Skip to content

Study of the Resvent RXiBreeze™ PAP System to Treat Obstructive Sleep Apnea

A Multicenter, Single-Arm, Safety and Efficacy Study of the Resvent RXiBreeze™ PAP System to Treat Obstructive Sleep Apnea

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06008678
Enrollment
146
Registered
2023-08-23
Start date
2023-08-22
Completion date
2023-11-29
Last updated
2024-12-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obstructive Sleep Apnea

Keywords

obstructive sleep apnea, sleep apnea, CPAP, PAP, APAP

Brief summary

The goal of this clinical trial is to test the automatic positive airway pressure (APAP) function of the RXiBreeze PAP System in adult subjects with obstructive sleep apnea (OSA). The main questions the study aims to answer are: 1. Is apnea-hypopnea index (AHI) detection using the RXiBreeze PAP System equivalent to apnea-hypopnea index (AHI) detection using PSG? 2. What is the responder rate using the RXiBreeze PAP System? Participants will use the APAP function of the RXiBreeze PAP System while undergoing polysomnography (PSG) for two separate nights in a sleep center. During each visit, participants will also complete two patient reported outcome questionnaires: * Epworth Sleepiness Score (ESS); and * Functional Outcomes of Sleep Questionnaire (FOSQ) short form.

Detailed description

This is a prospective, multicenter, single-arm trial designed to evaluate the safety and effectiveness of the RXiBreeze PAP System to treat obstructive sleep apnea and detect breathing events. Eligible subjects who meet all inclusion criteria and none of the exclusion criteria will be consented for study participation. The study will enroll up to 68 subjects. Baseline PSG will be obtained. Subjects will return to the sleep lab and use the RXiBreeze PAP System while undergoing a PSG. The data from both the RXiBreeze PAP System and PSG from both nights will be sent to an independent core lab for blinded AHI scoring. Data will be evaluated in accordance with current American Academy of Sleep Medicine (AASM) scoring guidelines. In addition to the device/PSG data scoring, subjects will complete the Epworth Sleepiness Score (ESS) and the Functional Outcomes of Sleep Questionnaire (FOSQ) short form (10 questions) and be assessed for device- and/or therapy-related adverse events (AEs) at the end of each visit.

Interventions

DEVICERXiBreeze PAP System, Model RXiBreeze 20A

The RXiBreeze PAP System is a prescription-only positive airway pressure (PAP) ventilator used to treat obstructive sleep apnea (OSA). It is a microprocessor-controlled device that provides mechanical ventilation to a subject.

Sponsors

Avania
CollaboratorINDUSTRY
Resvent Medical Technology Co., Ltd.
CollaboratorINDUSTRY
Resvent Holding USA LTD
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

single-arm trial

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subject is ≥ 22 years old 2. Subject has been diagnosed with OSA (as scored per AASM scoring guidelines) and has an AHI ≥ 10, based on the results of a sleep study conducted at an accredited sleep lab, within 30 days prior to enrollment 3. Subject weighs \>30 kg 4. Subject has been prescribed the use of an Auto CPAP system 5. Subject agrees to fulfill all study-required tests, sleep lab session attendance, and assessments 6. Subject agrees to use the RXiBreeze PAP System as prescribed 7. Subject is willing and able to provide informed consent

Exclusion criteria

1. Subject has been diagnosed with a sleep disorder other than OSA 2. Subject's Central Apnea Index from the baseline PSG is \> 20% of AHI 3. Subject has been diagnosed with severe (stage 3) coronary artery disease 4. Subject has been diagnosed with bullous lung disease 5. subject has been diagnosed with hypotension 6. subject has been diagnosed with bypassed upper airway pneumothorax 7. Subject is pregnant, breastfeeding, or planning on becoming pregnant during trial participation 8. Subject, in the opinion of the investigator, is not suitable for trial participation

Design outcomes

Primary

MeasureTime frameDescription
Responder RateNight 1RXiBreeze PAP System Night 1 responder rate as compared to a performance goal of 50. Responder rate is based on Sher's Criteria, which are defined as having both a ≥ 50% reduction in AHI and a final AHI of \< 20 events per hour.
AHI Event DetectionNight 1Apnea-Hypopnea Index (AHI) as measured by the test device (RXiBreeze PAP System) will be compared to the AHI as measured by polysomnography (PSG) to determine equivalence at night 1. Equivalence will be considered if the mean difference in detected AHI is greater than the lower equivalence limit (EL) of -5 and less than the upper equivalence limit (EU) of 5.

