Skip to content

A Trial to Compare Automated Lyumjev Delivery With Carbohydrate Counting, Qualitative Meal-size Estimation, and Meal Detection in Type 1 Diabetes

A Randomized, Crossover, Pilot Trial to Compare Automated Lyumjev Delivery With Carbohydrate Counting, Qualitative Meal-size Estimation, and Meal Detection in Type 1 Diabetes

Status
Recruiting
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06021158
Acronym
Lilly-MEALS
Enrollment
12
Registered
2023-09-01
Start date
2023-12-20
Completion date
2024-12-31
Last updated
2024-03-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Type 1, Type 1 Diabetes

Brief summary

The goal of this pilot trial is to compare three meal strategies using an ultra-rapid insulin (Lyumjev) and an automated insulin delivery system. The meal strategies to be investigated are carbohydrate counting, qualitative meal announcement (e.g., low-carb meal), and meal detection. The investigators are doing this research to evaluate if carbohydrate counting can be simplified in patients with type 1 diabetes. Participants will test each meal strategy in random order, and each meal strategy will be 21 days long. For the duration of each meal strategy, participants will use an automated insulin delivery system or artificial pancreas with an ultra-rapid insulin called Lyumjev.

Interventions

COMBINATION_PRODUCTHybrid automated Lyumjev delivery system with carbohydrate counting

In this system, a Lyumjev insulin bolus is initiated at mealtime based on the total grams of carbohydrates counted. This is the same as commercial hybrid closed-loop insulin therapy (standard treatment).

COMBINATION_PRODUCTHybrid automated Lyumjev delivery system with meal size estimation

In this system, a Lyumjev insulin bolus is initiated at mealtime based on the qualitative amount of carbohydrates estimated (e.g., low-carb meal).

COMBINATION_PRODUCTFully automated Lyumjev delivery system with meal detection

In this system, the patient does not initiate a Lyumjev insulin bolus at mealtime. An algorithm is used to detect a meal and administer a subsequent bolus, rather than requiring a carbohydrate count.

Sponsors

McGill University Health Centre/Research Institute of the McGill University Health Centre
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Clinical diagnosis of type 1 diabetes for at least 12 months. The diagnosis of type 1 diabetes is based on the investigator's judgment per local and international guideline criteria. * Insulin pump use for at least 3 months. * Individuals of childbearing potential must agree to use a highly effective method of birth control. * Willing to switch to Lyumjev insulin for the duration of the study.

Exclusion criteria

* Use of oral antihyperglycemic agents within 2 weeks of admission (SGLT2i, metformin…); 1 month for GLP1-RA. * Use of glucocorticoids (except low, stable doses and inhaled steroids). * Use of hydroxyurea. * Planned or ongoing pregnancy. * Breastfeeding. * Diabetic ketoacidosis and/or severe hypoglycemia episode (defined as requiring the assistance of another person, due to altered consciousness, to administer carbohydrates, glucagon, or other resuscitative actions) within one month of admission. * Clinically significant retinopathy, nephropathy, or neuropathy as judged by the investigator. * Recent (\<6 months) acute macrovascular event e.g., acute coronary syndrome or cardiac surgery. * Known hypersensitivity to the study drug or its excipients. * Other serious medical illness likely to interfere with study participation or with the ability to complete the trial, as judged by the investigator.

Design outcomes

Primary

MeasureTime frame
Percentage of time of glucose levels spent in the target range (3.9-10.0 mmol/L)14 days

Secondary

MeasureTime frame
Mean glucose levels14 days
Standard deviation of glucose levels14 days
Standard deviation of insulin delivery14 days
Coefficient of variance of glucose levels14 days
Coefficient of variance of insulin delivery14 days
Percentage of time of glucose levels spent in the following ranges: - between 3.9 and 7.8 mmol/L - below 3.9 mmol/L - below 3.0 mmol/L - above 10.0 mmol/L - above 13.9 mmol/L14 days
Area under the sensor glucose concentration-time curve (AUC) from 0-1 hours, 0-2 hours, 0-3 hours, 0-4 hours, and 0-5 hours after meal insulin boluses14 days
Area under the sensor glucose concentration-time curve (AUC) from 1-2 hours, 2-3 hours, 3-4 hours, and 4-5 hours after meal insulin boluses14 days
Decremental sensor glucose concentration for the duration of announced exercise periods14 days
Area under the sensor glucose concentration-time curve (AUC) from 0-1 hours, 0-2 hours, 0-3 hours, 0-4 hours, and 0-5 hours after the end of announced exercise periods14 days
Total insulin delivery (overall, basal, and bolus)14 days

Countries

Canada

Contacts

Primary ContactCarolyne Schumacher
carolyne.schumacher@mail.mcgill.ca514-258-5431

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 11, 2026