Ridge Augmentation
Conditions
Keywords
Peridontal bone defect, Guided Bone Regeneration (GBR), Ridge augmentation, Peridontal bone defect requiring GBR ridge augmentation, Guided Tissue Regeneration (GTR)
Brief summary
The NOVAMag® membrane is a medical device approved in the EU, and is a completely resorbable and biodegradable metal membrane. This medical device is used in the treatment of bone defects in the oral cavity. The membrane ensures sufficient stability of the bone augmentation material and provides a barrier to the soft tissue. This enables new bone to form in the defect space and for the subsequent placement of dental implants. In this clinical trial, the NOVAMag® membrane is compared with the Jason® collagen membrane, another medical device for supporting bone regeneration, with the aim of demonstrating the non-inferiority in terms of radiographically measured volumetric bone gain of the NOVAMag® membrane to the comparator membrane.
Detailed description
GBR is a well-established surgical procedure based on the use of tissue barriers to separate the void of hard tissue defects from overlying connective tissues, thus preventing the ingrowth of soft tissue into the defect site resulting in improved bone regeneration. GBR is used both with and without different bone graft materials, such as allografts, xenografts and synthetic substitute materials, which have shown comparable results to those obtained with autologous bone in localized horizontal defects. The barrier membranes used in GBR can be produced from animal (bovine, porcine), human (allogenic) and synthetic biomaterials. Due to their origin, composition and manufacturing process, each biomaterial performs differently in the human body, with their own associated advantages and disadvantages. Non-resorbable membranes (primarily made from PTFE \[polytetrafluoroethylene\] and titanium\] can offer mechanical reinforcement to protect the defect void, as well as maintain a continuous barrier function until they are removed. The main disadvantage of these membranes is the necessity of a second surgical procedure for their removal. In response to this disadvantage, resorbable membranes have been developed with porcine collagen membranes considering the standard product for use in GBR. These collagen membranes produce excellent biocompatible results, but they lack mechanical stability, especially for use in larger augmentation sites. To address the aforementioned issues of both the resorbable and non-resorbable membranes, botiss biomaterials GmbH has developed the NOVAMag® membrane, which has recently received CE approval. The NOVAMag® membrane is a resorbable, biodegradable magnesium membrane. The material properties of the pure magnesium membrane culminate into a design that has a mechanical stability not provided by other resorbable membranes. Despite being resorbable, the membrane maintains a separation of the soft and hard tissues until the bony defect has been repaired (data on file at botiss). The ability of membranes to resist collapse into the defect void and maintain space for the ingrowth of new bone is viewed as an important aspect for producing a successful regenerative outcome. This is most easily achieved by using a strong material that can resist the external pressures of the overlying soft tissue and the forces experienced during function. The risk of collapse tends to be higher for resorbable membranes due to inferior mechanical properties. Mechanical testing performed by botiss have proven that the magnesium membrane is self-supporting and substantially stronger than other resorbable collagen membranes. Therefore, the risk of collapse into the defect void, as reported for collagen membranes, could potentially be prevented by using the NOVAMag® membrane. The aim of this randomized clinical study is to compare a bioresorbable magnesium NOVAMag® membrane with the collagen Jason® membrane in patients requiring guided bone regeneration.
