Skip to content

Electronic Optimization of Inspired Oxygen During Mechanical Ventilation, a Pragmatic Randomized Trial (OPTI-Oxygen)

Electronic Optimization of Inspired Oxygen During Mechanical Ventilation, a Pragmatic Randomized Trial

Status
Suspended
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05923853
Enrollment
936
Registered
2023-06-28
Start date
2024-01-15
Completion date
2026-05-01
Last updated
2025-04-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hyperoxia

Brief summary

OPTI-Oxygen is a single center, stepped wedged, cluster-randomized, un-blinded, pragmatic, comparing the use of a combined inspired oxygen (FiO2) and peripheral oxygen saturation (SpO2) titration strategy utilizing electronic health records (EHR) based electronic alerts (e-alerts) for respiratory therapists in mechanically ventilated critically ill adults. All eligible mechanically ventilated patients, FiO2 titration and SpO2 goal range will be based on the correlation between SpO2 and arterial oxygen saturation (SaO2). E-alerts will be sent in the intervention arm as reminders for FiO2 titration. In the control arm, patients will have oxygen titrated per current standard of care (SpO2=88-92%, titrate FiO2 at least every 4 hours).

Detailed description

We will conduct a single center, stepped wedged, cluster-randomized, un-blinded, pragmatic, comparing the use of a combined inspired oxygen (FiO2) and peripheral oxygen saturation (SpO2) titration strategy utilizing electronic health records (EHR) based electronic alerts (e-alerts) for respiratory therapists in mechanically ventilated critically ill adults. The participating intensive care units (ICU) will be medical, cancer, surgical (general surgery and trauma) and coronary critical care at the Ohio State University, Wexner Medical Center and James Cancer Hospital (128 beds). In this stepped wedge design, there will be nested randomization. A 12-13 bed pod within each of the 4 ICU's will be randomized as step. Each 12-13 bed pod, geographically located within a unit will serve as a cluster and transition from control to intervention will occur every 6 weeks, with an initial 2 week implementation period. All intubated patients meeting inclusion criteria in a particular cluster will be in the intervention or control group per the assignment of that cluster. In the intervention arm, arterial oxygen saturation (SaO2) and peripheral oxygen saturation (SpO2) will be initially noted. Based on the correlation between the SaO2 and SpO2 the optimal oxygenation range will be determined. Then E-alerts will be used to monitor oxygenation for patients in the intervention arm, based SpO2 values generated by the patient due to the FiO2 given to the patient through the ventilator. E-Alerts search for SpO2 and FiO2 values every minute to evaluate if they meet criteria for optimal oxygenation. If in a 45 minute period 80% of values for both SpO2 and FiO2 values are do not meet target range then an e-alert (text message) is sent to the respiratory therapy cisco phones recommending that oxygen needs to be titrated. Once an e-alert is sent, the respiratory therapist has 45 minutes for adjusting oxygen. Then the e-alert continues to monitor FiO2 and SpO2 values in this manner for every 45 minute period until the ventilator is attached to the patient. (Details in study procedures, section 5). In the control arm, FiO2 titration will be assessed by the optimal oxygenation criteria by current standard of care. This is done by following the ICU ventilator management guidelines. Per the ventilator management guidelines assessment for FiO2 titration is recommended at least once in 4 hours to maintain oxygenation with the optimal range. Treatment allocation (SpO2 and FiO2 targeted titration) will cross over to a new cluster at the conclusion of each period. Protocol adherence will be monitored. Data will be collected until hospital discharge. The study will be carried about with waiver of consent, because the target ranges studied are used as part of routine clinical care in the ICU, and are interventions to which patients would be exposed even if not participating in the study. There is clinical equipoise, i.e. have inadequate prior data to suggest the superiority of one approach over the other. Additionally, patients in the trial would be expected to receive similar oxygen therapy in an unstructured manner if they were not in the trial.

Interventions

OTHERFiO2 titration using electronic alert system

In the intervention arm, arterial oxygen saturation (SaO2) and peripheral oxygen saturation (SpO2) will be initially noted. Based on the correlation between the SaO2 and SpO2 the optimal oxygenation range will be determined. E-alerts will then be used to monitor oxygenation for patients in the intervention arm, based on SpO2 values generated by the patient due to the FiO2 given to the patient through the ventilator. Once an e-alert is sent, the respiratory therapist has 45 minutes for adjusting oxygen. Then the e-alert continues to monitor FiO2 and SpO2 values in this manner for every 45 minute period until the ventilator is attached to the patient.

Sponsors

National Heart, Lung, and Blood Institute (NHLBI)
CollaboratorNIH
Ohio State University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Investigator, Outcomes Assessor)

Masking description

Respiratory therapists and study coordinators will be unblinded. Study investigators, medical monitor and statistician will be blinded.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \>18 years * Presence of mechanical ventilation

Exclusion criteria

* Pregnancy * Prisoner status * Pneumothorax * Carbon monoxide poisoning * Hyperbaric oxygen therapy

Design outcomes

Primary

MeasureTime frameDescription
Proportion of time during mechanical ventilation spent within the target range, SpO2 of 90-94% (conservative) or SpO2 of 93-97% (liberal) at any FiO2 in respective algorithms.through study completion, average of 28-30 daysPercent time during mechanical ventilation in target range.

Secondary

MeasureTime frameDescription
Proportion of time with time with SpO2 < 90% or SpO2 < 93% in respective algorithms.through study completion, average of 28-30 daysPercent time during mechanical ventilation below target range.
Length of ICU staythrough study completion, average of 28-30 daysTotal number of days in the ICU.
Length of hospital staythrough study completion, average of 28-30 daysTotal number of days in the hospital.
Hospital mortalitythrough study completion, average of 28-30 daysDead or alive at hospital discharge.
Proportion of time with SpO2 > 94% or SpO2 > 97% with FiO2 ≤ 0.4 in respective algorithms.through study completion, average of 28-30 daysPercent time during mechanical ventilation above target range.
Vasopressor-Free Daysthrough study completion, average of 28-30 daysAlive and free from vasopressor support at day 28.
ICU-Free Daysthrough study completion, average of 28-30 daysAlive and out of the ICU at day 28.
New onset arrhythmia when SpO2<90%through study completion, average of 28-30 daysArrhythmia onset during hypoxemia.
Change to comfort care status (DNRCC) and time to DNRCC after enrollment.until hospital discharge or death befoe hospital discharge, upto 60 daysChange to comfort care status after enrollment will be recorded and analyzed as a dichotomous outcome. Time to DNRCC after enrollment will be evaluated in an exploratory nature using appropriate time-to-event models. Hospital mortality while in comfort care status will also be examined as an exploratory endpoint.
Ventilator-Free Daysthrough study completion, average of 28-30 daysAlive and free from ventilator support at day 28.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026