Skip to content

Standard Ultrasound Guidance vs. New Needle-steering Device in Subclavian Venous Catheterization

Ultrasound-guided Subclavian Venous Catheterization. A Randomized, Single-blind, Controlled Superiority Trial Comparing Standard Ultrasound Guidance and a New Needle-steering Device

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06050902
Acronym
NEEDLEVISIO2
Enrollment
124
Registered
2023-09-22
Start date
2024-01-16
Completion date
2025-12-26
Last updated
2026-07-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Central Venous Catheterization, Ultrasound Guidance

Keywords

subclavian vein, needle-steering device

Brief summary

Up to two-thirds of intensive care unit patients require central venous catheterization for which ultrasound-guided placement is now recommended. In this context, the team performed a prospective randomized simulation trial on a mannequin ("reduced torso model"), to compare the standard ultrasound guidance technique with an ultrasound-guided technique assisted by a new needle-steering device. The preliminary results show a statistically significant improvement in subclavian venipuncture (shorter success time, fewer multiple skin punctures, fewer punctures of the posterior wall of the subclavian vein and needle redirection, greater comfort) and argue for a clinical trial to test the performance of this new device in situation with intensive care unit patients. The hypothesis is that the needle-steering device will result in a better success rate of subclavian venous cannulation, at first puncture, compared with the conventional ultrasound-guided technique.

Detailed description

Central venous catheterization is required in up to two-thirds of intensive care unit patients. Ultrasound-guided placement is now recommended over the "blind" technique to decrease the risk of mechanical complications and duration of the procedure. Although the subclavian site is recommended as first-line because of a lower risk of catheter-related infection and thrombosis (than with internal jugular and femoral sites), this approach is underused (\< 20% of regular users). There is also a very low use of ultrasound guidance for subclavian catheterization (\< 30% of cases), due to technical difficulties such as more complex visualization of the needle. New magnetic devices theoretically allow better visualization of the needle, a higher success rate and a lower complication rate. In this context, the team performed a prospective randomized simulation trial on a phantom ("reduced torso model"), comparing the standard ultrasound guidance technique with an ultrasound-guided technique assisted by a new needle-steering device in subclavian central venous catheterization (study in progress). The results of this study show a statistically significant improvement in subclavian venipuncture (shorter success time, fewer multiple skin punctures, fewer punctures of the posterior wall of the subclavian vein and needle redirection, greater comfort). These preliminary results argue for a clinical trial of the practical performance of this new device in intensive care unit patients. The hypothesis is that the needle-steering device will result in a higher success rate of subclavian venous cannulation at first puncture compared with the conventional ultrasound guidance technique.

Interventions

DEVICESubclavian venipuncture for catheter placement using the needle-steering device

1. Navigation software is implemented in an ultrasound machine. 2. A linear ultrasound probe (similar in appearance to a standard ultrasound probe) is used 3. Magnetization of the puncture needle after short introduction of the needle in a dedicated device. 4. Real time needle guidance on the ultrasound screen during the puncture.

Sponsors

Centre Hospitalier Universitaire de Nīmes
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
SINGLE (Subject)

Masking description

The patient will be blinded to his or her assignment group. The primary endpoint and secondary endpoints A, D, G, H, will be collected by an assessor independent from the operator, during the central venous catheterization procedure. This assessor will not be blinded to the technique used.

Intervention model description

A randomized, patient- and evaluator-blinded, controlled superiority trial comparing standard ultrasound guidance and a new needle-steering device.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Any resuscitation patient requiring subclavian venous catheterization. * Patients or representatives must have given free, informed consent and signed the consent form or patient included in an emergency situation * Patients must be affiliated to/or beneficiary of a health insurance scheme. * All patients must be adults (≥18 years of age).

