Skip to content

Ultra-wide Diameter Implants in Mandibular Molars

Evaluation of Immediately Placed Ultra-wide Diameter Implant Placed in Mandibular Molars

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05972447
Acronym
UWD
Enrollment
12
Registered
2023-08-02
Start date
2021-05-20
Completion date
2022-03-03
Last updated
2023-08-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental Implants

Keywords

UWD implants

Brief summary

The goal of this \[clinical trial\] is to \[To evaluate both the clinical and radiographical outcome on osteointegration and peri-implant bone density when using ultra wide diameter implant placed immediately in molar extraction socket\]

Detailed description

the aim of this study is to evaluate the clinical and radiographical outcomes on osseointegration and peri-implant bone density when using 12 ultrawide diameter dental implants placed immediately in 12 patients after atraumatic extraction of non-restorable mandibular molars without raising a flap or using bone grafts.

Interventions

PROCEDUREImmediate implant placement of Ultrawide diameter dental implants

immediate placement of ultrawide diameter dental implants in a fresh extraction socket of mandibular molar teeth

Sponsors

Abdelrahman Elshahawy
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

Adult patients ranging from 20-40 years. * Adequate bone beyond teeth apices without jeopardizing any anatomical structure. * Non-restorable mandibular molar teeth. * Available bone with adequate width and buccolingual dimensions. * Peri-implant bone defect should be 2mm or lesser.

Exclusion criteria

* Smokers. * Medically compromised patients like uncontrolled diabetes and coagulation disorders. * Tooth with periapical pathosis or bony defects.

Design outcomes

Primary

MeasureTime frameDescription
the mean value of implant stabilityup to 6monthsThe implant stability was measured by implant stability meter (Osstell™) immediately postoperative and at 6 months.
the mean value of peri-implant bone densityup to 9 monthsRadiographic evaluation of the bone density around each implant was done using OnDemand3D™.
the mean value of Marginal bone lossup to 9monthsmarginal bone levels were calculated from the reconstructed corrected sagittal views by drawing a line parallel to the implant serration extending from the crestal bone to the apical end of the implant. Average readings of the two sides at each interval were calculated and tabulated for statistical analysis.
the mean of peri-implant probing depthup to 9 monthsProbing depth was assessed according to Gallagher and Silver Probing pocket depth refers to the distance between the gingival margin and the bottom of the pocket

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026