Mechanical Ventilation
Conditions
Brief summary
There are two cases in which the cross-sectional area of the tracheal catheter balloon does not match the cross-sectional area of the patient's airway. If the area of the tracheal catheter balloon is smaller than the cross-sectional area of the patient's airway, the pressure in the balloon reaches 30 cmH2O, and the airway cannot be completely sealed; This will increase the risk of VAP. If the area of the tracheal catheter balloon is significantly larger than the cross-sectional area of the patient's airway, and the pressure in the balloon reaches 30 cmH2O, the airway cannot be effectively sealed; The formation of wrinkles around the airbag also increases the risk of VAP in patients. Therefore, the purpose of this study is to build a risk model of airway leakage of patients' endotracheal tubes, which provides an accurate and objective assessment tool for medical staff, so that medical staff can select the endotracheal tubes purposefully and with emphasis from the beginning of the patients' endotracheal tubes, and reduce the airway leakage or airway mucosal damage of the endotracheal tubes.
Detailed description
Admission number, department, name, gender, height, and weight are obtained through the hospital's electronic medical record management system。 Tidal volume (set Tidal volume), airway peak pressure (real-time data on the ventilator screen), data collection is synchronized with the minimum cuff pressure measurement when the airway is closed.
Interventions
1. Conduct statistical analysis on general information, respiratory data, tracheal catheter data, and cross-sectional area of the patient's airway to clarify the current status of airway leakage and related influencing factors. 2. Based on multivariate logistic regression, a line chart prediction model for predicting the risk of airway leakage in patients with tracheal catheters is constructed. The clinical efficacy of the prediction model is evaluated by using the area under the ROC curve, the Calibration scatter plot, and the DCA decision line, respectively, to assess its discrimination, calibration, and clinical practicality.
Sponsors
Study design
Eligibility
Inclusion criteria
Invasive mechanical ventilation; Chest CT imaging examination within 1 year;
Exclusion criteria
Patients with pneumothorax Acute respiratory distress syndrome; Chronic Obstructive Pulmonary Disease; Multiple organ dysfunction.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Patient airway area | Within 1 year | Firstly, confirm the front position of the tracheal catheter through chest X-ray, and then manually sketch the area of interest along the outer wall of the airway using Computed Tomography to calculate the area. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Measure the minimum cuff pressure | 1min | The specific method is as follows: the patient takes a 30 ° semi recumbent position, puts a Stethoscope on the throat of the patient's trachea, inflates air into the trachea tube cuff until the air leakage sound just disappears, at this time, the value displayed by the cuff pressure gauge is the minimum cuff pressure when the airway is closed |