Acute Kidney Injury, Renal Replacement Therapy, Venoarterial Extracorporeal Membrane Oxygenation
Conditions
Keywords
VA-ECMO, RRT, connection, integrated, parallel, hemofilter
Brief summary
Extracorporeal membrane oxygenation (ECMO) is an extra-corporeal assistance used in case of respiratory or circulatory failure. In case of circulatory failure, ECMO is in the veno-arterial configuration (VA-ECMO). VA-ECMO patients are at high risk of developing acute kidney injury (AKI) and renal replacement therapy (RRT) may be needed in 50% of ECMO patients. Although the administration of RRT in ECMO patients has major implications, no specific recommendations are currently available. The 2020 Kidney Disease: Improving Global Outcomes (KDIGO) international conference identified the evaluation of RRT in these ECMO patients as a research priority. In 2023, the two main configurations used to administer RRT in ECMO patients are an independent delivery on a separate vascular access (parallel connection) or an integration of the RRT machine directly into the ECMO circuit (integrated connection). The integrated connection may reduce infectious and bleeding complications associated with the use of a second vascular access. However, it can expose the hemofilter and circuit to excessive positive pressures that can trigger pressure alarms in the RRT machine and expose the patient to a theoretical risk of air embolism or hemolysis. Furthermore, there is currently no robust data comparing the hemofilter lifespan with the parallel or with the integrated connection, although the filter lifespan is a crucial parameter to assess the quality of the RRT delivery in the ICU. The investigators recently performed a survey of practices in this context of ECMO patients. The investigators found that both strategies (parallel and integrated connection) are widely used and can be seen as common patient care. The hypothesis tested in this study is the following: when RRT is integrated to the ECMO circuit, the hemofilter lifespan is non inferior to the one when RRT is delivered on a separate vascular access. Only VA-ECMO patients will be enrolled in this trial.
Interventions
The RRT machine is connected on a separate vascular access (dialysis catheter).
A connection of the RRT machine with the input and output lines directly on the ECMO circuit.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients aged above 18 years * Patient on VA-ECMO who requires the initiation of continuous RRT during VA-ECMO treatment * Patient with a foreseeable length of stay in intensive care greater than 24 hours
Exclusion criteria
* Patient who does not have a vascular capital allowing for the insertion of a new dialysis catheter to administer RRT and therefore cannot be randomized to the parallel connection group * High pressures monitored on ECMO not allowing direct RRT catherter on ECMO * Pregnant, parturient, or breastfeeding women * Patient deprived of liberty by a judicial or administrative decision * Patient under psychiatric care * Patient subject to a legal protection measure (guardianship, curators) * Patient not affiliated to a social security system * Patient participating in another interventional research study in the field of extra purification renal
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Hemofilter change rate | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether integrated RRT connection in VA-ECMO patients results in a non-inferior hemofilter change rate compared to the parallel connection. The hemofilter change rate is defined as the number of hemofilter replacements observed during the period between the start and the end of the RRT session, normalized by the duration of the session. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Proportion of early hemofilter thromboses | Duration of RRT associated with VA-ECMO up to 60 days | To assess if the integrated RRT connection is associated with a lower proportion of early hemofilter thromboses compared to the parallel connection: number of early hemofilter thromboses normalized by the number of hemofilters used. "Early" is defined as \< 24 hours of use. |
| Proportion of hemofilter thromboses | Duration of RRT associated with VA-ECMO up to 60 days | To assess if the integrated RRT connection is associated with a lower proportion of hemofilter thromboses compared to the parallel connection: number of hemofilter thromboses normalized by the number of hemofilters used. |
| Down-time | Duration of RRT associated with VA-ECMO up to 60 days | To compare the integrated RRT connection to the parallel connection in terms of duration of non-purification periods in relation to the total duration RRT. |
| Number of infectious complications | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection reduces the number of infectious complications associated with the use of an additional vascular access. The infection will be defined as catheter-related in case of documented bacteraemia with positive blood cultures with differential time to positivity or positive catheter culture with the same microorganism. |
| Number of bleeding complications | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection reduces bleeding complications associated with the use of an additional vascular access. The occurrence of a bleeding syndrome is defined as a bleeding requiring transfusion with collection of the number of red blood cells transfused or requiring an invasive procedure (surgery, embolization), and defined or not as related to dialysis catheter placement or RRT connection to VA-ECMO. |
| Proportion of ECMO circuit thromboses | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection does not expose the ECMO circuit to a higher probability of thrombosis The occurrence of thrombosis on the ECMO circuit is defined as a thrombus on any part of the ECMO circuit requiring a change in the circuit or oxygenator, or on the oxygenator resulting in a deleterious effect on oxygenation, or resulting in significant fibrinolysis |
| Number of hemolysis | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection does not expose to a higher probability of hemolysis. The occurrence of intravascular hemolysis is defined as the occurrence of significant hemolytic anemia. |
| Number of air embolism | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection does not expose the patient to a higher probability of air embolism. The occurrence of an air embolism is defined as an embolic event with clinical impact of any kind, This occurence is related or not to the use of the dialysis catheter or the connection of the RRT to the VA-ECMO circuit. |
| Number of days spent in intensive care unit | Duration of RRT associated with VA-ECMO up to 60 days | To assess whether the integrated RRT connection modifies the intensive care unit length of stay |
| Renal function according to KDIGO stage | At hospital discharge up to 60 days after admission | To assess renal function at hospital discharge or at day 60 after admission. |
| Death | At 30 days | 30-day mortality |
Countries
France
Contacts
Hospices Civils de Lyon