Skip to content

Evaluation of Different Lenticule Diameters in Myopic Astigmatism Correction With SMILE Procedures

Evaluation of Different Lenticule Diameters in Myopic Astigmatism Correction With SMILE Procedures

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06062004
Enrollment
50
Registered
2023-10-02
Start date
2018-11-27
Completion date
2024-04-30
Last updated
2023-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopic Astigmatism, Refractive Errors

Keywords

SMILE, Myopia, Refractive Surgery, Astigmatism, Small Incision Lenticule Extraction

Brief summary

Small incision lenticule extraction (SMILE) is a refractive intrastromal procedure for myopia and myopic astigmatism correction. Most of the studies evaluating astigmatic correction by SMILE reported astigmatic under-correction, especially in high degrees of astigmatism. This under-correction could be due to: first, the active eye tracker or the iris registration is not yet available to overcome the cyclotorsion that occurred during the treatment with the VisuMax femtosecond laser system (Carl Zeiss Meditec, Jena, Germany) which could be overcome by manual compensation technique, especially in higher degrees of cylinders (\> 1.5 diopters (D)). Second, in patients with small lenticule diameters, the more abrupt change in thickness at the edge of the treated area could induce more stromal and epithelial healing in this area. Thus, the astigmatic correction would be less effective with small than large lenticule diameters for similar high preoperative astigmatism. This study assessed the outcome of using a 0.5 millimeter (mm) larger lenticule diameter in the fellow eyes of myopic astigmatic correction SMILE participants. This assessment included the safety and effectiveness indices, the refractive and visual outcomes, the contrast sensitivity, and some morphological outcomes such as corneal curvature and epithelial and corneal thickness.

Detailed description

Study Title: Evaluation of different lenticule diameters in myopic astigmatic correction with SMILE procedures Primary Investigator: Dr. Ahmed Sedky (Eye Subspecialty Center, Cairo, Egypt, 18 Elkhalifa Elmamoun Street, Heliopolis, Cairo, Egypt) Co-Investigators: Sherine S Wahba, Maged M Roshdy, Nermeen A Refaat Study Objectives Primary Objective: To study the effect of changing the lenticule diameter on the safety and effectiveness of myopic astigmatism correction with the SMILE procedure. Secondary Objective: To compare other outcomes such as visual outcomes including immediate visual acuity, contrast sensitivity, and epithelial remodeling. Participants and Methods: Study Setting: Eye Subspecialty Center, Cairo, Egypt, 18 Elkhalifa Elmamoun Street, Heliopolis, Cairo, Egypt and Al Watany Eye Hospital, Althawra Street, Cairo, Egypt Study design: Hospital-based, comparative, prospective, interventional contralateral eye study Sample size and randomization: 50 participants fulfilling the inclusion criteria will be enrolled in the study. Their right eyes undergo SMILE procedure using the standard 6.5 mm lenticule diameter and their left eyes undergo SMILE procedure but using a larger lenticule diameter of 7.0 mm. Ethical issues: Institutional ethics committee approval will be obtained. Participants' informed consent will be taken and the procedure explained to them in their own language. Any intra-operative or post-operative complications occurring in either group will be documented and duly informed to the ethics committee Preoperative evaluation: 1. Anterior and posterior segment clinical examination 2. Uncorrected distance visual acuity (UDVA) in decimal and logMAR units 3. Corrected distance visual acuity (CDVA) in decimal and logMAR units 4. Corneal tomography using the Pentacam high resolution (HR) (Oculus Optikgeräte, Wetzlar, Germany) including the flattest and steepest meridians (in keratometric diopters (D), the axes (in degrees) 5. Contrast sensitivity (CSV1000E test (Good-Lite, Elgin, Illinois, USA)) in 4 different special frequencies 6. Anterior segment Optical Coherence Tomography (Cirrus, Carl Zeiss Meditec, Jena, Germany) measurement of total corneal and epithelial thickness in µm Study duration: 3 months for recruitment of the patients. Surgical technique: All surgeries will be performed under topical anesthesia using the VisuMax femtosecond laser with the following parameters: Cap thickness of 120 μm Cap diameter is either 7.5 mm for lenticule diameter 6.5 mm or 8.0 mm for lenticule diameter 7.0 mm. Cap side cut angle 70° 3 mm incision positioned at 100° and angled at 45° A transition zone of 0.1 mm and clearance of 0.5 mm Lenticule side cut angle of 90° and edge lenticule thickness of 15 μm Directly preoperative, the limbus will be marked in the 0° to 180° axis with a marker pen in the upright head position on the slit lamp. Then, the patient will be positioned under the VisuMax femtosecond laser and instructed to look into the green flashing fixation light. Once proper centration is achieved, the eye will be docked to the patient interface and suction will be applied. Manual compensation will be done by gently rotating the contact glass to align the horizontal marks on the eye to the 0° to 180° axis. Once both are aligned, the laser process will be done to create the refractive lenticule followed by its dissection and washing of the interface by a balanced salt solution. Medication: will be the standard treatment; topical steroids and antibiotics 4 times per day for 10 days and tear substitutes 4 times daily for one to two months. Postoperative evaluation: Follow-up of the subjects will be done in 1 day, 1 week, 3 months, and 6 months. Data will be collected for analysis starting from 1 week, including: 1. Uncorrected distance visual acuity (UDVA) in decimal and logMAR units 2. Corrected distance visual acuity (CDVA) in decimal and logMAR units 3. Corneal tomography using the Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) including the flattest and steepest meridians (in diopters (D), the axes (in degree) 4. Contrast sensitivity (CSV1000E test (Good-Lite, Elgin, IL, USA)) in 4 different special frequencies 5. Anterior segment Optical Coherence Tomography (Cirrus HD-OCT, Carl Zeiss Meditec, Jena, Germany) measurement of total corneal and epithelial thickness in µm.

