Skip to content

Kinetics of Extracellular Vesicles in Hemodialysis

Kinetics of Extracellular Vesicles in Hemodialysis

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05957146
Enrollment
6
Registered
2023-07-24
Start date
2023-11-07
Completion date
2024-02-09
Last updated
2024-10-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

End-stage Kidney Disease

Keywords

Hemodialysis, Extracellular vesicles, Bio-incompatibility, Tissue injury

Brief summary

The aim of this observational study is to gain insight into the kinetics of extracellular vesicles (EVs), derived from both in- (i.e. bio-incompatibility) and outside (tissue-injury) the extracorporeal circuit (ECC), during standard hemodialysis (HD) in adult prevalent end-stage kidney disease (ESKD) patients treated with HD. During a single HD session, blood samples for EV-assessment will be taken at several time points and at different sampling sites in the extracorporeal circuit (sampling point 1: before the rollerpump, arterial line; sampling point 2: after the rollerpump and before the dialyzer, sampling point 3: after the dialyzer, efferent line).

Detailed description

Hemodialysis (HD) is a lifesaving treatment for ESKD patients. Yet, apart from beneficial effects, HD has adverse consequences, which, apart from rapid osmolality and electrolyte shifts, results from the bio-incompatibility (BI) of the extra-corporeal circuit (ECC) and intradialytic hypotension (IDH) as well. While BI arises within the ECC due to the contact between circulating blood cells and the foreign materials of the lines and dialyzer, IDH-induced tissue injury (TI) originates within the body of the patients. Activated cells can be detected by upregulation of cell surface markers and release of degradation products. Substances which are smaller than the pores of dialyzer-membranes may pass this barrier and, thus, become undetectable in blood. Various cell types shed small particles upon activation an/or injury, so called extracellular vesicles (EVs). These EVs, which are shed by various cell types upon activation and/or injury, contain various proteins and are too large to travers dialyzer membranes. Their assessment requires strict and standardized collection and handling of blood samples. In previous HD research, both pre-analytical circumstances and analytic methods were insufficiently standardized, precluding solid conclusions. Both the contact between circulating blood cells and the ECC, and recurrent IDH, predispose to micro-inflammation and cell activation, which are related to morbidity and mortality. Hence, when analysed properly, the measuring of EVs might be a valuable tool to assess dialysis-induced adverse side-effects, not only in the dialyzer but also in the body, which, when occurring repeatedly, may influence survival. In a recent study, we found an increase in EVs during treatment with different dialysis modalities. However, EVs were only assessed before and after dialysis. Hence, in the present study, we aim to assess the kinetics of EVs in routine HD.

Interventions

* Dialyzers: Cordiax FX80 dialyzers; membrane material HelixonePlus (polysulfone); (Fresenius Medical Care Bad Homburg, Germany) * Dialysis machines: Baxter Gambro AK 98 (Gambro Lundia AB, Lund, Sweden; part of Baxter Healthcare Corporation) * Needles for vascular access: Nipro SafeTouch dialysis cath 1.6x25 mm (16G) or 1.9x25 mm (15G); or Nipro SafeTouch Tulip needles (15G; all Nipro Medical Europe Mechelen, Belgium) * Ultrapure dialysis fluids (less than 0.1 colony forming units/ml, less than 0.03 endotoxin units/ml) will be mixed with AC-F 219/1 or 213/4 liquid acid concentrates and BiBag dry bicarbonate concentrate. Hence, the electrolyte composition of the dialysis fluid will be: Na 138-142 mmol/L; K 2.0-3.0 mmol/L; HCO3 26-35 mmol/L; Ca 1.25-1.50 mmol/L; Mg 0.5 mmol/L; Cl 108.5-109 mmol/L; glucose 5.6 mmol/L; acetate 3 mmol/L. Dialysate flow rate will be 500 mL/min. * Anticoagulation: nadroparin.

Sponsors

Dianet Dialysis Centers
CollaboratorOTHER
Amsterdam UMC, location VUmc
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \>18 years * Stable clinical situation: free of infection, no recent admission * HD \>3 months * Haemoglobin level \>6,2 mmol/L * Residual diuresis \<200mL/24h * Willing and able to give written informed consent.

Exclusion criteria

* Active infection, malignancy, auto-immune disease, or treatment with immunosuppressive medication. * Allergy to polysulfone dialysers * Life expectancy \<3 months due to non-renal disease * Access recirculation

Design outcomes

Primary

MeasureTime frameDescription
Intradialytic change in the concentration of extracellular vesicles from specific cell types4 hours (=one dialysis treatment); assessed at the following time points: 0 minutes (start of dialysis), 30 min, 60 min, 120 min, 180 min, 235 minutesBlood cell-derived EVs: platelets: CD61+, activated platelets: CD61+/CD62p+; erythrocytes: CD235a+; leukocytes CD45+; and endothelium-derived EVs: CD144+, activated endothelium CD62e+; myocardium and endothelium-derived: Connexin-43+ will be measured at different sampling sites (sampling point 1: before the roller pump, arterial line; sampling point 2: after the rollerpump and before the dialyzer, sampling point 3: after the dialyzer, efferent line).

Secondary

MeasureTime frameDescription
Intradialytic blood pressure4 hours (=one dialysis treatment); measured 4x/hourChange in systolic and diastolic blood pressure (mmHg) during dialysis
Hematocrit (Ht)4 hours (=one dialysis treatment); measured three times (at the start (0 minutes), half way (120 minutes) and at the end (240 minutes))the volume percentage of red blood cells (RBCs) in blood
High sensitive CRP (hsCRP)4 hours (=one dialysis treatment); measured once at the start of dialysis (0 minutes)Marker of inflammation
White blood cell (WBC) count4 hours (=one dialysis treatment); measured once at the start of dialysis (0 minutes)Total white blood cell count and differential count
Platelet count4 hours (=one dialysis treatment); measured once at the start of dialysis (0 minutes)Number of platelets in blood

Countries

Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026