Prospective Cardiac Ultrasound Imaging Study With Demonstrator

Prospective Cardiac Ultrasound Imaging Study With Demonstrator

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05850741
Acronym
CARDIOKIT
Enrollment
24
Registered
2023-05-09
Start date
2021-06-04
Completion date
2022-02-03
Last updated
2023-05-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Tachycardia

Keywords

artificial intelligence, cardiac radioablation, echocardiography, motion monitoring, ventricular arrhythmia

Brief summary

The Prospective Cardiac Ultrasound Imaging Study is a single center, single arm, feasibility study. The study aims at collecting cardiac ultrasound data from patients diagnosed with ventricular tachycardia, during rest and short breath hold sequences. This study is part of the engineering studies linked to the CardioKit-Minimum Viable Product project. The CardioKit prototype used in the study can monitor cyclical heart-beat motion, cyclical respiratory motion and non-cyclical heart position changes while the patient is lying in supine position.

Detailed description

The research will analyse the ultrasound image data quality, especially investigating the ability of the prototype system to automatically and correctly interpret ultrasound images and artifact issues which may arise from age, body composition, mechanical valves, leads from implanted devices, or other implants. The study will establish if it is appropriate to develop a new medical device supporting automated cardiac ultrasound image interpretation during non-invasive cardiac procedures, i.e. ventricular tachycardia stereotactic radioablation. This early research protocol did collect data from 24 adult patients. The data were not used for diagnostic nor treatment purposes and the protocol's procedure duration was limited to one hour, hence the research was considered of very limited risk for the participants. The research will provide a Proof-of-Concept for a Medical Device to benefit patients with ventricular tachycardia and other cardiac pathologies in the future.

Interventions

DEVICECardiokit

The CardioKit prototype used in the study can monitor cyclical heart-beat motion, cyclical respiratory motion and non-cyclical heart position changes while the patient is lying in supine position.

Sponsors

Fondazione IRCCS Policlinico San Matteo di Pavia
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

1. Patient with history of ventricular tachycardia 2. Over 18 years old 3. Ability and willingness to provide written informed consent

Exclusion criteria

1\. Patient in arrhythmic storm

Design outcomes

Primary

MeasureTime frameDescription
Image quality in terms of allowing a correct identification of the phase of the cardiac cycle by the prototype software.BaselineThe primary endpoint was defined as the percentage of patients able to obtain a positive result in a multi parametric score of image quality, consisting of: Score = 1: average phase error per patient, defined as the difference between the phase of the cardiac cycle identified by the algorithm and the one evaluated by the ECG reference \<0.1. Score = 0: average phase error per patient ≥0.1. For each patient, scoring was done for each imaging view (i.e., parasternal and apical). If the score was 2 (at least 1 point in A or B and 1 point in C or D) or greater for at least one of the imaging views, the outcome was considered as positive. The final result is the proportion of patients (in %) with a positive outcome, defined as the number of patients with a positive evaluation divided by the total number of patients x 100.
Image quality in terms of allowing a correct measurement of the heart displacement (mainly due to respiratory motion) by the prototype software.BaselineThe primary endpoint was defined as the percentage of patients able to obtain a positive result in a multi parametric score of image quality, consisting of: Score = 1: maximum excursion calculated by the algorithm \<30 mm with a total 3D error in the calculation of the displacement \<3 mm. Score = 0: either maximum excursion calculated by the algorithm ≥30 mm or total 3D error in the calculation of the displacement ≥3 mm (or both). For each patient, scoring was done for each imaging view (i.e., parasternal and apical). If the score was 2 (at least 1 point in A or B and 1 point in C or D) or greater for at least one of the imaging views, the outcome was considered as positive. The final result is the proportion of patients (in %) with a positive outcome, defined as the number of patients with a positive evaluation divided by the total number of patients x 100.
Image quality in terms of the ability to distinguish typical cardiac structures, as assessed visually by the clinical operator.BaselineThe primary endpoint was defined as the percentage of patients able to obtain a positive result in a multi parametric score of image quality, consisting of: Score = 1: ability to identify visually by an experienced operator in the acquired image at least one of the following structures: left ventricular free wall, interventricular septum, mitral valve, or aortic valve. Score = 0: inability to identify at least one of these structures. For each patient, scoring was done for each imaging view (i.e., parasternal and apical). If the score was 2 (at least 1 point in A or B and 1 point in C or D) or greater for at least one of the imaging views, the outcome was considered as positive. The final result is the proportion of patients (in %) with a positive outcome, defined as the number of patients with a positive evaluation divided by the total number of patients x 100.
Image quality in terms of the stability of the image throughout the respiration cycle, as assessed visually by the clinical operator.BaselineThe primary endpoint was defined as the percentage of patients able to obtain a positive result in a multi parametric score of image quality, consisting of: Score = 1: persistence of cardiac structures within the echocardiographic image during respiratory motion. Score = 0: disappearance of cardiac structures from the echocardiographic image during respiratory motion. For each patient, scoring was done for each imaging view (i.e., parasternal and apical). If the score was 2 (at least 1 point in A or B and 1 point in C or D) or greater for at least one of the imaging views, the outcome was considered as positive. The final result is the proportion of patients (in %) with a positive outcome, defined as the number of patients with a positive evaluation divided by the total number of patients x 100.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026