Skip to content

Reducing Vertigo Associated With MRI Machines

Reducing Vertigo Associated With MRI Machines

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06062368
Enrollment
100
Registered
2023-10-02
Start date
2024-01-15
Completion date
2028-01-01
Last updated
2025-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dizziness, Vertigo

Keywords

MRI, 7 Tesla, Magnetic Vestibular Stimulation

Brief summary

Vertigo, dizziness, and imbalance are commonly reported by patients and technologists when near high-field strength magnets (\>4 Tesla, T) used for magnetic resonance imaging (MRI) (1-5) Prior research from the investigators has established that the mechanism is likely a Lorentz force occurring in the inner ear, as a result of interactions with normal electrical currents in the inner ear and the strong static magnetic field of the MRI machine. The investigators have recently developed preliminary data to suggest that slower rates of entry into the magnetic field can greatly attenuate the sensations of vertigo. The explanation for this is that the rates of vestibular adaptation exceed that of the stimulus, allowed a reduction or elimination of the symptoms of vertigo. The aim of this study is to recruit individuals who are already getting an MRI scan as part of other research studies to randomize the rate of entry into and exit from the static magnetic field (i.e., before and after imaging is performed). The usual rate of entry is 20 seconds. This will be increased to one, two or three minutes. The investigators will record subjective sensations of dizziness and vertigo associated with the entry into the MRI.

Detailed description

Vertigo and nystagmus are commonly reported in 7 Tesla MRI machines, in upwards of 2/3 of individuals. Magnetic vestibular stimulation (MVS) of the inner ear explains these symptoms. In the normal state, the inner ear has constant electric current flowing from the dark cells to the hair cells of the utricular macula through the potassium enriched endolymph. This electric current drives the utricle's exquisitely sensitive response to linear accelerations. Near the utricular macula are the cupulae of the lateral and superior semicircular canals (SCCs), which are exquisitely sensitive to angular accelerations. Inside an MRI scanner, the electric current entering the utricular macula in each ear interacts with the MRI static magnetic field to create a Lorentz (magneto-hydrodynamic (MHD) force in the endolymph that pushes on the cupulae of the nearby lateral and superior semicircular canals. The force scales linearly with magnetic field strength. Thus, when a human with an intact vestibular system lies in a 7 T MRI magnet, the Lorenz force causes the endolymph to push on the cupulae, changing activity of the angular vestibulo-ocular reflex (VOR) pathway, generating both a transient sensation of motion and a sustained beating of the eyes (nystagmus), with alternating slow phases from the VOR and quick phases that reset the position of the eye. Adult individuals that are undergoing a 7 Tesla MRI as part of other research protocols at Kennedy-Krieger Kirby Institute, will be recruited. The usual entry into the magnetic field is a button that is pressed, that enters the magnetic field over 20 seconds, and exits the magnetic field over 20 seconds. Each participant will be randomized to one of four groups: 1) entering/exiting at the usual 20 seconds, 2) entering/exiting over 1 minute, 3) entering/exiting over 2 minutes, or 4) entering/exiting over 3 minutes. Participants will be asked to close the eyes during entry and exit. The onset of vertigo and description of the sensation will be recorded. At 15 second intervals, the participants will be asked to rate vertigo on a scale from 0 (no vertigo) to 3 (severe vertigo). The end time of vertigo sensations will also be recorded. The same procedure will be completed when exiting the MRI scan.

Interventions

BEHAVIORALRate of Entry

The participant will enter and exit the MRI scan at a slower rate than the manufacturer entry and exit.

Sponsors

National Institute on Deafness and Other Communication Disorders (NIDCD)
CollaboratorNIH
Johns Hopkins University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Subject)

Masking description

The participant will be unaware of the group they are participating in.

Intervention model description

Individuals will be randomized to one of four groups, each with a different rate of entry into and exit out of the 7 Tesla MRI machine.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Participants who will be undergoing an MRI scan at a 7 Tesla MRI.

Exclusion criteria

*

Design outcomes

Primary

MeasureTime frameDescription
Prevalence of vertigo symptomsDuring MRI up to 6 minutesParticipants will report the presence and intensity of their vertigo. The presence or absence of vertigo for each group will be the primary outcome.

Secondary

MeasureTime frameDescription
Intensity of VertigoDuring MRI up to 6 minutesParticipants will report the intensity of their vertigo symptoms when entering and exiting the MRI scan on a scale from 0 (no vertigo)-3 (severe vertigo) at 15 second intervals. 0=no vertigo, 1=mild vertigo, 2=moderate vertigo, 3=severe vertigo
Duration (seconds) of VertigoDuring MRI up to 6 minutesParticipants will report the onset and cessation of their vertigo symptoms when entering and exiting the MRI scanner. The duration will be calculated in seconds.

Countries

United States

Contacts

Primary ContactBryan K Ward, MD
bryan.k.ward@gmail.com443-997-6467
Backup ContactAdrian Paez, BA
paez@kennedykrieger.org443-923-9200

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026