Skip to content

Microfluidic Chip Method Versus Density Gradient Centrifugation Method on Semen Parameters

Effect of Sperm Preparation by a Microfluidic Chip Method Versus a Density Gradient Centrifugation Method on Semen Parameters

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05978947
Enrollment
80
Registered
2023-08-07
Start date
2023-07-01
Completion date
2025-03-31
Last updated
2024-12-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Infertility

Keywords

Semen parameters, Microfluidic chip, Density Gradient Centrifugation

Brief summary

Infertility affects many couples, with male infertility being a common cause. In vitro fertilization (IVF) is an effective treatment, but its success rates are not high. Semen quality can affect IVF outcomes, and the current method used to process semen can damage the sperm and DNA. Scientists are now testing a new method called microfluidic chip technology, which reduces DNA damage and increases sperm movement. This study will compare the effectiveness of the chip method and the current method on semen quality in men attending a fertility clinic. The study will randomly assign semen collected to one of the two methods and assess the semen quality using different tests, as well as the difference in using two different microfluidic chip platform . The primary outcome will be DNA fragmentation, and other outcomes include sperm count and motility. Semen samples would be collected from study subjects for analysis and that both the samples and results would not be used in patients' treatment.

Detailed description

Infertility affects one in six couples and is getting more common as many women delay marriage and childbirth for various reasons. In vitro fertilization (IVF) is the most effective treatment for couples with long standing infertility and has treated millions of infertile couples over the world since the first birth of IVF was reported more than 40 years ago. However, despite advances in technology, the pregnancy and birth rates remain around 35% and 25% per transfer in Europe in 2018. Among all infertile couples, 20-30% are due to male infertility. Semen parameters may affect the IVF outcomes and it was hypothesized that the relative contribution of sperm to a live birth is around 10-15%. IVF involves hormone injections to stimulate a woman's ovaries to produce a number of oocytes which are collected by a minor operation and then mixed with sperm to form embryos in the laboratory. Usually, one or two embryos are transferred to the uterus 2-5 days after oocyte retrieval. In IVF, semen samples produced by husbands are commonly processed by a density gradient centrifugation method to isolate the better spermatozoa for fertilization. The density gradient centrifugation can enrich spermatozoa with relatively good motility and normal morphology. It is possible to recover spermatozoa from semen specimens with a very low sperm density. It can provide a relatively good yield. However, it requires technical training to set up the density gradient consisting of two media with different densities. During semen processing, spermatozoa are centrifuged through the gradient. It is known that centrifugation causes considerable damage to spermatozoa by the reactive oxygen species produced during the process. Reactive oxygen species are known to be one of the major causes leading to sperm DNA fragmentation and subsequent adverse outcomes including implantation failure and miscarriage. A meta-analysis showed sperm DNA damage has a negative effect on clinical pregnancy following IVF. A microfluidic chip, which is a miniaturized device containing channels and chambers in the microscale range for nanoparticle preparation, is being used as an alternative sperm preparation technique recently. By employing microfluidic technology, spermatozoa can go through the chip that closely simulates the natural selection in the female genital tract microenvironment. The technology enables the selection of high-quality motile spermatozoa from semen samples without the need for centrifugation, leading to reduced reactive oxygen species formation. Studies have consistently demonstrated that the use of a microfluidic chip method greatly reduces DNA fragmentation and increases motility when compared with the density gradient centrifugation method. This randomized controlled trial aims compare the effect of sperm preparation by a microfluidic chip method versus a density gradient centrifugation method on semen parameters prior to the start of a randomized trial comparing the effects of the two sperm preparation methods on the cumulative live birth rates of in vitro fertilization. Objectives: The first objective of this randomized controlled trial is to compare the effect of sperm preparation by a microfluidic chip method versus a density gradient centrifugation on semen parameters. The hypothesis is that the use of sperm preparation by a microfluidic chip method improves semen parameters. The second objective is to compare the effect of two different microfluidic chip platforms on semen parameters. Trial design: Men attending at the Centre of Assisted Reproduction and Embryology, Queen Mary Hospital for fertility treatment will be recruited.

Interventions

DEVICEZyMōt Multi 850µL device

The ZyMōt Multi 850µL device is a laboratory tool designed for use in assisted reproductive technology (ART) procedures such as intrauterine insemination (IUI) and in vitro fertilization (IVF). It is a sperm preparation device that uses a proprietary patented technology to isolate and select motile sperm from semen samples for use in ART procedures.

DEVICEDensity Gradient Centrifugation Method

Density gradient centrifugation is a laboratory technique used to separate and isolate different types of cells or particles based on their density. It is commonly used in various applications, including cell biology, immunology, and assisted reproductive technology (ART).

Sponsors

Professor Ernest Hung-Yu Ng
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Masking description

Only the laboratory staff in the IVF laboratory performing sperm preparation will be aware of the group assignment. Another laboratory staff who is not involved in performing sperm preparation and is not aware of the group assignment will perform the semen analysis.

Intervention model description

This randomized controlled trial aims compare the effect of sperm preparation by a microfluidic chip method versus a density gradient centrifugation method on semen parameters prior to the start of a randomized trial comparing the effects of the two sperm preparation methods on the cumulative live birth rates of in vitro fertilization.

Eligibility

Sex/Gender
MALE
Healthy volunteers
Yes

Inclusion criteria

* Sperm concentration of the raw semen with at least 5 million motile sperm per ml with a total volume of not less than 1.5ml.

Exclusion criteria

* Sperm concentration of the raw semen of less than 5 million motile sperm per ml * Men unable to provide an ejaculated semen sample

Design outcomes

Primary

MeasureTime frameDescription
DNA fragmentation by Comet assay1 monthsMeasurement of DNA fragmentation by Comet assay using the Olive tail moment as the quantitative metric.

Secondary

MeasureTime frameDescription
Forward motility1 monthsAssessment of forward motility of sperm by manual observation using the World Health Organization (WHO) criteria.
Sperm velocities measured by CASA1 monthsQuantitative analysis of sperm velocities using computer-assisted sperm analysis (CASA) system, including assessment of forward motility, curvilinear velocity, and linearity.
Morphology1 monthsQuantitative assessment of sperm morphology by manual observation using the Tygerberg strict criteria.
Sperm count1 monthsSperm count
Calcium ionophore A23187 -induced acrosome reaction assay1 monthsQuantitative measurement of acrosome reaction in sperm induced by calcium ionophore A23187 using flow cytometry.
Artificial intelligence analysis1 monthsQuantitative analysis of sperm morphology using artificial intelligence algorithms.
Intact oocyte/hemizona binding assay1 monthsQuantitative measurement of sperm binding to intact oocytes or hemizona using the intact oocyte/hemizona binding assay.
Sperm aneuploidy1 monthsQuantitative measurement of sperm aneuploidy by fluorescence in situ hybridization (FISH) using probes for chromosomes X, Y, 13, 18, and 21.

Countries

China

Contacts

Primary ContactYU WING TONG, MBBS
ptong@connect.hku.hk92707722

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026