Skip to content

Clinical Application of Super-resolution Ultrasound(SR-US) Imaging in Solid Tumors

Clinical Application of Super-resolution Ultrasound(SR-US) Imaging in Solid Tumors

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06018142
Enrollment
100
Registered
2023-08-30
Start date
2022-06-01
Completion date
2025-02-28
Last updated
2023-08-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Microvessels, Neoplasm Metastasis, Neoplasms, Liver, Neoplasms Malignant, Ultrasound

Keywords

super-resolution ultrasound imaging, ultrasound, solid tumor, micro flow imaging, Microvessels

Brief summary

It has well accepted that tumor angiogenesis present aberrant vascular architecture and functional abnormalities, which is associated with tumorigenesis, tumor propagation and progression. By locating, separating and tracking microbubbles, the recently introduced and upgraded Ultrasound Localization Microscopy (ULM) surpassed classical wave diffraction limit. However, the acquisition of structural and functional parameters of microcirculation in vivo for ULM is still confined by the compromise between the resolution and penetration depth. The relatively long acquisition time induced the difficulty of motion correction potentially, which hampers the preclinical to clinical application in organs with distinct tissue motion such as the liver. Therefore, we take the lead in studying human liver lesion microvasculature, which remains a challenge for noninvasive, quantitative and functional intravital imaging especially due to its deep-seated location and strong motion. We developed a Super-resolution Ultrasound (SR-US) imaging technique based on ULM to assess its feasibility of visualizing and quantifying microvasculature in human organs.

Detailed description

In this study, 7 indexes were obtained by ultrasonic acquisition. These 7 indicators are used to describe and evaluate the microvessels in the tumor, so as to achieve the early identification and diagnosis of the tumor, and to monitor the growth of the tumor for a long time and evaluate the treatment of the tumor. This is not available with other ultrasound devices. Based on contrast-enhanced ultrasound, this technology can provide information of smaller blood vessels, which will certainly contribute to the early diagnosis and real-time evaluation of solid tumors during treatment, and play an important role in clinical application.

Interventions

None listed

Sponsors

Chinese PLA General Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Age over 18 years old, gender unlimited; 2. Patients with solid organ tumors with a maximum diameter \> 1cm; 3. No contraindications with contrast ultrasound agents; 4. It can improve the pathological results of the tumor or the diagnostic results supported by other relevant imaging tests. 5. Patients can understand the purpose of the examination, voluntarily participate and sign the informed consent.

Exclusion criteria

1. The subject is known to be allergic to any component of the contrast agent Sonovue; 2. Lesions were diffuse or borderless on contrast ultrasound; 3. Patients who underwent previous anti-angiogenesis and chemotherapy, or other local treatment of the tumor; 4. Poor image display or deep position in conventional ultrasound evaluation (\<10 cm from skin), 5. The researchers determined that there were any other factors that were not suitable for inclusion or affected participants' participation in the study 6. Patients with severe heart disease or lung disease; 7. Patients who are pregnant, may be pregnant or breastfeeding; 8. No enhanced MRI or enhanced CT results can be obtained; 9. The investigator considers the subjects unfit to participate in this study.

Design outcomes

Primary

MeasureTime frameDescription
Perfusion index30 minutesThe product of the average speed of microbubbles in region of interest (ROI) and the ROI area
Vessel diameter30 minutesTo describe the diameters of the tiniest blood vessels that can be explored
Vessel density30 minutesTo describe the ratio of the number of blood vessels in the tumor to the cross-sectional area of the tumor
Vessel density ratio30 minutesThe ratio of blood vessel density between the core and peripheral areas of the tumor
Mean flow velocity30 minutesThe average velocity in the region of interest
Distance metric30 minutesThe ratio of the total length of the curve path to the straight line distance from the beginning to the end of the curve
Perfusion ratio30 minutesPerfusion ratio of tumor core to peripheral area

Countries

China

Contacts

Primary ContactJie Yu, Doctor
liangping301@126.com010-66937981

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 6, 2026