Skip to content

Fluid Responsiveness Evaluation by a Non-invasive Method in CHildren

Fluid Responsiveness Evaluation by a Non-invasive Method in CHildren - The FRENCH Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05919719
Acronym
FRENCH
Enrollment
21
Registered
2023-06-26
Start date
2022-02-03
Completion date
2023-02-01
Last updated
2023-06-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Circulatory Failure (Shock)

Keywords

shock, volume expansion, goal-directed fluid management, echocardiography

Brief summary

In this study, the investigators aim to validate a non-invasive marker of fluid-responsiveness in children with acute circulatory failure based on standardized abdominal compression. This would allow physicians to identify which patient could benefit from a fluid expansion, thus avoiding a potentially useless or even dangerous fluid expansion, leading to fluid overload. To this end, the investigators will evaluate the diagnostic accuracy (sensitivity and specificity) of stroke volume variation induced by standardized abdominal compression for the diagnosis of fluid responsiveness (based on the gold-standard test: significant increase in cardiac index after fluid expansion).

Detailed description

Fluid expansion is the cornerstone of acute circulatory failure treatment in children Although this therapy drastically reduced mortality, several studies in recent years have highlighted the adverse effects of excessive fluid expansion (leading to fluid overload). Currently, the search for indicators to predict fluid responsiveness is a major issue in intensive care. These indicators are based on Franck-Starling's law: if small changes in preload lead to an increase in cardiac output, then fluid responsiveness can be expected. However, in children, the only validated indicator (respiratory variability of peak aortic velocity) can only be used in the absence of any spontaneous respiratory movement, a rare situation in practice. Recently, two pediatric studies investigated a simple clinical test: hepatic or abdominal compression. This clinical maneuver, by increasing venous return via mobilization of the hepato-splanchnic reserve, induces a transient and reversible preload increase. The evaluation of the hemodynamic effects of this endogenous fluid expansion allowed, according to the authors, to accurately predict fluid responsiveness. However, several factors reduce the applicability of these results: the small number of studies on this subject, the smaller volume of fluid used than in clinical practice, and the population studied, composed almost exclusively of children in postoperative of cardiac surgery. In this study, the investigators will evaluate the diagnostic accuracy of abdominal compression for the diagnosis of fluid responsiveness in children with acute circulatory failure, hospitalized in pediatric intensive care unit (PICU) for a medical or a non-cardiac surgical condition, for whom a fluid expansion was prescribed by the physician in charge. The index test will be the stroke volume variation following a standardized abdominal compression (before fluid expansion). The gold standard test will be the variation of cardiac output between baseline and after fluid expansion, a variation \> 15% defining fluid responsiveness. In this non interventional study of diagnostic accuracy, patients will undergo an extra echocardiographic assessment, but no supplemental blood test or invasive parameters will be collected. Simple clinical parameters will be collected within 4 hours after the fluid expansion. Patients will be follow-up until PICU discharge.

Interventions

Fluid expansion will be delayed while our index test is performed. After fluid expansion, patient will undergo an echocardiographic assessment of response to fluid expansion (gold-standard). Our index test is the ΔSVi-AC: indexed percentage of stroke volume variation between baseline and during a standardized abdominal compression. Stroke volume will be assessed by transthoracic echocardiography. Patient will undergo 3 echocardiographic assessment: At baseline, During abdominal compression, After the 10 to 20ml/kg crystalloid fluid expansion Abdominal compression : a sphygmomanometer will be inflated to a pressure of less than 10 mmHg and will be applied to the center of the patient's abdomen. Then, a gentle compression on the sphygmomanometer will be performed, calibrated at 22 - 26 mmHg according to the sphygmomanometer. The echocardiographic assessments will take place between 10 and 60 seconds after the start of the compression, which will therefore last less than a minute.

Sponsors

University Hospital, Bordeaux
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Minutes to 14 Years
Healthy volunteers
No

Inclusion criteria

* Age lower than 15 years old * Prescription of a 10 to 20ml/kg crystalloid fluid expansion by the physician in charge * Acute circulatory failure defined by the association of an A criteria (increase of heart rate more than two standard deviation for the age, decrease of systolic or mean blood pressure more than two standard deviation for ) and a B criteria (lactate more than 2 mmol/L, oliguria less than 1mL/kg/h, a capillary filling time more than 3 seconds, mottling) * Patient hospitalized in PICU

Exclusion criteria

* Prematurity (term below 37 gestational week). * Acute cardiogenic pulmonary edema * Hemodynamic instability making the delay necessary for abdominal compression and ultrasonography dangerous for the patient * Non corrected congenital cardiopathy, or inferior to 15 days postoperative. * Intra-abdominal hypertension or painful abdominal palpation * Abdominal surgery in the last 15 days * Supine position contraindicated or deleterious * No investigator available to assess ultrasonographic measures * Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracy of the index test (ΔSVi-AC) for the diagnosis of fluid responsivenessafter abdominal compression, 30 minutes to 4 hours after baselineDiagnostic accuracy of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness, defined by an increase of cardiac output \> 15% after fluid expansion (ΔCO-FE \> 15%, gold-standard test) Index test (ΔSVi-AC) will be calculated as the difference between Stroke Volume (SV) after abdominal compression and SV at baseline, divided by SV at baseline (%). SV will be measured by echocardiographic assessment. Gold-standard test (ΔCO-FE) will be calculated as the difference between CO after fluid expansion and CO at baseline, divided by CO at baseline (%). CO will be measured by echocardiographic assessment.

Secondary

MeasureTime frameDescription
Association between elevated ΔSVi-AC and capillary filling time (sec) -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and capillary filling time (sec). Normal value: \< 3 seconds.
Association between elevated ΔSVi-AC and Heart rate (bpm). -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and Heart rate (bpm). Normal value: \< 2 standard deviation for the age
Association between elevated ΔSVi-AC and Heart rate (bpm). -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and Heart rate (bpm). Normal value: \< 2 standard deviation for the age
Association between elevated ΔSVi-AC and Mean blood pressure (mmHg). -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and Mean blood pressure (mmHg). Normal value: \< 2 standard deviation for the age
Association between elevated ΔSVi-AC and Mean blood pressure (mmHg). -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and Mean blood pressure (mmHg). Normal value: \< 2 standard deviation for the age
Association between elevated ΔSVi-AC and capillary filling time (sec) -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and capillary filling time (sec). Normal value: \< 3 seconds
Association between elevated ΔSVi-AC and urine output (ml/kg/h). -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and Urine output (ml/kg/h). Normal value: \> 1ml/kg/h.
Association between elevated ΔSVi-AC and Blood lactate (mmol/L). -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and Blood lactate (mmol/L). Normal value: \< 2mmol/L
Association between elevated ΔSVi-AC and Blood lactate (mmol/L). -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and Blood lactate (mmol/L). Normal value: \< 2mmol/L
Association between elevated ΔSVi-AC and Central venous oxygen saturation (%). -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and Central venous oxygen saturation (%). Normal value: \>70%
Association between elevated ΔSVi-AC and Central venous oxygen saturation (%). -after abdominal compressionafter abdominal compression, 30 minutes to 4 hours after baselineAssociation between elevated ΔSVi-AC and Central venous oxygen saturation (%). Normal value: \>70%
Association between elevated ΔSVi-AC and urine output (ml/kg/h). -Baselineat baseline (before fluid expansion)Association between elevated ΔSVi-AC and Urine output (ml/kg/h). Normal value: \> 1ml/kg/h.

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026