The Accuracy of Computer Software Prediction of Soft Tissue Profile for Patients Undergoing Fixed Orthodontic Treatment

The Accuracy of Computer Software Prediction of Soft Tissue Profile for Patients Undergoing Fixed Orthodontic Treatment

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05978856
Enrollment
30
Registered
2023-08-07
Start date
2023-08-01
Completion date
2025-03-01
Last updated
2023-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental Malocclusion

Keywords

VTO, orthodontic software, prediction

Brief summary

A clinical study to evaluate the accuracy of computer software in predicting soft tissue profile changes in patients undergoing fixed orthodontic treatment

Detailed description

The computer software programs exhibit certain soft tissue simulation . The purpose of the study to assess the accuracy of computer software in predicting profile changes in patients undergoing fixed orthodontic treatment

Interventions

OTHERAccuracy of computer software in predicting soft tissue profile changes

Separate analyses will be performed on the initial and final cephalograms. * All of the cephalometric analyses will be done via computer software,the linear and angular measurements will be done via the software. * Through the use of software, the initial cephalogram and the initial photograph will be linked. * Then, the final values of some angles will be tracted from the post-treatment cephalogram. * These values will be inserted in the treatment simulationsection of the software. * A post-treatment projected image of the patient will be simulated by the software. * Then the actual post-treatment photograph will be placed on the simulated image in transparent form. * From the pupil , real horizontal and vertical reference lines will be drawn. * Then certain measurements will be taken from referance lines to fixed points on the soft tissue to determine the discrepancies between the real and simulated images.

Sponsors

Al-Azhar University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
15 Years to 35 Years
Healthy volunteers
Yes

Inclusion criteria

The inclusion criteria included: * Patient undergo fixed orthodontic treatment with the edgewise technique. * Skeletal class I. * Dental class I or II or III. * Final class I occlusion without spacing or crowding, with normal overjet and overbite (2-4 mm) * Availability of full diagnostic and therapeutic records before to and following orthodontic treatment, including medical and dental history, dental casts, panoramic and cephalometric x-rays, and photographic photographs. The

Exclusion criteria

included: * Missing tooth or significant Bolton discrepancies (more than 3 mm). * Craniofacial syndromes or skeletal abnormalities. * Failed orthodontic treatment in the past. * Cosmetic or reconstructive facial surgery during orthodontic treatment, or up to a year beforehand. * Using drugs that could reduce the volume of soft tissues.

Design outcomes

Primary

MeasureTime frameDescription
accuracy of computer software in predicting soft tissue profile changesthrough study completion, an average of 1 year* Separate analyses will be performed on the initial and final cephalograms. * All of the cephalometric analyses will be done via computer software; the linear and angular measurements will be done via the software. * Through the use of software, the initial cephalogram and the initial photograph will be linked. * Then, the final values of some angles will be extracted from the post-treatment cephalogram. * These values will be inserted in the treatment simulation section of the software. * A post-treatment projected image of the patient will be simulated by the software. * Then the actual post-treatment photograph will be placed on the simulated image in transparent form. * From the pupil , real horizontal and vertical reference lines will be drawn. * Then certain measurements will be taken from reference lines to fixed points on the soft tissue to determine the discrepancies between the real and simulated images.

Countries

Egypt

Contacts

Primary Contactsalah hasan, gp
dr.salah.hassan.1995@gmail.com01125237178