Skip to content

Continuous Central Venous Oxygen Saturation Measurement as a Tool to Predict Hemodynamic Instability Related to Renal Replacement Therapy in Critically Ill Patients

Continuous Central Venous Oxygen Saturation Measurement as a Tool to Predict Hemodynamic Instability Related to Renal Replacement Therapy in Critically Ill Patients

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05897840
Acronym
SoVHIRR
Enrollment
100
Registered
2023-06-09
Start date
2023-09-04
Completion date
2024-12-31
Last updated
2023-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Kidney Injury

Keywords

Hemodynamic instability related to renal replacement therapy, Continuous mixed venous central oxygen saturation, Intensive Care Unit, Sensibility, Specificity, Acute Kidney Injury, Renal replacement therapy, Intradialytic hypotension, Cardiac output

Brief summary

Acute kidney injury (AKI) is common in intensive care unit (ICU) and inducing a high morbidity and mortality. In severe forms of AKI (more than 25% of AKI patients admitted to the ICU), renal replacement therapy (RRT) is often necessary. Although RRT is a cornerstone of therapy, it can lead to serious adverse effects, such as intradialytic arterial hypotension. Indeed, arterial hypotension during the session - intra-dialytic arterial hypotension (IDH) - occurs frequently complication and so regardless of the RRT modality used. Its occurrence may worsen significantly the outcome as previously reported. It is therefore of parmount importance to prevent such an adverse effect. The investigators hypothesize that a decrease in the central venous oxygen saturation (SvcO2) measured related to a decreased cardiac output could precede the onset of IDH. The aim of this study is collect IDH in AKI patients and to measure continuously SvcO2 during RRT session in order to investigate its role in predicting IDH.

Detailed description

In ICU settings, about 25% of AKI patients underwent RRT. RRT leads to certain complications, the most frequent and severe of which is IDH. The frequency of IDH varies from 10 to 70% and from 19 to 43% in intermittent and continuous RRT respectively. The occurrence of IDH worsens the prognosis of critically ill patients. It may impair the recovery of renal function and is associated with increased mortality. Thus, early detection of IDH requires the development of preventive strategies and the implementation of adapted curative therapies. IDH results from several mechanisms. The main mechanisms involved is hypovolemia leading to cardiac dysfunction, but also cardiac dysfunction not related to hypovolemia. The identification of tools correlated with cardiac output could allow early prediction of IDH. Yet, no tool has been evaluated to predict the occurrence of IDH. Central venous oxygen saturation (SvcO2) is a reflection of the balance between systemic O2 transport and tissue O2 consumption and thus is the indicator of cardiac output. A decrease in cardiac output leads to a decrease in SvcO2 to enhance O2 transport and to maintain arterial pressure. Assuming that O2 extraction is constant, SvcO2 would then be a surrogate for cardiac output. A decrease in SvcO2 may reflect a decrease in cardiac output before IDH occurs. There are very few data in the literature evaluating changes in cardiac output during an RRT session. Continuous measurement of SvcO2, a minimally invasive and indirect marker of cardiac output, during an RRT session has never been reported to predict IDH. The investigators hypothesize that a decrease in SvcO2, indicative of decreased cardiac output, should precede the onset of IDH. In order to evaluate this hypothesis, the investigators intend to measure continuous SvcO2 and continuous cardiac output during the first three RRT sessions, regardless of the RRT modality. The investigators will assess the performance of SvcO2 values and other invasive hemodynamic parameters in predicting the occurrence of IDH using ROC curves. Once the composite score has been constructed, an optimal threshold will be determined using Youden's J statistic. Determination of the 95% confidence interval (95% CI), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Comparison of areas under the curve using Delong's non-parametric approach. Patients will be monitored until they are discharged from intensive care, intensive care, death or D28 max.

Interventions

DEVICEFiber-optic probe CeVOX

Installation of the fiber-optic probe within the existing central venous catheter for continuous monitoring of SvcO2

Sponsors

University Hospital, Montpellier
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Intervention model description

Assessing the ability of continuously measured SvcO2 to predict the occurrence of IDH in critical patients suffering from an AKI for which RRT is necessary.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Critically ill patients requiring blood pressure monitoring * Severe AKI treated by RRT * Hemodynamic stability prior to initiation of RRT * Patients aged above 18 years

Exclusion criteria

* Pregnancy * Major under tutorship or curatorship * Refusal of the patient or trusted person/family (if present) to sign the informed consent or to confirm participation in the case of emergency inclusion * Patient is not beneficiary or affiliated with a social security plan * Contraindication to placement of a venous catheter in the superior vena cava territory: thrombosis of the superior vena cava, thrombosis of the jugular and subclavian veins * Chronic end-stage renal failure on chronic dialysis

Design outcomes

Primary

MeasureTime frameDescription
Venous oxygen saturation measurement1-28 daysVenous oxygen saturation measured continuously during the RRT session in the critically ill patient. Intradialytic hypotension is defined as the occurrence of a decrease in systolic blood pressure below 90mmHg and/or a decrease in mean arterial pressure below 65mmHg that warrants therapeutic intervention (vascular filling, introduction or increase in the dose of vasopressor by more than 25% to maintain satisfactory blood pressure, discontinuation of ultrafiltration) during the RRT session.

Secondary

MeasureTime frameDescription
IDH corrective measures1-28 daysVascular filling, introduction or increase of the dose of vasopressor by more than 25% to maintain satisfactory blood pressure, discontinuation of ultrafiltration
Cardiac output variation1-28 daysVariations in cardiac output measured continuously during the RRT session
Number of IDH during a RRT session1-28 daysNumber of IDH during a RRT session
RRT duration1-28 daysRRT duration
Mortality in the ICU1-28 daysMortality in the ICU
Pulse pressure variation1-28 daysValue of the pulse pressure variation measured continuously during the RRT session

Countries

France

Contacts

Primary ContactEddine BENDIAB, Dr
e-bendiab@chu-montpellier.fr0467332495
Backup ContactKada KLOUCHE, Pr
k-klouche@chu-montpellier.fr0467338441

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026