Exclusion criteria

* Moribund patients * Patients with severe primary or secondary hemostasis disorders (Pq \< 50 G/L or TP \< 30%, or INR \> 2). * Patients with a PaO2/FiO2 ratio \< 100 mmHg in mechanically ventilated patients (invasive or non-invasive ventilation). * Patients with a precarious or unstable respiratory status and significant risk of barotrauma * Patients for whom it is difficult to visualize the subclavian veins bilaterally (left and right) during ultrasound pre-screening * Patients with a malformation/deformity of the subclavian region (congenital or acquired: history of surgery/cervical trauma) * Body mass index \< 15 kg/m² ou \> 40 kg/m² * Local infection at the puncture site * Thrombosis of the subclavian or axillary vein * Patients participating in a category 1 defined RIPH involving subclavian central venous line placement. * Patients under court protection, guardianship or curatorship. * Pregnant, parturient or breastfeeding women.

Design outcomes

Primary

MeasureTime frameDescription
Successful catheter insertion at first skin puncture: Control groupDay 0The main objective is to compare the success rate of subclavian venous cannulation at first puncture between the conventional ultrasound guidance technique and ultrasound guidance assisted by a needle-steering device. Successful subclavian venous cannulation (success is defined as catheter insertion at first skin puncture). YES/NO
Successful catheter insertion at first skin puncture: Experimental groupDay 0The main objective is to compare the success rate of subclavian venous cannulation at first puncture between the conventional ultrasound guidance technique and ultrasound guidance assisted by a needle-steering device. Successful subclavian venous cannulation (success is defined as catheter insertion at first skin puncture). YES/NO

