciplinary evaluation in a specific board meeting

Design outcomes

Primary

MeasureTime frameDescription
Concordance between AI-based total small bowel length measure and laparoscopic total small bowel length measure1 monththe main outcome is to set up and validate a reliable and reproducible automated method using preoperative radiological imaging to measure the TSBL in patients candidates for laparoscopic bariatric/metabolic surgery. The results of AI measurement will be compared with those of laparoscopic measurement to examine the level of concordance

Countries

Italy

Contacts

Primary ContactNiccolò Petrucciani, MD
niccolo.petrucciani@uniroma1.it3496311476

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026