Retrospective Study on Radiological Factors Predictive of Psoas Impingement

Retrospective Study on Radiological Factors Predictive of Symptomatic Psoas Impingement Development in Protruding Cups in Primary Hip Arthroplasty

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05893823
Enrollment
52
Registered
2023-06-08
Start date
2022-06-06
Completion date
2025-06-14
Last updated
2025-07-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hip Impingement Syndrome, Prosthetic Complication

Keywords

Iliopsoas Impingement, Overhanging Cup

Brief summary

The purpose of this study is to identify radiological factors on TC of the hip that could lead to prediction of development of symptomatic psoas impingement in patients with protruding acetabular cup after primary total hip arthroplasty.

Interventions

DIAGNOSTIC_TESTPelvis CT scan

Post-THA hip pelvis CT scan execution for pain, noise or THA planning for the controlateral hip, with identification of acetabular cup protrusion. Comparation of cases and controls to identify radiological factors that could potentially lead to symptomatic psoas impingement prediction.

Sponsors

Istituto Ortopedico Rizzoli
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Primary total hip arthroplasty * Execution of a postoperative Ct scan for pain, noises or planning of the contralateral THA * 5 years minimum follow-up for the control group, tenotomy of the iliopsoas muscle in the cases group * Complete clinical and radiological data

Exclusion criteria

* Patient's refusal to participate * Non adequate Ct scans or made for periprosthetic fractures, component mobilization, periprosthetic infection or wearing of the prosthesis * Incomplete clinical and radiological data * Inadequate follow-up or regression of the iliopsoas impingement symptoms with non-operative treatment

Design outcomes

Primary

MeasureTime frameDescription
Acetabular Cup Inclinationat baseline (day 0)The angle between the tangent to the cup opening and the interteardrop line in the frontal plane
Femoral Offsetat baseline (day 0)The distance between the center of rotation and the femoral axis in the frontal plane
Acetabular Offsetat baseline (day 0)The distance between the center of rotation and the Kohler line in the frontal plane
Eccentric Reamingat baseline (day 0)The distance between the native hip center of rotation and the acetabular cup center of rotation in the axial plane
Acetabular Cup Antiversionat baseline (day 0)The angle between the tangent to the cup opening and the tangent to the posterior ischial spines in the axial plane

Countries

Italy

Participant flow

Participants by arm

ArmCount
Cases
Patients that have symptomatic psoas impingement in a protruding acetabular cup documented by a Pelvis CT scan
35
Controls
Asymptomatic patients with a protruding acetabular cup documented by a Pelvis CT scan
17
Total52

Baseline characteristics

CharacteristicCasesControlsTotal
Age, Continuous53.5 years
STANDARD_DEVIATION 11.8
54.1 years
STANDARD_DEVIATION 15.3
53.7 years
STANDARD_DEVIATION 12.9
Cup protrusion
Cup protrusion on frontal plane
5.9 millimeters
STANDARD_DEVIATION 4.8
7.6 millimeters
STANDARD_DEVIATION 3.4
6.4 millimeters
STANDARD_DEVIATION 4.5
Cup protrusion
Cup protrusion on sagital plane
12.8 millimeters
STANDARD_DEVIATION 5.6
14.9 millimeters
STANDARD_DEVIATION 5.4
13.5 millimeters
STANDARD_DEVIATION 5.6
Race and Ethnicity Not Collected0 Participants
Sex: Female, Male
Female
20 Participants9 Participants29 Participants
Sex: Female, Male
Male
15 Participants8 Participants23 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 350 / 17
other
Total, other adverse events
0 / 350 / 17
serious
Total, serious adverse events
0 / 350 / 17

Outcome results

Primary

Acetabular Cup Antiversion

The angle between the tangent to the cup opening and the tangent to the posterior ischial spines in the axial plane

Time frame: at baseline (day 0)

ArmMeasureValue (MEAN)Dispersion
CasesAcetabular Cup Antiversion19.8 degreeStandard Deviation 9.5
ControlsAcetabular Cup Antiversion11.5 degreeStandard Deviation 9.4
Primary

Acetabular Cup Inclination

The angle between the tangent to the cup opening and the interteardrop line in the frontal plane

Time frame: at baseline (day 0)

ArmMeasureValue (MEAN)Dispersion
CasesAcetabular Cup Inclination41.8 degreeStandard Deviation 6.9
ControlsAcetabular Cup Inclination43.5 degreeStandard Deviation 5.8
Primary

Acetabular Offset

The distance between the center of rotation and the Kohler line in the frontal plane

Time frame: at baseline (day 0)

ArmMeasureValue (MEAN)Dispersion
CasesAcetabular Offset32.0 millimetersStandard Deviation 4.5
ControlsAcetabular Offset33.8 millimetersStandard Deviation 5.6
Primary

Eccentric Reaming

The distance between the native hip center of rotation and the acetabular cup center of rotation in the axial plane

Time frame: at baseline (day 0)

ArmMeasureValue (MEAN)Dispersion
CasesEccentric Reaming1.8 millimetersStandard Deviation 4
ControlsEccentric Reaming0.8 millimetersStandard Deviation 3.7
Primary

Femoral Offset

The distance between the center of rotation and the femoral axis in the frontal plane

Time frame: at baseline (day 0)

ArmMeasureValue (MEAN)Dispersion
CasesFemoral Offset40.2 millimetersStandard Deviation 5.8
ControlsFemoral Offset38.4 millimetersStandard Deviation 7.7

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026