Secondary

MeasureTime frameDescription
A. Number of skin punctures required before successful central venous catheterism: Control groupDay 0Median number of skin punctures required before successful central venous catheterism. Success is defined as catheter insertion.
A. Number of skin punctures required before successful central venous catheterism: Experimental groupDay 0Median number of skin punctures required before successful central venous catheterism. Success is defined as catheter insertion.
B. Complication rate. All causes, composite score: Control groupDay 0Onset of at least one complication due to venous puncture. Complications including pneumothorax, arterial puncture, hematoma, malpositioning or puncture failure will all be recorded.
B. Complication rate. All causes, composite score: Experimental groupDay 0Onset of at least one complication due to venous puncture. Complications including pneumothorax, arterial puncture, hematoma, malpositioning or puncture failure will all be recorded.
C. Pneumothorax within 24 hours of venous puncture: Control groupHour 24Data collection using a standardized online electronic Case Report Form. Clinical history + frontal chest X-rays taken within one hour of puncture AND at H12-24 +/- ultrasound or computed tomography scan according to clinical or diagnostic doubt (examinations carried out at the discretion of the physicians). The number and percentage of patients with pneumothorax will be recorded.
C bis. Drainage required for pneumothorax within 24 hours of venous puncture: Control groupHour 24Data collection using a standardized online electronic Case Report Form. YES/NO
C. Pneumothorax within 24 hours of venous puncture: Experimental groupHour 24Data collection using a standardized online electronic Case Report Form Clinical history + frontal chest X-rays taken within one hour of puncture AND at 12-24 hours +/- ultrasound or computed tomography scan according to clinical or diagnostic doubt (examinations carried out at the discretion of the physicians). The number and percentage of patients with pneumothorax will be recorded.
C bis. Drainage required for pneumothorax within 24 hours of venous puncture: Experimental groupHour 24Data collection using a standardized online electronic Case Report Form YES/NO
D. Arterial puncture within 24 hours of venous puncture: Control groupDay 0YES / NO Data collection using a standardized online electronic Case Report Form. Any arterial punctures during the procedure will be recorded in numbers and percentages by an independent investigator, present during the procedure and therefore aware of technique used.
D. Arterial puncture within 24 hours of venous puncture: Experimental groupDay 0YES / NO Data collection using a standardized online electronic Case Report Form. Any arterial punctures during the procedure will be recorded in numbers and percentages by an independent investigator, present during the procedure and therefore aware of technique used.
E. Hematoma or hemorrhage Grade 3 or over within 24 hours of venous puncture: Control groupHour 24YES / NO. Data collection using a standardized online electronic Case Report Form. Clinical history + frontal chest X-rays taken within one hour of puncture AND at H12-24 +/- ultrasound or CT scan according to clinical point of call or diagnostic doubt (examinations carried out according to the choice of the department's physicians). Within 24 hours, occurrence of hematoma or hemorrhage grade ≥ 3 (specify whether a therapeutic intervention is required - according to the definition below - or transfusion for intrathoracic bleeding). The occurrence of grade ≥ 3 hematoma or hemorrhage will be established according to the definition of "Common Terminology Criteria for Adverse Events (CTCAE) v5.0": indication for transfusion or invasive intervention (grade 3), need for urgent intervention or alteration of vital prognosis (grade 4), or death (grade 5).
E. Hematoma or hemorrhage Grade 3 or over within 24 hours of venous puncture: Experimental groupHour 24YES / NO. Data collection using a standardized online electronic Case Report Form . Clinical history + frontal chest X-rays taken within one hour of puncture AND at H12-24 +/- ultrasound or CT scan according to clinical point of call or diagnostic doubt (examinations carried out according to the choice of the department's physicians). Within 24 hours, occurrence of hematoma or hemorrhage grade ≥ 3 (specify whether a therapeutic intervention is required - according to the definition below - or transfusion for intrathoracic bleeding). The occurrence of grade ≥ 3 hematoma or hemorrhage will be established according to the definition of "Common Terminology Criteria for Adverse Events (CTCAE) v5.0": indication for transfusion or invasive intervention (grade 3), need for urgent intervention or alteration of vital prognosis (grade 4), or death (grade 5).
F. Malpositioned catheter seen on the X-ray within 1 hour of venous puncture: Control groupHour 24YES / NO. Data collection using a standardized online electronic Case Report Form . Front thoracic radiograph (systematically within one hour of puncture) puncture): "Sweet Spot" technique (approximation of the atriocaval junction, a rectangle in which the position of the lower end of the central venous line: between the lower third of the superior vena cava and the inferior lower edge of the right atrium (located by the cardiophrenic angle). Malpositioning will be recorded as numbers and percentages.
F. Malpositioned catheter seen on the X-ray within 1 hour of venous puncture: Experimental groupHour 24YES / NO. Data collection using a standardized online electronic Case Report Form. Front thoracic radiograph (systematically within one hour of puncture) puncture): "Sweet Spot" technique (approximation of the atriocaval junction, a rectangle in which the position of the lower end of the central venous line: between the lower third of the superior vena cava and the inferior lower edge of the right atrium (located by the cardiophrenic angle). Malpositioning will be recorded as numbers and percentages.
G. Time taken from first skin puncture to successful catheter insertion: Control groupDay 0In seconds
G. Time taken from first skin puncture to successful catheter insertion: Experimental groupDay 0In seconds
H. Failure rate: Control groupDay 0Percentage of failures. After three failed punctures, the technique is considered as a failure. Data collection using a standardized online electronic Case Report Form. The number of skin punctures will be counted. The criterion "failure" will be retained after 3 unsuccessful skin punctures. This requires a change of insertion site and withdrawal from the study. The other complication criteria mentioned above will still be recorded and analyzed but the time will not be collected (criterion G).
H. Failure rate: Experimental groupDay 0Percentage of failures. After three failed punctures, the technique is considered as a failure.Percentage of failures. After three failed punctures, the technique is considered as a failure. Data collection using a standardized online electronic Case Report Form. The number of skin punctures will be counted. The criterion "failure" will be retained after 3 unsuccessful skin punctures. This requires a change of insertion site and withdrawal from the study. The other complication criteria mentioned above will still be recorded and analyzed but the time will not be collected (criterion G).

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 9, 2026