Blood Lactate Decrease
Conditions
Keywords
Voluntary Isocapnic Hyperpnea, Lactate Clearance
Brief summary
All the study participants performed the Wingate Anaerobic Test (WAnT) with maximal effort. The experimental group (E) performed a 3-minute recovery protocol based on low-intensity breathing Voluntary Isocapnic Hyperpnea exercises 20 minuter after cessation of the exercise, whereas the control group (C) used passive recovery only. All study participants were advised to sit during the 30-minute period, with minimal walking in order to meet the physiological needs allowed. The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE) (Borg, 1998).
Detailed description
All the study participants performed the Wingate Anaerobic Test (WAnT) with maximal effort. The experimental group (E) performed a 3-minute recovery protocol based on low-intensity breathing VIH exercises 20 minuter after cessation of the exercise, whereas the control group (C) used passive recovery only. All study participants were advised to sit during the 30-minute period, with minimal walking in order to meet the physiological needs allowed. The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE). WAnT was conducted using a Monark 874E Cycle Ergometer (Monark Exercise AB, Sweden). Prior to the test, a standard warm-up of 5 minutes was performed with a load of 0.8-1.2 W/kg. Then, athletes performed a maximal 6-second sprint with a load adjusted to 7.5% of the individual body weight. Following a 2-minute rest period, the athletes underwent a 30-second WAnT with the load adjusted to 7.5% of the individual body weight. The objective for the subjects was to achieve the highest possible peak power as fast as possible and maintain the highest power output throughout the whole test duration. Loud and dynamic verbal encouragement was provided. The testing took place between 9:00 and 10:30 AM. The basic mechanical parameters of the exercise, including performed work and maximum power, were computed with dedicated software (MCE 6.0 - JBA Z. Staniak, Poland) linked to the cycle ergometer. The recovery protocol consisted of 3' of breathing with 20 breaths·min-1 frequency. The Isocapnic BreathWayBetter devices (Isocapnic Technologies Inc, Kelowna, Canada) with 6-liter bags were used. The protocol was performed in a seating position. Blood samples were taken from fingertips by skilled technicians to 20 uL capillary tubes. bLa was measured with Super GL2 analyzer (Dr. Müller Gerätebau GmbH, Freital, Germany). Whereas participants and data collectors were aware of the allocated training method, the laboratory technicians performing biochemistry assays were kept blinded to the allocation. The participants were assigned at random to either E or C group to perform VIH protocol under a supervision of qualified physiotherapist. Stratified randomization to assign the participants was used. First, the participants were assigned to subgroups based on the membership in National Development or National Elite Team. Then, the participants were assigned to subgroups based on the gender. Then, the participants were assigned to E or C group based on the coin toss.
Interventions
The protocol of 3' of breathing with 20 breaths·min-1 frequency. The Isocapnic BreathWayBetter devices (Isocapnic Technologies Inc, Kelowna, Canada) with 6-liter bags were used. The protocol was performed in a seating position.
Sponsors
Study design
Intervention model description
Parallel Group Randomized Controlled Trial
Eligibility
Inclusion criteria
The inclusion criteria: * valid medical certificate to compete in speedskating, * lack of previous experience with RMT, * at least 6 years of athletic training. The
Exclusion criteria
* any chronic medical condition, * any acute medical condition within last 3 months, * any ongoing medication intake.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Changes in blood lactate (bLa) | 30 minutes | The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. Blood samples were taken from fingertips by skilled technicians to 20 uL capillary tubes. bLa was measured with Super GL2 analyzer (Dr. Müller Gerätebau GmbH, Freital, Germany). |
| Changes in rate of perceived exertion (RPE) | 30 minutes | The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE) (Borg, 1998). |
Countries
Poland