Colorectal Cancer, Continuous Glucose Monitoring
Conditions
Keywords
cgm, Colorectal Cancer, continuous glucose monitoring
Brief summary
Hyperglycemia commonly occurs during surgery due to a reaction to metabolic stress and trauma. It has been shown that improper glycemia control leads to impaired wound healing and a higher risk of other postoperative complications. The primary aim of our project is to assess the feasibility of the use of continuous glucose monitoring in measuring blood glucose levels in patients undergoing colorectal cancer surgery. The secondary aim is to analyze changes in perioperative blood glucose levels to understand the effects of stress and intraoperative interventions on the blood glucose level. The tertiary goal is to assess the predictive value of hyperglycemia for surgical site infection.
Detailed description
Hyperglycemia commonly occurs during surgery due to a reaction to metabolic stress and trauma. It has been shown that improper glycemia control leads to impaired wound healing and a higher risk of other postoperative complications. However, glucose levels measured in patients before surgery are taken infrequently, and there remains controversy regarding optimal management. Usually, a blood glucose meter is used to measure non-fasted blood glucose concentrations, and a single-point measurement can easily misrepresent the actual glycemic control. Continuous glucose monitoring allows for a minimally invasive real-time remote glycemia control and is providing insights into glucose regulation in patients, demonstrating significant periods of clinically silent hypoglycemia and hyperglycemia. The primary aim of our project is to assess the feasibility of the use of CGM in measuring blood glucose levels in patients undergoing colorectal cancer surgery. The secondary aim is to analyze changes in perioperative blood glucose levels to understand the effects of stress and intraoperative interventions on the blood glucose level. The tertiary goal is to assess the predictive value of hyperglycemia for surgical site infection.
Interventions
FreeStyle Libre 3 system consists of a sensor that measures interstitial glycemia every minute and a dedicated application on mobile phone. Measurements are transmitted via Bluetooth to a mobile phone, that collects the data in the mobile application. Moreover, the study subject's application is connected to the doctor's application which allows remote real-time glycemia monitoring on another device. Other Name: continuous glucose monitoring, CGM, FreeStyle Libre 3
Sponsors
Study design
Eligibility
Inclusion criteria
* written informed consent * confirmed colorectal cancer qualified for surgery
Exclusion criteria
* patients who will be unable or will refuse to express informed concern * pregnant women * people undergoing dialysis treatment
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| feasibility of CGM system | 10 days | measured as the drop-out rate caused by non-adherence of both patients and medical staff due to system detaching, problems with the receiving device (low battery. distance beyond Bluetooth communication range) etc. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| perioperative glycemia | 10 days | number of hyperglycemia episodes impact of stress and intraoperative interventions on the blood glucose level |
| SSI rate | 30 days | Surgical Site Infection according to Centre for Disease Control criteria: Infection occurring within the first 30 post-operative days with at least one of the following: Purulent drainage from the incision Organisms isolated from an aseptically obtained culture of fluid or tissue from the incision Incision is deliberately opened by a surgeon AND at least one of the following signs/symptoms of infection: Pain or tenderness Localized swelling Redness Heat Diagnosis of SSI by the surgeon or attending physician |
Countries
Poland