Interventions

All surgeries will be performed under topical anesthesia using the VisuMax femtosecond laser with the following parameters: * Cap thickness of 120 μm * Cap diameter of 1 mm larger than the lenticule diameter * Cap side cut angle 70° * 3 mm incision positioned at 100° and angled at 45° * Transition zone of 0.1 mm and clearance of 0.5 mm * Lenticule side cut angle of 90° and edge lenticule thickness of 15 μm

Sponsors

Al Watany Eye Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Hospital-based, comparative, prospective, interventional contralateral eye study

Eligibility

Sex/Gender
ALL
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Age groups between 18 and 50 years * Myopic astigmatism with up to -10.00 D spherical equivalent (SE) and a minimum astigmatism of -1.0 D and a maximum of -5 D. The astigmatism will be divided into low astigmatism (\<0.75 D), moderate astigmatism (1.5- 3 D) and high astigmatism (\>3 D). * Corrected distance visual acuity (CDVA) of 0.7 or better (decimal)

Exclusion criteria

* Thin corneas (\< 490 μm) * Proven or suspicious cases of corneal ectatic conditions by corneal tomography * Previous ocular surgeries * Patients taking systemic steroids, immunosuppressants, oral contraceptives, or antidepressants * Pregnant females * Corneal scars or any ocular pathology likely to affect visual outcomes

Design outcomes

Primary

MeasureTime frameDescription
The safety index of using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatismup to 6 monthsThe safety index (unitless parameter) is calculated as postoperative CDVA/ preoperative CDVA (both in decimal units).
The efficacy index of using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatismup to 6 monthsThe efficacy index (unitless parameter) is calculated as postoperative UDVA/ preoperative CDVA (both in decimal units).

Secondary

MeasureTime frameDescription
Contrast sensitivity outcomes of using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.up to 6 monthsTo compare postoperative photopic and mesopic contrast sensitivity (in log unit) at 3, 6, 12, and 18 cycles per degree of SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism. This will be done using the CSV1000E device (Good-Lite, Elgin, IL, USA)
Refractive outcomes of using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.up to 6 monthsTo compare subjective refractive outcomes including spherical equivalent and residual astigmatism (in diopters) of SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.
Corneal structural changes after SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.up to 6 monthsTo compare postoperative and central corneal and epithelial thickness (in micrometers) and standard deviation of epithelial thickness in different locations (in micrometers) after SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism. This will be done using the anterior segment OCT (Cirrus HD-OCT, Carl Zeiss Meditec, Jena, Germany)
Corneal curvature changes after SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.up to 6 monthsTo compare postoperative corneal curvature in flattest and steepest meridia (in keratometric diopters) after SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism. This will be done using the Pentacam high resolution (HR) (Oculus Optikgeräte, Wetzlar, Germany).
Visual acuity outcomes of using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.up to 6 monthsTo compare postoperative UDVA and CDVA (in logMAR) of SMILE procedure using 7 and 6.5 mm lenticule diameters SMILE to treat myopic astigmatism.

Countries

Egypt

Contacts

Primary ContactSherine Shafik, PhD
s_shafik@hotmail.com00201222421896

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026