Skip to content

Safety and Effectiveness Study of SQ-Kyrin TMVr System for Functional Mitral Regurgitation

A Prospective, Multicenter, Single Arm Clinical Trial to Evaluate the Safety and Effectiveness of Transcatheter Mitral Valve Clip Delivery System and Steerable Guide Catheter in Patients With Moderate-severe or Severe Functional MR (FMR)

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05988450
Enrollment
125
Registered
2023-08-14
Start date
2022-03-07
Completion date
2027-12-31
Last updated
2023-08-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Functional Mitral Regurgitation

Keywords

Functional Mitral Regurgitation, Mitral Regurgitation

Brief summary

To verify the safety and effectiveness of transcatheter mitral valve clip delivery system and steerable guide catheter produced by Shanghai Shenqi Medical Technology Co., Ltd. in patients with moderate-severe (3 +) or severe (4 +) functional MR (functional MR) who still have symptoms after full treatment.

Detailed description

This study is a prospective, multi-center, single arm clinical study designed to evaluate the safety and effectiveness of transcatheter mitral valve clip delivery system and steerable guide catheter in patients with moderate-severe (3 +) or severe (4 +) functional MR (Functional MR) who still have symptoms after adequate treatment. This trial will be conducted at 41 sites in China and is planned to include a total of 118 subjects. All subjects received the trial device for transcatheter mitral valve clip delivery system and steerable guide catheter, and were followed up at 30 days, 6 months, and 12 months after surgery. The composite endpoint of all-cause death and hospitalization for heart failure was assessed at 12 months after surgery. After the 12th month follow-up, the statistical analysis, clinical summary and application for product registration were carried out.

Interventions

Transcatheter mitral valve clip placement to repair the valve and correct regurgitation.

Sponsors

Shanghai Shenqi Medical Technology Co., Ltd
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Severe functional MR (FMR) ≥3+ as determined by transthoracic echocardiography (TTE); 2. Note: Eligible TTE must be obtained at least 30 days after the subject has been stabilized on optimal therapy (including Guideline Directed Medical Therapy GDMT). In the judgment of the center's cardiac team, subjects have received adequate treatment according to applicable criteria, including treatment for coronary artery disease, left ventricular dysfunction, MR, and heart failure (e.g., with cardiac resynchronization therapy (CRT or CRT-D), implantable cardioverter-defibrillator (ICD) implantation, coronary revascularization, and stable GDMT (see Appendix III for the definition of GDMT). 3. Age ≥ 18 years old, regardless of gender; 4. Cardiac function classification NYHA class II, III or ambulatory IV a; 5. At least one hospitalization for heart failure or subjects with high BNP \> 150 pg/ml or high NT-proBNP \> 600 pg/ml in the past 12 months. 6. Note: BNP or NT-proBNP must be obtained after the subject has stabilized on optimal therapy including Guideline Directed Medical Therapy (GDMT) at least 30 days. The patients can understand the purpose of the trial, voluntarily participate and sign an informed consent form, and are willing to undergo relevant tests and clinical follow-up. 7. Left ventricular end-systolic diameter (LVESD)≤70mm 8. The MR beam mainly originates from the A2/P2 area 9. Mitral valve coaptation depth≤11mm, coaptation height≥2mm, effective length of anterior and posterior leaflets\>10mm 10. Mitral valve effective orifice area (EOA) ≥ 4.0cm2

Exclusion criteria

1. History of mitral valve surgery; 2. Patients with infective endocarditis or suggestive of active infection; 3. Complicated with severe untreated coronary artery disease; 4. Patients with pulmonary hypertension (pulmonary systolic blood pressure\>70mmHg); 5. patients with transthoracic echocardiographic evidence of moderate-severe to severe right ventricular dysfunction; 6. Left heart ejection fraction \<20%; 7. Patients who are extremely frail and cannot tolerate general anesthesia surgery or is in the state of shock requiring circulatory support; 8. Patients diagnosed with hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis; 9. Severe renal insufficiency (eGFR ≤ 25 mL/min) or requiring chronic renal replacement therapy; 10. Patients with definite coagulation disorders and severe coagulation system diseases; 11. Patients with clear contraindications to the use of anticoagulants; 12. Patients with stroke or transient cerebral ischemic attack within 30 days; 13. Received cardiac pacemaker therapy or cardiac resynchronization therapy (CRT, CRT-D) or implanted cardioverter-defibrillator (ICD) implantation therapy within 30 days; 14. Any intracardiac mass, left ventricular or atrial thrombus detected on transthoracic echocardiography; 15. Severe tricuspid TR; 16. Patients with other valve disease requiring surgery or interventional therapy; 17. Patients with severe macrovascular disease requiring surgical treatment; 18. Severe symptomatic carotid stenosis (\>70% on ultrasonography) or carotid stenting within 30 days; 19. Patients with inappropriate anatomical structures of the heart and valves indicated by imaging examinations; 20. Known allergy to contrast agents and nickel-titanium memory alloy products; 21. \<Resting systolic blood pressure 90 mmHg or \>160 mmHg; 22. Patients with diseases that seriously affect the evaluation of treatment, such as patients with severe neurological lesions affecting cognitive ability, patients with malignant tumors, etc.; 23. Patient life expectancy \< 12 months; 24. Patients with severe thoracic deformity; 25. Women who are pregnant, breastfeeding, or planning to become pregnant within the next 12 months.

Design outcomes

Primary

MeasureTime frameDescription
Rate of all-cause death and hospitalization for heart failure12 monthsFreefrom of all-cause death and hospitalization for heart failure

Secondary

MeasureTime frameDescription
Device success rate30 days after surgery1. Successfully implanted valve clip 2. Transthoracic echocardiographic assessment showing MR ≤2+
Surgical success rate30 days after surgery1. Device success 2. No major adverse events occurred The major adverse event refers to the composite endpoint of death, stroke, myocardial infarction, and cardiovascular surgery due to device- or surgery-related adverse events following the atrial septum pathway via the femoral vein.
Rate of MR 2+ or less than 2+ at 30 days, 6 months, and 12 months after surgery;30 days, 6 months, and 12 months after surgeryRate of MR 2+ or less than 2+ at 30 days, 6 months, and 12 months after surgery;
Rate of hospitalization for heart failure at 30 days, 6 months, and 12 months after surgery;30 days, 6 months, and 12 months after surgeryRate of hospitalization for heart failure at 30 days, 6 months, and 12 months after surgery;
Technical success rateImmediate postoperative1. No surgical death 2. Delivery system for successful delivery and retrieval of devices 3. Successful devices release and accurate positioning 4. No need for any emergency surgery related to the device or surgical approach
Improvement in quality of life from baseline at 12 months after surgery (as assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ) score);12 months after surgeryImprovement in quality of life from baseline at 12 months after surgery (as assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ) score);
Improvement in 6-minute walk distance from baseline at 12 months after surgery;12 months after surgeryImprovement in 6-minute walk distance from baseline at 12 months after surgery;
Improvement in left ventricular end-diastolic volume (LVEDV) from baseline at 12 months after surgery;12 months after surgeryImprovement in left ventricular end-diastolic volume (LVEDV) from baseline at 12 months after surgery;
The rate of NYHA heart function class I or II at 30 days, 6 months, and 12 months after surgery;30 days, 6 months, and 12 months after surgeryThe rate of NYHA heart function class I or II at 30 days, 6 months, and 12 months after surgery;

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026