Arthritis Knee, Gait Biomechanics, Muscle Strength, Osteoarthritis, Total Knee Arthroplasty
Conditions
Brief summary
Total Knee Arthroplasty (TKA) is actually the most effective treatment option for patients with end-stage osteoarthritis (OA). However, nearly 20% of patients who underwent TKA remain unsatisfied with their clinical outcome. Investigating modifiable factors that limit knee functioning following TKA we may notice the significance of lower limb muscles strength. Gait pattern is also affected by OA, as arthritic knee joint cannot provide proper range of motion (ROM) and stability.Therefore any deviation in biomechanics should be noticed and analyzed. After TKA patients' physical function may change, but the study should be conducted to prove whether it improves or not. Patient-reported outcome defined by OKS (Oxford Knee Score) and FJS (Forgotten Joint Score) questionnaires will be evaluated.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* III° or IV° grade knee osteoarthritis * Age over 50 * Patients with signed consent
Exclusion criteria
* Undergone total hip replacement * Previous femur fracture in anamnesis * Undergone corrective osteotomy * Active/ Chronic neoplastic disease * Significant deformation of lower limb axis * Mental disorders * Muscular disorders
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Physical function assessment based on standardized test | 6 months | Analysis of pre- and postoperative physical function on the basis of Up and Go test. |
| Gait biomechanics analysis - phases of gait | 6 months | Analysis of pre- and postoperative parameters of gait pattern and biomechanics with a use of Baiobit device (wearable motion analysis system). Subjected to the analysis will be the swing and the stance phase of gait (% of the gait cycle). |
| Gait biomechanics analysis - step duration | 6 months | Analysis of pre- and postoperative parameters of gait pattern and biomechanics with a use of Baiobit device (wearable motion analysis system). Subjected to the analysis will be the duration of left and right step (in seconds). |
| Muscle strength measurement with a use of dynamometer | 6 months | Analysis of pre- and postoperative strength of lower limb muscles. Assessment of force \[N\] generated by knee flexors, knee extensors, hip adductors and hip abductors with a use of a hand-held dynamometer. |
| Gait biomechanics analysis - step length | 6 months | Analysis of pre- and postoperative parameters of gait pattern and biomechanics with a use of Baiobit device (wearable motion analysis system). Subjected to the analysis will be the step length (in meters). |
| Gait biomechanics analysis - gait speed | 6 months | Analysis of pre- and postoperative parameters of gait pattern and biomechanics with a use of Baiobit device (wearable motion analysis system). Subjected to the analysis will be the gait speed (metre per second). |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Patient-reported outcome - Forgotten Joint Score | 6 months | Pre- and postoperative evaluation of Forgotten Joint Score. The questionnaire is based on 12 questions. Total score ranges from 0 to 100. Higher score on the questionnaire, means better results were obtained. |
| Patient-reported outcome - Oxford Knee Score | 6 months | Pre- and postoperative evaluation of Oxford Knee Score. Patients will be asked 12 closed-end questions. 5 possible answers to choose. The scoring system is from 0 to 4 for each answer. Total score ranges from 0 to 48, where 0 is the poorest outcome, and 48 is the best one. |
Countries
Poland