Skip to content

Use of 4D-ICE in Conjunction With TEE for Left Atrial Appendage Closure

Use of 4D Intracardiac Echocardiography (4D-ICE) in Conjunction With Transesophageal Echocardiography (TEE) for Left Atrial Appendage Closure (LAAC)

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06061757
Enrollment
52
Registered
2023-09-29
Start date
2023-05-10
Completion date
2025-12-31
Last updated
2025-08-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation, Stroke

Brief summary

This is a prospective, single center, non-randomized study with two parallel arms intended to study if 4D Intracardiac echocardiography (4D-ICE) (Nuvision, Nuvera TM) will provide better visualization of the anatomical landmarks from the larger imaging volume and provide optimal intra procedural guidance similar to Transesophageal echocardiography (TEE) (GE 6VT-D ULTRASOUND TRANSDUCER) for Left atrial appendage closure (LAAC). The study will enroll approximately 52 subjects and will be followed through 12 months.

Detailed description

Standard intraprocedural guidance for transcatheter left atrial appendage closure (LAAC) employs a multi-modality integrated approach combining fluoroscopy for guiding the delivery system, and transesophageal echocardiography (TEE) for intracardiac characterization to guide device selection and monitor procedural complications. Successful implantation of the device is confirmed with contrast-enhanced fluoroscopy and color doppler flow imaging on TEE. TEE is the current gold standard for procedural guidance but requires general anesthesia (GA) to avoid patient motion and discomfort during the procedure. General anesthesia, however, is associated with pulmonary complications and patient discomfort due to endotracheal intubation. Intraprocedural LAAC guidance under local anesthesia or conscious sedation might help mitigate these GA-related disadvantages and has motivated multiple clinical studies, establishing intracardiac echocardiography (ICE) as a safe and feasible alternative to TEE. The new generation of NuVision ICE catheter offers a larger imaging volume of 90° x 90° with multiplanar reformatted (MPR) echo views for better visualization of anatomical landmarks and procedural guidance and aid in sizing of the device. This has a potential to improve outcomes and reduce procedure times while lowering healthcare costs. In this study, Role of NuVision Intracardiac Echocardiographic (ICE) catheter with Tranesopheal echocardiography (TEE) in predicting intra-procedural outcomes and success of implantation in patients undergoing left atrial appendage occlusion will be assessed.

Interventions

DEVICEImaging guidance with TEE and ICE for Left atrial appendage closure

The occluder size for both LAAC devices will be selected based on the maximal diameter of the LAA orifice following the manufacturer guidelines and using the maximal length of the LAA measured on Echocardiogram. Intraprocedural measurements of the LAA width and depth were acquired on both ICE and TEE per protocol. Both ICE and TEE will be used to assess for any procedural complications prior to insertion of the device delivery sheath.

Sponsors

Kansas City Heart Rhythm Research Foundation
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Male/Females * Age:18-80 years * History of Atrial Fibrillation/Atrial flutter * Will have endocardial Left Atrial Appendage Closure (LAAC) with an Amplatzer Amulet or WATCHMAN FLX device

Exclusion criteria

* Inability or unwillingness of an individual to give written informed consent * Patient not following with our practice after the procedure * Complex anatomy for endocardial LAAC * Thrombus in LAA * Patients with pericardial effusion in pre-op TEE/CCTA * Patients currently pregnant (Serum beta HCG completed when labs obtained for the procedure are completed)

Design outcomes

Primary

MeasureTime frameDescription
Success of Implantation of Left Atrial Appendage Closure (LAAC) device1 DaySuccess of Implantation of Amulet or Watchman FLX device

Secondary

MeasureTime frameDescription
Intraprocedural measurements1 DayTranseptal access view, LAA thrombus, Stability of the device, Peri-device leaks, Device Repositioning, Clarity of mitral valve or pulmonary vein impingement will be noted as Yes/No from Echocardiogram
Intraprocedural measurements - LAA device size1 DayLAA device size will be measured based on the LAA size
Location of the leaks1 DayLocation of the leaks will be identified

Other

MeasureTime frameDescription
Post Procedural Outcomes45 Days, 6 Months and 12 MonthsPresence of any Peri-device leaks (PDL), Device Related Thrombus (DRTs), Micro migration and device tilt will be noted.
Post Procedural Outcomes - Size of the leaks45 Days, 6 Months and 12 MonthsLeaks if any, leaks size will be measured

Countries

United States

Contacts

Primary ContactDonita Atkins
datkins@kchrf.com816-651-1969

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026