Interventions
After the application of local anesthesia, an incision of the mucosa will be performed and the flap will be elevated. The flap closure line should not be directly over the defect, but away from the defect site to prevent wound dehiscence. The bony defect will be thoroughly cleaned and, in some cases, activated by drilling small holes in the cortical bone to increase blood flow into the bone graft. Bone substitute will be inserted, the membrane will be adapted and fixed, and the flap will be sutured
After a healing period of 6 months, at the implantation site, a biopsy is taken from the site of dental implant insertion for further analysis of bone regeneration
Sponsors
Study design
Eligibility
Inclusion criteria
Eligible are healthy patients that have the need for at least one dental implant. Specific inclusion criteria are: Inclusion Criteria: 1. Obtained informed consent from the patient, patients voluntarily signing the informed consent form before study related actions including patient's acceptance of the scheduled program of clinical and radiographic analysis 2. The patient shall be at least 18 years of age, male or female and have passed cessation of growth 3. Patients asking for more than one dental implant and presenting one site with a healed site (class h1i, h2i; h3i, v1i, c1i, h1e, h2e, h3e, Cologne Classification of Alveolar Ridge Defects (CCARD) requiring a GBR procedure prior to implant placement. 4. The teeth at the implant site must have been extracted or lost at least 8 weeks before the date of bone augmentation (volumetrically healed site)
Exclusion criteria
Systemic
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Relative difference in bone volume between the groups at the augmentation site after GBR measured radiographically | Pre-treatment visit (T-1) to the clinical check up visit after five and a half months (T4) | Mean volumetric increase in % |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Histomorphometric assessment of the differences in bone volume between the groups | T5: after a healing period of 6 months | After 6 months a biopsy is taken from the site of dental implant insertion for further analysis. Undecalcified thin ground sections will be prepared. The following variables will be determined: * Bone volume per tissue volume in % (BV/TV) * New bone volume per tissue volume in % (nBV/TV) * Old bone volume per tissue volume in % (oBV/TV) * Total graft volume per tissue volume in % (GV/TV) |
| Evaluation of between group differences for the presence of side effects | At each follow-up visit: T1 (after 7-10 days), T2 (after 14 ± 3 days), T3 (after 1 month ± 4 days) and T5 (after 6 months ± 2 weeks) | Presence or absence of side effects will be evaluated by the investigator during the scheduled follow-up appointments. Side effects to be assessed are: * Gas formation * Prickly feeling at surgery site (dysesthesia) * Redness/swelling * Bleeding * Wound dehiscence * Infection * Abscess/pus formation |
| Evaluation of between group differences for pain | At each follow-up visit: T1 (after 7-10 days), T2 (after 14 ± 3 days), T3 (after 1 month ± 4 days) and T5 (after 6 months ± 2 weeks) | Pain will be self-assessed by the patients via a numerical rating scale (NRS) during the scheduled follow-up appointments. The scale has a measurement range of 0 to 10 (each inclusive). The higher the value, the more pain the patients experience. |
| Safety outcome measures | At T-1 (pre-treatment), T0 (= day 0 = day of surgery), T1 (after 7-10 days), T2 (after 14 ± 3 days), T3 (after 1 month ± 4 days), T5 (after 6 months ± 2 weeks), T6 (7-10 days after T5) | The following Safety Endpoints will be evaluated by group at each visit: * Adverse events (AE) and Serious adverse events (SAEs) * Device related adverse events (adverse device effects (ADE) * Seriousness of device related adverse events (serious adverse device effect (SADE) * Device deficiency (DD) |
| Usability of the NOVAMag® membrane and its accessory products | At the end of the visit T0 [= day 0 = directly after GBR surgery] | By completing a survey regarding the handling of the NOVAMag® membrane and its accessories by the investigator the usability will be evaluated. |
| Radiographic outcome measure: Changes in horizontal bone dimensions over time in mm. | At T-1 (pre-treatment) and T4 (5 and a half months ± 2 weeks) | At T-1 and T4 a Cone Beam Computed Tomography (CBCT) is taken. CBCTs are compared and horizontal bone dimensions are measured at 2 mm, 4 mm, and 6 mm from the crest. |
| Radiographic outcome measure: Changes in vertical bone dimensions over time in mm. | At T-1 (pre-treatment) and T4 (5 and a half months ± 2 weeks) | At T-1 and T4 a Cone Beam Computed Tomography (CBCT) is taken. CBCTs are compared and vertical bone dimensions are measured in mm. |
| Radiographic outcome measure: Bone quality assessment | T4 (after 5 and a half months ± 2 weeks) | Bone quality assessment by evaluation of presence or absence of gas cavities by analysis of CBCT images after 6 months (only presence is reported from X-rays) |
Countries
Austria, Denmark, Italy
Contacts
University of Vienna, Department of Oral Surgery, Austria