What is the Efficiency When Comparing Active Sentry at Low IOP vs Ozil at High IOP?

What is the Efficiency When Comparing Active Sentry at Low IOP vs Ozil at High IOP?

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05868772
Enrollment
36
Registered
2023-05-22
Start date
2023-05-16
Completion date
2024-04-19
Last updated
2025-04-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Brief summary

The objective is to assess the efficiency of the Active Sentry handpiece at low intraocular pressure (IOP) compared with the Ozil at high IOP.

Detailed description

This study is a single site, single-masked, randomized, prospective, contralateral eye study of the efficiency of the Active Sentry handpiece at low IOP compared with the Ozil at high IOP.

Interventions

DEVICEActive Sentry Handpiece

With low IOP settings

DEVICEOzil Handpiece

With high IOP settings.

Sponsors

Sengi
CollaboratorINDUSTRY
Cataract and Laser Institute of Southern Oregon
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
50 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

Subjects are eligible for the study if they meet the following criteria: Note: Ocular criteria must be met in both eyes. * Be eligible to undergo sequential bilateral uncomplicated cataract surgery. * Undergo uneventful cataract surgery. * Gender: Males and Females. * Both eyes must have same grade of cataract. * Willing and able to provide written informed consent for participation in the study. * Willing and able to comply with scheduled visits and other study procedures.

Exclusion criteria

If any of the following

Design outcomes

Primary

MeasureTime frame
Total Aspiration TimeDay of surgery (Day 0)

Secondary

MeasureTime frame
Total Fluid VolumeDay of surgery (Day 0)
Total Phaco TimeDay of surgery (Day 0)
Central Corneal Thickness1 week postoperative

Other

MeasureTime frameDescription
Cumulative Dissipated Energy (CDE)Day of surgery (Day 0)CDE is the amount of ultrasound energy used to remove a cataractous lens. CDE is the power and time of torsional and longitudinal ultrasound delivery modes. It is not expressed in standard units, but is generally unitless. CDE is calculated by the Centurion® Vision System automatically. A lower value is indicative of lower energy used in the eye.

Countries

United States

Participant flow

Participants by arm

ArmCount
Overall (All Participants)
Contralateral eye study, flow includes all participants
36
Total36

Baseline characteristics

CharacteristicOverall (All Participants)
Age, Continuous71.3 years
STANDARD_DEVIATION 6.7
Race and Ethnicity Not Collected— Participants
Sex: Female, Male
Female
19 Participants
Sex: Female, Male
Male
17 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 360 / 36
other
Total, other adverse events
1 / 362 / 36
serious
Total, serious adverse events
0 / 360 / 36

Outcome results

Primary

Total Aspiration Time

Time frame: Day of surgery (Day 0)

ArmMeasureValue (MEAN)Dispersion
Active Sentry HandpieceTotal Aspiration Time90.1 secondsStandard Deviation 16.4
Ozil HandpieceTotal Aspiration Time85.1 secondsStandard Deviation 17
Secondary

Central Corneal Thickness

Time frame: 1 week postoperative

ArmMeasureValue (MEAN)Dispersion
Active Sentry HandpieceCentral Corneal Thickness554.9 umStandard Deviation 27.6
Ozil HandpieceCentral Corneal Thickness555.5 umStandard Deviation 28.8
Secondary

Total Fluid Volume

Time frame: Day of surgery (Day 0)

ArmMeasureValue (MEAN)Dispersion
Active Sentry HandpieceTotal Fluid Volume32.8 mLStandard Deviation 4.6
Ozil HandpieceTotal Fluid Volume33.8 mLStandard Deviation 6
Secondary

Total Phaco Time

Time frame: Day of surgery (Day 0)

ArmMeasureValue (MEAN)Dispersion
Active Sentry HandpieceTotal Phaco Time29.5 secondsStandard Deviation 7.3
Ozil HandpieceTotal Phaco Time31.0 secondsStandard Deviation 7.4
Other Pre-specified

Cumulative Dissipated Energy (CDE)

CDE is the amount of ultrasound energy used to remove a cataractous lens. CDE is the power and time of torsional and longitudinal ultrasound delivery modes. It is not expressed in standard units, but is generally unitless. CDE is calculated by the Centurion® Vision System automatically. A lower value is indicative of lower energy used in the eye.

Time frame: Day of surgery (Day 0)

ArmMeasureValue (MEAN)Dispersion
Active Sentry HandpieceCumulative Dissipated Energy (CDE)5.0 unitlessStandard Deviation 1.9
Ozil HandpieceCumulative Dissipated Energy (CDE)5.2 unitlessStandard Deviation 1.7