Secondary

MeasureTime frameDescription
Night 1 responder rate by baseline disease severityNight 1Responder rate presented by disease severity in accordance with AASM scoring guidelines. Responder rate is based on Sher's Criteria, which are defined as having both a ≥ 50% reduction in AHI and a final AHI of \< 20 events per hour.
Night 7 RXiBreeze PAP System compliance rateNight 7Compliance rate is measure of subject use of the RXiBreeze PAP System presented by descriptive statistics.
Nights 1 and 7 Oxygen Desaturation Index (ODI)Nights 1 and 7ODI is average number of desaturation episodes per hour. ODI will be presented by descriptive statistics.
Nights 1 and 7 percentage of time oxygen saturation is < 90% (T90)Nights 1 and 7Oxygen saturation is a measure of the amount of oxygen that is circulating in the blood. T90 oxygen saturation will be presented by descriptive statistics.
Event Detection Validation - Obstructive Apnea Index (OAI) on Night 1 and Night 7Nights 1 and 7Obstructive Apnea Index (OAI) as measured by the test device (RXiBreeze PAP System) will be compared to the OAI as measured by polysomnography (PSG) to validate accuracy of the test device at nights 1 and 7. Frequency and percentages will be presented.
Event Detection Validation: Central Apnea Index (CAI) on Night 1 and Night 7Nights 1 and 7Event Detection Validation: Central Apnea Index (CAI) as measured by the test device (RXiBreeze PAP System) will be compared to the CAI as measured by polysomnography (PSG) to validate accuracy of the test device at nights 1 and 7. Frequency and percentages will be presented.
Event Detection Validation: Apnea Index (AI) on Night 1 and Night 7Nights 1 and 7Event Detection Validation: Apnea Index (AI) as measured by the test device (RXiBreeze PAP System) will be compared to the AI as measured by polysomnography (PSG) to validate accuracy of the test device at nights 1 and 7. Frequency and percentages will be presented.
Epworth Sleepiness Scale (ESS) on Night 1 and Night 7Nights 1 and 7Epworth Sleepiness Scale (ESS) is a validated patient reported outcome (PRO) questionnaire consisting of 8 questions related to daytime sleepiness. The ESS results in a score from 0 to 24 (0 - 10 reflect normal levels of daytime sleepiness, scores over 10 reflect excessive daytime sleepiness (EDS), scores of 16 or more suggest a high level of EDS. The ESS will be self-administered by subjects at the Night 1 and Night 7 visits. Results will be presented by frequency and percentages.
Functional Outcomes of Sleep Questionnaire short form (FOSQ-10) on Night 1 and Night 7Nights 1 and 7Functional Outcomes of Sleep Questionnaire (FOSQ) short form is a validated patient reported outcome (PRO) questionnaire consisting of 10 questions related to the impact of sleepiness on the ability to conduct daily activities. The FOSQ-10 questions are rates on a scale of 1 to 4 (1=extreme difficulty and 4=no difficulty). A total score and 5 subscale scores (vigilance, general productivity, social outcome, intimacy, and activity level) are calculated. Subscale scores range from 1 (maximum difficulty) to 4 (no difficulty).
Event Detection Validation: Hypopnea Index (HI) on Night 1 and Night 7Nights 1 and 7Event Detection Validation: Hypopnea Index (HI) as measured by the test device (RXiBreeze PAP System) will be compared to the HI as measured by polysomnography (PSG) to validate accuracy of the test device at nights 1 and 7. Frequency and percentages will be presented.
Night 7 responder rateNight 7. Responder rate is based on Sher's Criteria, which are defined as having both a ≥ 50% reduction in AHI and a final AHI of \< 20 events per hour.

Other

MeasureTime frameDescription
Safety Endpoint: Device- and/or therapy-related adverse events (AEs)Night 1 through completion of Night 7Device- and/or therapy-related adverse events (AEs) will be collected from the Night 1 visit through completion of the Night 7 visit. AEs will be coded using the standardized Medical Dictionary for Regulatory Activities (MedDRA). AEs will be reported by subject and event.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026